Lucene search
+L

4194 matches found

NVD
NVD
added 2019/10/10 2:15 p.m.36 views

CVE-2019-13929

A vulnerability has been identified in SIMATIC IT UADM All versions V1.3. An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security...

6.5CVSS6.3AI score0.01273EPSS
SaveExploits0References1
NVD
NVD
added 2019/10/10 2:15 p.m.36 views

CVE-2019-13921

A vulnerability has been identified in SIMATIC WinAC RTX F 2010 All versions SP3 Update 1. Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is...

7.5CVSS7.4AI score0.01367EPSS
SaveExploits0References1
Prion
Prion
added 2019/10/10 2:15 p.m.23 views

Race condition

A vulnerability has been identified in SIMATIC WinAC RTX F 2010 All versions SP3 Update 1. Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is...

5CVSS7.4AI score0.01367EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2019/10/10 2:15 p.m.15 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC IT UADM All versions V1.3. An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security...

4CVSS6.3AI score0.01273EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2019/10/10 2:15 p.m.31 views

Race condition

A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFIN...

5CVSS7.5AI score0.02065EPSS
SaveExploits0References1Affected Software44
Cvelist
Cvelist
added 2019/10/10 1:49 p.m.44 views

CVE-2019-13929

A vulnerability has been identified in SIMATIC IT UADM All versions V1.3. An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security...

6.3AI score0.01273EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2019/10/10 1:49 p.m.44 views

CVE-2019-13921

A vulnerability has been identified in SIMATIC WinAC RTX F 2010 All versions SP3 Update 1. Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large HTTP request is...

7.4AI score0.01367EPSS
SaveExploits0References1
CVE
CVE
added 2019/10/10 1:49 p.m.120 views

CVE-2019-10923

CVE-2019-10923 affects Siemens Industrial Real-Time devices (e.g., CP1604/CP1616, PROFINET IO DK/EK-ERTEC kits, SCALANCE X‑200IRT, ET200 family, SIMATIC S7-300/400 CPUs, ET200S/ET200M, etc.). A remote attacker with network access can cause a denial of service by breaking the real‑time synchroniza...

7.5CVSS7.3AI score0.01401EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2019/10/10 1:49 p.m.65 views

CVE-2019-13929

CVE-2019-13929 affects Siemens SIMATIC IT UADM (pre-1.3). A authenticated remote attacker with network access to port 1434/tcp could recover a password enabling read/write access to the related TeamCenter station, without user interaction. The root cause is use of a hard-coded cryptographic key. ...

6.5CVSS6.3AI score0.01273EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2019/10/10 1:49 p.m.61 views

CVE-2019-13921

CVE-2019-13921 affects Siemens SIMATIC WinAC RTX (F) 2010 (all versions prior to SP3 Update 1). The vulnerability allows an unauthenticated attacker with network access to trigger a denial-of-service condition by sending a large HTTP request to the host running WinAC RTX (F) 2010, potentially imp...

7.5CVSS7.3AI score0.01367EPSS
SaveExploits0References1Affected Software1
ICS
ICS
added 2019/10/10 12:0 p.m.74 views

Siemens Industrial Products Local Privilege Escalation Vulnerability (Update I)

1. EXECUTIVE SUMMARY CVSS v3 6.4 ATTENTION: Exploitable locally Vendor: Siemens Equipment: Industrial Products Vulnerability: Improper privilege management 2. UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-16-313-02 Siemens Industrial Products Local...

6.9CVSS7AI score0.00378EPSS
SaveExploits0References55
CVE
CVE
added 2019/10/10 12:0 a.m.148 views

CVE-2019-10936

Siemens PROFINET devices (e.g., SIMATIC ET200S/ET200SP and related ecosystem listed in the advisory plugins) are affected by CVE-2019-10936. The root cause is handling large amounts of specially crafted UDP packets, enabling an unauthenticated remote attacker to trigger a denial-of-service condit...

7.5CVSS7.5AI score0.02065EPSS
SaveExploits0References2Affected Software1
ICS
ICS
added 2019/10/08 12:0 a.m.114 views

Siemens SIMATIC WinAC RTX (F) 2010 (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC WinAC RTX F 2010 --------- Begin Update A Part 1 of 4 --------- Vulnerability: Insufficient Resource Pool --------- End Update A Part 1 of 4 --------- 2. UPDATE...

7.5CVSS7.8AI score0.01367EPSS
SaveExploits0References9
Symantec
Symantec
added 2019/10/08 12:0 a.m.35 views

Siemens SIMATIC WinAC RTX (F) 2010 CVE-2019-13921 Denial of Service Vulnerability

Description Siemens SIMATIC WinAC RTX F 2010 is prone to denial of service vulnerability Remote attackers may exploit this issue to cause denial-of-service conditions. Technologies Affected Siemens SIMATIC WinAC RTX F 2010 Recommendations Run all software as a nonprivileged user with minimal acce...

0.6AI score0.01367EPSS
SaveExploits0References1
ICS
ICS
added 2019/10/08 12:0 a.m.80 views

ICSA-19-281-04 Siemens SIMATIC IT UADM

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC IT Unified Architecture Discrete Manufacturing UADM Vulnerability: Use of Hard-coded Cryptographic Key 2. RISK EVALUATION Successful exploitation of this vulnerability...

6.5CVSS6.9AI score0.01273EPSS
SaveExploits0References9
ICS
ICS
added 2019/10/08 12:0 a.m.200 views

Siemens Industrial Real-Time (IRT) Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

7.5CVSS7.7AI score0.01401EPSS
SaveExploits0References10
Symantec
Symantec
added 2019/10/08 12:0 a.m.37 views

Siemens SIMATIC IT UADM CVE-2019-13929 Hardcoded Cryptographic Key Vulnerability

Description Siemens SIMATIC IT UADM is prone to a hard-coded cryptographic key vulnerability. An attacker can exploit this issue to gain unauthorized access to the vulnerable device and perform unauthorized actions. Versions prior to SIMATIC IT UADM 1.3 are vulnerable. Technologies Affected Sieme...

1.2AI score0.01273EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2019/10/03 12:0 a.m.7 views

Certification Bypass Vulnerability in SIEMENS SIMATIC S7-200 Smart PLCs

Siemens is a leading global technology company providing solutions for customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drives and software through innovations in electrification, automation and digitalization. An authentication...

7AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/10/02 12:0 a.m.24 views

Siemens SIMATIC RF6XXR < 3.2.1 Multiple Vulnerabilities (ICSA-19-192-04)

Binary data 720302.prm...

4.3CVSS5.7AI score0.73327EPSS
SaveExploits4References2
CNVD
CNVD
added 2019/09/23 12:0 a.m.9 views

SIEMENS S7-200 SIMATIC PLC suffers from a remote control vulnerability (CNVD-2019-37705)

S7-200 SMART is a small PLC developed by Siemens with a friendly interface and more user-friendly software operation. A remote control vulnerability exists in SIEMENS S7-200 SIMATIC PLC. An attacker can exploit the vulnerability to construct special application layer data messages that result in ...

6.9AI score
SaveExploits0
Rows per page
Query Builder