Lucene search
+L

4194 matches found

Prion
Prion
added 2022/04/12 9:15 a.m.27 views

Improper access control

A vulnerability has been identified in SIMATIC STEP 7 TIA Portal V15 All versions, SIMATIC STEP 7 TIA Portal V16 All versions V16 Update 5, SIMATIC STEP 7 TIA Portal V17 All versions V17 Update 2. An attacker could achieve privilege escalation on the web server of certain devices due to improper...

7.2CVSS7.7AI score0.00236EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2022/04/12 9:15 a.m.22 views

Deserialization of untrusted data

A vulnerability has been identified in SIMATIC Energy Manager Basic All versions V7.3 Update 1, SIMATIC Energy Manager PRO All versions V7.3 Update 1. The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the...

10CVSS9.6AI score0.35749EPSS
SaveExploits0References1Affected Software2
Prion
Prion
added 2022/04/12 9:15 a.m.21 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC PCS neo Administration Console All versions V3.1 SP1, SINETPLAN All versions, TIA Portal V15, V15.1, V16 and V17. The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this...

7.8CVSS7.3AI score0.01409EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2022/04/12 9:07 a.m.34 views

CVE-2022-27194

A vulnerability has been identified in SIMATIC PCS neo Administration Console All versions V3.1 SP1, SINETPLAN All versions, TIA Portal V15, V15.1, V16 and V17. The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this...

7.5AI score0.01409EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:07 a.m.107 views

CVE-2022-27194

CVE-2022-27194 affects Siemens SIMATIC PCS neo (Administration Console), SINETPLAN, and TIA Portal (V15–V17). The issue arises from improper handling of specially crafted packets sent to port 8888/TCP, leading to a remote Denial-of-Service that requires manual device restart. Mitigations document...

7.8CVSS7.3AI score0.01409EPSS
SaveExploits0References1Affected Software3
CVE
CVE
added 2022/04/12 9:07 a.m.94 views

CVE-2022-23450

Siemens SIMATIC Energy Manager (Basic and PRO) prior to v7.3 Update 1 is affected by an insecure deserialization vulnerability. An unauthenticated remote attacker can send a maliciously crafted serialized object to the vulnerable service, potentially executing arbitrary code with SYSTEM privilege...

10CVSS9.5AI score0.35749EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2022/04/12 9:07 a.m.33 views

CVE-2022-23450

A vulnerability has been identified in SIMATIC Energy Manager Basic All versions V7.3 Update 1, SIMATIC Energy Manager PRO All versions V7.3 Update 1. The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the...

9.7AI score0.35749EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/04/12 9:07 a.m.36 views

CVE-2022-23449

A vulnerability has been identified in SIMATIC Energy Manager Basic All versions V7.3 Update 1, SIMATIC Energy Manager PRO All versions V7.3 Update 1. A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the...

7.3AI score0.00315EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:07 a.m.89 views

CVE-2022-23449

Siemens SIMATIC Energy Manager Basic (all versions < 7.3 Update 1) and PRO (all versions

7.3CVSS7.1AI score0.00315EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2022/04/12 9:07 a.m.33 views

CVE-2022-23448

A vulnerability has been identified in SIMATIC Energy Manager Basic All versions V7.3 Update 1, SIMATIC Energy Manager PRO All versions V7.3 Update 1. Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local...

7.8AI score0.0024EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:07 a.m.91 views

CVE-2022-23448

CVE-2022-23448 affects Siemens SIMATIC Energy Manager Basic (all versions < v7.3 Update 1) and SIMATIC Energy Manager PRO (all versions

7.8CVSS7.6AI score0.0024EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2022/04/12 9:07 a.m.93 views

CVE-2021-42029

CVE-2021-42029 affects SIMATIC STEP 7 (TIA Portal) V15 (all versions), V16 (all versions before V16 Update 5), and V17 (all versions before V17 Update 2). Root cause: improper access control in the engineering system software that can allow privilege escalation on the web server of affected devic...

7.8CVSS7.6AI score0.00236EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/04/12 9:07 a.m.22 views

CVE-2021-42029

A vulnerability has been identified in SIMATIC STEP 7 TIA Portal V15 All versions, SIMATIC STEP 7 TIA Portal V16 All versions V16 Update 5, SIMATIC STEP 7 TIA Portal V17 All versions V17 Update 2. An attacker could achieve privilege escalation on the web server of certain devices due to improper...

7.9AI score0.00236EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2022/04/12 9:07 a.m.7 views

CVE-2021-40368

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 All versions, SIMATIC S7-400 CPU 412-2 DP V7 All versions, SIMATIC S7-400 CPU 412-2 PN/DP V7 All versions V7.0.3, SIMATIC S7-400 CPU 414-2 DP V7 All versions, SIMATIC S7-400 CPU 414-3 DP V7 All versions, SIMATIC S7-400 CPU 414-...

7.5CVSS7.3AI score0.00988EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/04/12 9:07 a.m.40 views

CVE-2021-40368

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 All versions, SIMATIC S7-400 CPU 412-2 DP V7 All versions, SIMATIC S7-400 CPU 412-2 PN/DP V7 All versions V7.0.3, SIMATIC S7-400 CPU 414-2 DP V7 All versions, SIMATIC S7-400 CPU 414-3 DP V7 All versions, SIMATIC S7-400 CPU 414-...

7.5CVSS7.5AI score0.00988EPSS
SaveExploits0References1
CVE
CVE
added 2022/04/12 9:07 a.m.88 views

CVE-2021-40368

CVE-2021-40368 affects Siemens SIMATIC S7-400 family CPUs (e.g., HV6, PN/DP V7, S7-410 V8/V10, SIPLUS variants) where specially crafted packets sent to port 102/tcp can cause a Denial-of-Service, requiring a restart. Root cause: improper handling of crafted network packets leading to unavailable ...

7.5CVSS7.3AI score0.00988EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/04/12 12:00 a.m.11 views

Siemens SIMATIC S7-400 缓冲区错误漏洞

The SIMATIC S7-400 CPU family is designed for process control in industrial environments. A denial of service vulnerability exists in the Siemens SIMATIC S7-400 CPUs that can be exploited by an attacker to create a denial of service condition...

7.5CVSS5.6AI score0.00988EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2022/04/12 12:00 a.m.9 views

Siemens SIMATIC 安全漏洞

SIMATIC STEP 7 TIA Portal is the engineering software for configuring and programming SIMATIC controllers. An access control error vulnerability exists in Siemens TIA Portal, which can be exploited by an attacker to achieve elevation of privilege...

7.8CVSS5.6AI score0.00236EPSS
SaveExploits0References5
CVE
CVE
added 2022/04/12 12:00 a.m.158 views

CVE-2022-25622

CVE-2022-25622 affects Siemens PROFINET PNIO stack integrated with Interniche stack. The root cause is improper handling of internal resources for TCP segments when the minimum TCP header length is below the defined value, enabling an attacker to cause a DoS on TCP services by sending crafted TCP...

7.5CVSS6.2AI score0.0087EPSS
SaveExploits0References2Affected Software1
CNNVD
CNNVD
added 2022/04/12 12:00 a.m.9 views

多款Siemens SIMATIC 产品 资源管理错误漏洞

SIMATIC PCS neo is a distributed control system DCS.TIA Administrator is a web-based framework.Siemens Network Planner SINETPLAN supports you as a planner of PROFINET-based automation systems.TIA Portal is a PC A denial of service vulnerability exists in Siemens TIA Administrator, which can be...

7.8CVSS5.6AI score0.01409EPSS
SaveExploits0References5
Rows per page
Query Builder