Lucene search
+L

4647 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2015/02/18 12:00 a.m.•7 views

CVE-2015-1358: Undefined Security Weakness

The remote-management module in the 1 Multi Panels, 2 Comfort Panels, and 3 RT Advanced functionality in Siemens SIMATIC WinCC TIA Portal before 13 SP1 and in the 4 panels and 5 runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit,...

5CVSS5.9AI score0.02693EPSS
SaveExploits0References2
ThreatPost
ThreatPost
•added 2015/01/23 1:45 p.m.•13 views

Siemens Fixes Redirect Vulnerability in SIMATIC PLC

Siemens has patched a web vulnerability in its SIMATIC PLC family of products that could have led unsuspecting users to malicious sites. According to an advisory on the Industrial Control Systems Cyber Emergency Response Team‘s ICS-CERT site Thursday, the bug was an open redirect vulnerability th...

0.1AI score
SaveExploits0References2
CNVD
CNVD
•added 2015/01/22 12:00 a.m.•17 views

Siemens SIMATIC S7-1200 Open Redirect Vulnerability

The Siemens SIMATIC S7-1200 is a modular PLC controller. An open redirection vulnerability exists in integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware prior to version 4.1, which allows remote attackers to redirect a user to an arbitrary web site via an unspecified vector...

4.3CVSS6.8AI score0.01493EPSS
SaveExploits0References1
CVE
CVE
•added 2015/01/21 5:00 p.m.•72 views

CVE-2015-1048

CVE-2015-1048 affects Siemens SIMATIC S7-1200 CPU family with firmware prior to 4.1. The vulnerability is an open redirect in the integrated web server that could allow remote attackers to redirect users to arbitrary sites, enabling phishing attempts via unspecified vectors. Public sources (NVD, ...

4.3CVSS7AI score0.01493EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2015/01/21 12:00 a.m.•6 views

CVE-2015-1048: Undefined Security Weakness

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors...

4.3CVSS6AI score0.01493EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2015/01/15 12:00 a.m.•23 views

PT-2016-14: Information Disclosure in Siemens SIMATIC STEP 7 (TIA Portal)

The specialists of the Positive Research center have detected an Information Disclosure vulnerability in Siemens SIMATIC STEP 7 TIA Portal. Siemens SIMATIC STEP 7 TIA Portal uses an improper format for managing TIA project files during version updates, which makes it easier for local users to...

2.5CVSS3.3AI score0.00332EPSS
SaveExploits0References4
CNVD
CNVD
•added 2015/01/15 12:00 a.m.•22 views

Siemens SIMATIC WinCC Sm@rtClient app Information Disclosure Vulnerability

Siemens SIMATIC WinCC is the monitoring control and data acquisition SCADA and HMI system. An information disclosure vulnerability exists in Siemens SIMATIC WinCC Sm@rtClient app versions prior to 1.0.2, which allows an attacker to discover Sm@rtServer credentials by exploiting an error in the...

1.9CVSS6.3AI score0.00357EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2015/01/15 12:00 a.m.•20 views

PT-2016-13: Information Disclosure in Siemens SIMATIC STEP 7 (TIA Portal)

The specialists of the Positive Research center have detected an Information Disclosure vulnerability in Siemens SIMATIC STEP 7 TIA Portal. The vulnerability improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information. How to f...

4.7CVSS4.4AI score0.00297EPSS
SaveExploits0References4
CNVD
CNVD
•added 2015/01/15 12:00 a.m.•19 views

Siemens SIMATIC WinCC Sm@rtClient app information disclosure vulnerability (CNVD-2015-00426)

Siemens SIMATIC WinCC is the monitoring control and data acquisition SCADA and HMI system. An information disclosure vulnerability exists in the Siemens SIMATIC WinCC Sm@rtClient app prior to version 1.0.2, which allows an attacker to extract passwords from srage via an unspecified vector...

2.1CVSS6.4AI score0.00382EPSS
SaveExploits0References1
NVD
NVD
•added 2015/01/14 11:59 a.m.•30 views

CVE-2014-5233

The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism...

1.9CVSS6.2AI score0.00357EPSS
SaveExploits0References2
Prion
Prion
•added 2015/01/14 11:59 a.m.•26 views

Code injection

The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism...

1.9CVSS6.7AI score0.00357EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2015/01/14 11:00 a.m.•63 views

CVE-2014-5233

Siemens SIMATIC WinCC Sm@rtClient for iOS (pre-1.0.2) has an information-credential flaw: an error in the credential-processing/handling allows a physically proximate attacker with local access to extract Sm@rtServer credentials. The issue is tied to the app’s credential-storage/processing mechan...

1.9CVSS6.4AI score0.00357EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2015/01/14 11:00 a.m.•62 views

CVE-2014-5232

Siemens SIMATIC WinCC Sm@rtClient for iOS is vulnerable prior to version 1.0.2 due to insufficiently protected credentials and improper authentication. When the app resumes from the background, an attacker with local access could bypass the required application password, potentially gaining acces...

1.9CVSS6.2AI score0.00355EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2015/01/14 11:00 a.m.•62 views

CVE-2014-5231

Siemens SIMATIC WinCC Sm@rtClient for iOS (pre-1.0.2) is affected by CVE-2014-5231. The issue stems from Insufficiently Protected Credentials (CWE-522): the app stores its password in storage in a way that could allow a local attacker with physical access to extract it. The ICS advisory notes loc...

2.1CVSS6.5AI score0.00382EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2015/01/14 12:00 a.m.•6 views

CVE-2014-5233: Exposure of Sensitive Information to an Unauthorized Actor

The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism...

1.9CVSS5.8AI score0.00357EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2015/01/14 12:00 a.m.•4 views

CVE-2014-5231: Exposure of Sensitive Information to an Unauthorized Actor

The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors...

2.1CVSS5.8AI score0.00382EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2015/01/14 12:00 a.m.•5 views

CVE-2014-5232: Undefined Security Weakness

The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state...

1.9CVSS5.8AI score0.00355EPSS
SaveExploits0References2
ICS
ICS
•added 2015/01/10 7:00 a.m.•86 views

Siemens SIMATIC HMI Devices Vulnerabilities (Update E)

OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-15-099-01D Siemens SIMATIC HMI Devices Vulnerabilities that was published September 10, 2015, on the NCCIC/ICS‑CERT web site. Siemens has identified three vulnerabilities in its SIMATIC HMI devices. These...

6.8CVSS5.7AI score0.02134EPSS
SaveExploits0References10
NVD
NVD
•added 2014/11/26 11:59 a.m.•33 views

CVE-2014-8552

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets...

5CVSS6.5AI score0.02047EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2014/11/26 11:00 a.m.•41 views

CVE-2014-8552

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets...

6.5AI score0.02047EPSS
SaveExploits0References1
Rows per page
Query Builder