Multiple Siemens SIMATIC Products Authentication Bypass Vulnerabilities
Multiple Siemens SIMATIC products are affected by vulnerabilities that allow attackers to bypass authentication. SPDX-FileCopyrightText: 2011 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders...
Siemens SIMATIC WinCC flexible multiple security vulnerabilities
HmiLoad and miniweb multiple security vulnerabilities...
Vulnerabilities in Siemens SIMATIC WinCC flexible 2008 SP2
Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms: Windows Bugs: A HmiLoad strings sta...
Siemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities
Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms: Windows Bugs: A HmiLoad strings sta...
Siemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities
Siemens SIMATIC WinCC Flexible Runtime - Multiple Vulnerabilities Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2...
Was The Three Character Password Used To Hack South Houston's Water Treatment Plant A Siemens Default?
Siemens said on Tuesday that it is working with the U.S. Department of Homeland Security to investigate a cyber intrusion into a water treatment plant in South Houston, Texas, but couldn’t confirm that a default, three digit password hard coded into an application used to control the company’s...
Hacker Says Texas Town Used Three Character Password To Secure Internet Facing SCADA System
In an e-mail interview with Threatpost, the hacker who compromised software used to manage water infrastructure for South Houston, Texas, said the district had HMI human machine interface software used to manage water and sewage infrastructure accessible to the Internet and used a password that w...
Siemens Simatic HMI Authentication Vulnerabilities
Overview ICS-CERT is aware of a public report by independent security researchers Billy Rios and Terry McCorkle concerning authentication bypass vulnerabilities affecting Siemens SIMATIC HMI products which are supervisory control and data acquisition/human-machine interface SCADA/HMI products...
Siemens SIMATIC S7-1200 CPU V1/V2 Devices
SUMMARY SIMATIC S7-1200 CPU V1/V2 controllers contain two vulnerabilities that could allow an unauthenticated remote attacker - to trigger functions by record and playback of legitimate network communication, or - to place the controller in stop/defect state by causing a communications error...
Metasploit Holding On Siemens Exploits
UPDATE: A week after a security researcher decided to cancel a technical discussion of security holes in industrial control software from Siemens, Inc., public exploits for the vulnerabilities are on hold while the company works to shore up systems running its Simatic programmable logic controlle...
SCADA Holes Allowed Remote Takedown of Siemens Systems
Security researcher Dillon Beresford decided not to present a talk at the TakedownCon in Dallas on Thursday, citing concerns about mayhem that could have resulted. But in an e-mail, he told Threatpost that the vulnerabilities could allow remote attackers to start or stop Siemens Programmable Logi...
CVE-2010-2772
CVE-2010-2772 affects Siemens SIMATIC WinCC and SIMATIC PCS 7: a security bypass via default hard-coded SQL credentials allows remote attackers to access the backend database with administrative-like access. The vulnerability is tied to use of default credentials in the WinCC SQL server, permitti...
CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. Recent assessments: Assessed Attacker...