Lucene search
+L

4194 matches found

Prion
Prion
added 2014/07/24 2:55 p.m.22 views

Design/Logic Flaw

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433...

6CVSS6.9AI score0.01344EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2014/07/24 2:0 p.m.39 views

CVE-2014-4684

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433...

6.4AI score0.01344EPSS
SaveExploits0References1
CVE
CVE
added 2014/07/24 2:0 p.m.70 views

CVE-2014-4686

Siemens SIMATIC WinCC (before 7.3) contains a hard-coded encryption key in the Project administration component, enabling remote attackers to extract the key from another installation and use it to sniff traffic on TCP port 1030. This can lead to credential exposure and elevated privileges. Publi...

6.8CVSS6.1AI score0.01087EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2014/07/24 2:0 p.m.92 views

CVE-2014-4684

The CVE-2014-4684 issue affects Siemens SIMATIC WinCC before 7.3 (as used in PCS7 and other products) where the WinCC database server could allow remote authenticated users to escalate privileges by sending a crafted command to TCP/1433. Connected sources confirm root cause in the database server...

6CVSS6.6AI score0.01344EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2014/07/24 2:0 p.m.41 views

CVE-2014-4683

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a 1 HTTP or 2 HTTPS request...

6.4AI score0.01222EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2014/07/24 2:0 p.m.47 views

CVE-2014-4682

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request...

6.1AI score0.01686EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2014/07/24 2:0 p.m.42 views

CVE-2014-4686

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during...

6AI score0.01087EPSS
SaveExploits0References1
CVE
CVE
added 2014/07/24 2:0 p.m.61 views

CVE-2014-4683

The CVE-2014-4683 issue affects Siemens SIMATIC WinCC WebNavigator: remote authenticated users can escalate privileges via HTTP/HTTPS requests to the WebNavigator server (ports 80/443). Sources describe Prague: Privilege gain through WebNavigator’s access control, with explicit remediation in upd...

4.9CVSS6.6AI score0.01222EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2014/07/24 2:0 p.m.44 views

CVE-2014-4685

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control...

6.4AI score0.00365EPSS
SaveExploits0References1
CVE
CVE
added 2014/07/24 2:0 p.m.73 views

CVE-2014-4685

CVE-2014-4685 affects Siemens SIMATIC WinCC prior to 7.3 (used in PCS7). Root cause: weak system-object access control enabling local privilege escalation for local users. Siemens released fixes in WinCC 7.3 (and PCS7 8.1); upgrading is advised. Other sources note mitigation steps and a broader s...

4.6CVSS6.6AI score0.00365EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2014/07/24 2:0 p.m.72 views

CVE-2014-4682

CVE-2014-4682 pertains to the WebNavigator server in Siemens SIMATIC WinCC (pre-7.3). Multiple sources describe that the WebNavigator at ports 80/443 could allow unauthenticated remote access to sensitive data via specially crafted HTTP requests, with a CVSSv2 base score of 5.0. The broader Sieme...

5CVSS6.2AI score0.01686EPSS
SaveExploits0References1Affected Software2
seebug.org
seebug.org
added 2014/07/01 12:0 a.m.33 views

Siemens Simatic S7-1200 CPU START/STOP Module

No description provided by source...

7.1AI score
SaveExploits0
seebug.org
seebug.org
added 2014/07/01 12:0 a.m.72 views

Siemens Simatic S7-300 PLC Remote Memory Viewer

No description provided by source. Exploit Title: Siemens Simatic S7 300 Remote Memory Viewer Backdoor Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class Metasploit3 Msf::Auxiliary...

7.1AI score
SaveExploits0
seebug.org
seebug.org
added 2014/07/01 12:0 a.m.73 views

Siemens SIMATIC WinCC Flexible (Runtime) Multiple Vulnerabilities

No description provided by source. Luigi Auriemma Application: Siemens SIMATIC WinCC flexible Runtime http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/Pages/Default.aspx Versions: 2008 SP2 + security patch 1 Platforms:...

7.1AI score
SaveExploits0
seebug.org
seebug.org
added 2014/07/01 12:0 a.m.20 views

Siemens Simatic S7-300/400 CPU START/STOP Module

No description provided by source...

7.1AI score
SaveExploits0
ThreatPost
ThreatPost
added 2014/04/28 12:3 p.m.11 views

Siemens Update on Heartbleed Patches in ICS, SCADA

Industrial control equipment manufacturer Siemens has produced a security update that mitigates the OpenSSL Heartbleed vulnerability in its eLAN systems and now its WinCC OA supervisory control and data acquisition SCADA software as well. The company is continuing to work on patches to resolve th...

SaveExploits0References9
ICS
ICS
added 2014/04/26 6:0 a.m.88 views

Siemens SIMATIC WinCC Vulnerabilities (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-14-205-02 Siemens SIMATIC WinCC Vulnerabilities that was published July 24, 2014, on the NCCIC/ICS-CERT web site. Researchers Sergey Gordeychik, Alexander Tlyapov, Dmitry Nagibin, and Gleb Gritsai of Positive...

6CVSS6.8AI score0.01686EPSS
SaveExploits0References10
NVD
NVD
added 2014/04/25 5:12 a.m.29 views

CVE-2014-2909

CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors...

5.8CVSS6.9AI score0.02417EPSS
SaveExploits1References3
NVD
NVD
added 2014/04/25 5:12 a.m.23 views

CVE-2014-2908

Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...

4.3CVSS5.6AI score0.20862EPSS
SaveExploits3References4
Prion
Prion
added 2014/04/25 5:12 a.m.27 views

Crlf injection

CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors...

5.8CVSS7.4AI score0.02417EPSS
SaveExploits1References3Affected Software1
Rows per page
Query Builder