•added 2014/03/22 12:00 a.m.•7 views

CVE-2014-2258: Undefined Security Weakness

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...

7.8CVSS5.8AI score0.04731EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/03/22 12:00 a.m.•8 views

CVE-2014-2250: Undefined Security Weakness

The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...

8.3CVSS5.9AI score0.03144EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/03/22 12:00 a.m.•11 views

CVE-2014-2254: Undefined Security Weakness

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...

7.8CVSS5.8AI score0.04731EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2014/03/22 12:00 a.m.•6 views

PT-2014-1954

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows remote attackers to cause a denial of service, resulting in the device transitioning to defect mode, followed by a cold restart. This is achieved b...

7.8CVSS0.04731EPSS
SaveExploits1References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/03/22 12:00 a.m.•9 views

CVE-2014-2252: Undefined Security Weakness

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...

6.1CVSS5.8AI score0.01242EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2014/03/20 12:00 a.m.•3 views

PT-2014-1004

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows remote attackers to cause a denial of service, resulting in the device transitioning to defect mode, which lasts until a hardware reset is performe...

6.1CVSS0.01242EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2014/03/20 12:00 a.m.•5 views

PT-2014-1003

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue concerns a problem with the random-number generator in the authentication handler of the web server, which lacks sufficient entropy. This makes it easier...

8.3CVSS0.03144EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2014/03/20 12:00 a.m.•6 views

PT-2014-1178

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows a remote attacker to cause a denial of service, resulting in the device entering defect mode, by sending crafted HTTP packets to the TCP port 80...

7.8CVSS0.04731EPSS
SaveExploits1References7
Positive Technologies
Positive Technologies
•added 2014/03/20 12:00 a.m.•9 views

PT-2014-1002

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition, via crafted ISO-TSAP packets. Exploitation can be achieved by...

7.8CVSS0.03678EPSS
SaveExploits1References6
Positive Technologies
Positive Technologies
•added 2014/03/16 12:00 a.m.•6 views

PT-2014-1955

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1500 CPU PLC devices versions prior to 1.5.0 Siemens SIMATIC S7-1200 CPU PLC devices versions prior to 4.0 Description A cross-site request forgery CSRF issue affects the software, allowing remote attackers to hijack the...

5.8CVSS0.01344EPSS
SaveExploits1References9
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/03/16 12:00 a.m.•7 views

CVE-2014-2249: Cross-Site Request Forgery (CSRF)

Cross-site request forgery CSRF vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors...

5.8CVSS5.9AI score0.01344EPSS