•added 2012/02/03 12:00 a.m.•3 views

CVE-2011-4509: Undefined Security Weakness

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

10CVSS5.9AI score0.01975EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2012/02/03 12:00 a.m.•5 views

CVE-2011-4513: Undefined Security Weakness

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file,...

10CVSS6.6AI score0.04776EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2012/02/03 12:00 a.m.•5 views

CVE-2011-4511: Improper Neutralization of Input During Web Page Generation

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS6AI score0.0142EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•4 views

PT-2012-1896

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 before SP3 Siemens WinCC V11 aka TIA portal versions prior to SP2 Update 1 Siemens TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels affected versions not specified Siemens WinCC...

5CVSS0.0161EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2012/02/03 12:00 a.m.•3 views

PT-2012-1980

Name of the Vulnerable Software and Affected Versions Siemens WinCC flexible versions 2004 through 2008 WinCC V11 aka TIA portal TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels WinCC V11 Runtime Advanced WinCC flexible Runtime Description The issue allows remote attackers to caus...

7.1CVSS0.07259EPSS
SaveExploits1References10
Kaspersky
Kaspersky
•added 2012/01/24 12:00 a.m.•78 views

KLA10394 Multiple vulnerabilities in Siemens

Multiple critical vulnerabilities have been found in Siemens products. Malicious users can exploit these vulnerabilities to read & modify arbitrary files, cause denial of service, execute arbitrary code, bypass authentication, obtain access and inject arbitrary HTTP headers. Below is a complete...

10CVSS8.4AI score0.12105EPSS
SaveExploits1References5
OpenVAS
OpenVAS
•added 2011/12/23 12:00 a.m.•75 views

Multiple Siemens SIMATIC Products Authentication Bypass Vulnerabilities

Multiple Siemens SIMATIC products are affected by vulnerabilities that allow attackers to bypass authentication. SPDX-FileCopyrightText: 2011 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders...

10CVSS6.7AI score0.02979EPSS
SaveExploits0References3
OpenVAS
OpenVAS
•added 2011/12/23 12:00 a.m.•51 views

Multiple Siemens SIMATIC Products Authentication Bypass Vulnerabilities

Multiple Siemens SIMATIC products are affected by vulnerabilities that allow attackers to bypass authentication. An attacker can exploit these issues to bypass intended security restrictions and gain access to the affected application. Successfully exploiting these issues may lead to further...

10CVSS0.4AI score0.02979EPSS
SaveExploits0References5
securityvulns
securityvulns
•added 2011/12/05 12:00 a.m.•38 views

Siemens SIMATIC WinCC flexible multiple security vulnerabilities

HmiLoad and miniweb multiple security vulnerabilities...

1.6AI score
SaveExploits0References1Affected Software1
securityvulns
securityvulns
•added 2011/12/05 12:00 a.m.•90 views

Vulnerabilities in Siemens SIMATIC WinCC flexible 2008 SP2

Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms: Windows Bugs: A HmiLoad strings sta...

1.6AI score
SaveExploits0
Exploit DB
Exploit DB
•added 2011/11/28 12:00 a.m.•84 views

Siemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities

Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms: Windows Bugs: A HmiLoad strings sta...

9.3CVSS5.2AI score0.13841EPSS
SaveExploits1
exploitpack
exploitpack
•added 2011/11/28 12:00 a.m.•50 views

Siemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities

Siemens SIMATIC WinCC Flexible Runtime - Multiple Vulnerabilities Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2...

0.5AI score
SaveExploits0
ThreatPost
ThreatPost
•added 2011/11/22 5:07 p.m.•30 views

Was The Three Character Password Used To Hack South Houston's Water Treatment Plant A Siemens Default?

Siemens said on Tuesday that it is working with the U.S. Department of Homeland Security to investigate a cyber intrusion into a water treatment plant in South Houston, Texas, but couldn’t confirm that a default, three digit password hard coded into an application used to control the company’s...

8.6AI score
SaveExploits0References5
ThreatPost
ThreatPost
•added 2011/11/20 8:42 p.m.•14 views

Hacker Says Texas Town Used Three Character Password To Secure Internet Facing SCADA System

In an e-mail interview with Threatpost, the hacker who compromised software used to manage water infrastructure for South Houston, Texas, said the district had HMI human machine interface software used to manage water and sewage infrastructure accessible to the Internet and used a password that w...

0.9AI score
SaveExploits0References5
ICS
ICS
•added 2011/09/24 6:00 a.m.•94 views

Siemens Simatic HMI Authentication Vulnerabilities

Overview ICS-CERT is aware of a public report by independent security researchers Billy Rios and Terry McCorkle concerning authentication bypass vulnerabilities affecting Siemens SIMATIC HMI products which are supervisory control and data acquisition/human-machine interface SCADA/HMI products...

10CVSS7.8AI score0.02979EPSS
SaveExploits0References10
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2011/09/15 12:00 a.m.•5 views

CVE-2011-3321: Improper Restriction of Operations within the Bounds of a Memory Buffer

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC TIA Portal Runtime Advanced, allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted packet to TCP...

9.3CVSS6.6AI score0.0707EPSS
SaveExploits0References2
ICS
ICS
•added 2011/06/10 12:00 a.m.•17 views

Siemens SIMATIC S7-1200 CPU V1/V2 Devices

SUMMARY SIMATIC S7-1200 CPU V1/V2 controllers contain two vulnerabilities that could allow an unauthenticated remote attacker - to trigger functions by record and playback of legitimate network communication, or - to place the controller in stop/defect state by causing a communications error...

7.2AI score
SaveExploits0References10
ThreatPost
ThreatPost
•added 2011/05/23 4:53 p.m.•19 views

Metasploit Holding On Siemens Exploits

UPDATE: A week after a security researcher decided to cancel a technical discussion of security holes in industrial control software from Siemens, Inc., public exploits for the vulnerabilities are on hold while the company works to shore up systems running its Simatic programmable logic controlle...

7.5AI score
SaveExploits0References4
ThreatPost
ThreatPost
•added 2011/05/19 4:12 p.m.•15 views

SCADA Holes Allowed Remote Takedown of Siemens Systems

Security researcher Dillon Beresford decided not to present a talk at the TakedownCon in Dallas on Thursday, citing concerns about mayhem that could have resulted. But in an e-mail, he told Threatpost that the vulnerabilities could allow remote attackers to start or stop Siemens Programmable Logi...

0.5AI score
SaveExploits0References5
CVE
CVE
•added 2010/07/22 10:00 a.m.•442 views

CVE-2010-2772

CVE-2010-2772 affects Siemens SIMATIC WinCC and SIMATIC PCS 7: a security bypass via default hard-coded SQL credentials allows remote attackers to access the backend database with administrative-like access. The vulnerability is tied to use of default credentials in the WinCC SQL server, permitti...

7.8CVSS7.2AI score0.0055EPSS