4194 matches found
Design/Logic Flaw
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433...
CVE-2014-4684
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433...
CVE-2014-4686
Siemens SIMATIC WinCC (before 7.3) contains a hard-coded encryption key in the Project administration component, enabling remote attackers to extract the key from another installation and use it to sniff traffic on TCP port 1030. This can lead to credential exposure and elevated privileges. Publi...
CVE-2014-4684
The CVE-2014-4684 issue affects Siemens SIMATIC WinCC before 7.3 (as used in PCS7 and other products) where the WinCC database server could allow remote authenticated users to escalate privileges by sending a crafted command to TCP/1433. Connected sources confirm root cause in the database server...
CVE-2014-4683
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a 1 HTTP or 2 HTTPS request...
CVE-2014-4682
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request...
CVE-2014-4686
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during...
CVE-2014-4683
The CVE-2014-4683 issue affects Siemens SIMATIC WinCC WebNavigator: remote authenticated users can escalate privileges via HTTP/HTTPS requests to the WebNavigator server (ports 80/443). Sources describe Prague: Privilege gain through WebNavigator’s access control, with explicit remediation in upd...
CVE-2014-4685
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control...
CVE-2014-4685
CVE-2014-4685 affects Siemens SIMATIC WinCC prior to 7.3 (used in PCS7). Root cause: weak system-object access control enabling local privilege escalation for local users. Siemens released fixes in WinCC 7.3 (and PCS7 8.1); upgrading is advised. Other sources note mitigation steps and a broader s...
CVE-2014-4682
CVE-2014-4682 pertains to the WebNavigator server in Siemens SIMATIC WinCC (pre-7.3). Multiple sources describe that the WebNavigator at ports 80/443 could allow unauthenticated remote access to sensitive data via specially crafted HTTP requests, with a CVSSv2 base score of 5.0. The broader Sieme...
Siemens Simatic S7-1200 CPU START/STOP Module
No description provided by source...
Siemens Simatic S7-300 PLC Remote Memory Viewer
No description provided by source. Exploit Title: Siemens Simatic S7 300 Remote Memory Viewer Backdoor Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3 Msf::Auxiliary...
Siemens SIMATIC WinCC Flexible (Runtime) Multiple Vulnerabilities
No description provided by source. Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms:...
Siemens Simatic S7-300/400 CPU START/STOP Module
No description provided by source...
Siemens Update on Heartbleed Patches in ICS, SCADA
Industrial control equipment manufacturer Siemens has produced a security update that mitigates the OpenSSL Heartbleed vulnerability in its eLAN systems and now its WinCC OA supervisory control and data acquisition SCADA software as well. The company is continuing to work on patches to resolve th...
Siemens SIMATIC WinCC Vulnerabilities (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-14-205-02 Siemens SIMATIC WinCC Vulnerabilities that was published July 24, 2014, on the NCCIC/ICS-CERT web site. Researchers Sergey Gordeychik, Alexander Tlyapov, Dmitry Nagibin, and Gleb Gritsai of Positive...
CVE-2014-2909
CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors...
CVE-2014-2908
Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...
Crlf injection
CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors...