23 matches found
CVE-2023-48364
A vulnerability has been identified in OpenPCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC BATCH V9.1 All versions V9.1 SP2 UC05, SIMATIC PCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC Route Control V9.1 All versions V9.1 SP2 UC05, SIMATIC WinCC Runtime Professional V18 All versions V18 Update 4,...
CVE-2023-48363
A vulnerability has been identified in OpenPCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC BATCH V9.1 All versions V9.1 SP2 UC05, SIMATIC PCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC Route Control V9.1 All versions V9.1 SP2 UC05, SIMATIC WinCC Runtime Professional V18 All versions V18 Update 4,...
Design/Logic Flaw
A vulnerability has been identified in OpenPCS 7 V9.1 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC Route Control V9.1 All versions, SIMATIC WinCC Runtime Professional V18 All versions, SIMATIC WinCC Runtime Professional V19 All versions, SIMATIC WinCC V7...
Design/Logic Flaw
A vulnerability has been identified in OpenPCS 7 V9.1 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC Route Control V9.1 All versions, SIMATIC WinCC Runtime Professional V18 All versions, SIMATIC WinCC Runtime Professional V19 All versions, SIMATIC WinCC V7...
CVE-2023-48364
A vulnerability has been identified in OpenPCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC BATCH V9.1 All versions V9.1 SP2 UC05, SIMATIC PCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC Route Control V9.1 All versions V9.1 SP2 UC05, SIMATIC WinCC Runtime Professional V18 All versions V18 Update 4,...
CVE-2023-48363
CVE-2023-48363 affects Siemens OpenPCS 7, SIMATIC BATCH/PCS 7, Route Control, WinCC Runtime Professional V18/V19, WinCC V7.4/V7.5/V8.0. Root cause: improper handling of certain unorganized RPC messages in the RPC server, leading to a denial-of-service. Affected versions include OpenPCS 7 V9.1 and...
CVE-2023-48364: NULL Pointer Dereference
A vulnerability has been identified in OpenPCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC BATCH V9.1 All versions V9.1 SP2 UC05, SIMATIC PCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC Route Control V9.1 All versions V9.1 SP2 UC05, SIMATIC WinCC Runtime Professional V18 All versions V18 Update 4,...
CVE-2023-48363: NULL Pointer Dereference
A vulnerability has been identified in OpenPCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC BATCH V9.1 All versions V9.1 SP2 UC05, SIMATIC PCS 7 V9.1 All versions V9.1 SP2 UC05, SIMATIC Route Control V9.1 All versions V9.1 SP2 UC05, SIMATIC WinCC Runtime Professional V18 All versions V18 Update 4,...
PT-2024-2755 · Siemens · Simatic Route Control +5
Name of the Vulnerable Software and Affected Versions: OpenPCS 7 versions prior to V9.1 SP2 UC05 SIMATIC BATCH versions prior to V9.1 SP2 UC05 SIMATIC PCS 7 versions prior to V9.1 SP2 UC05 SIMATIC Route Control versions prior to V9.1 SP2 UC05 SIMATIC WinCC Runtime Professional version V18 through...
PT-2024-2743 · Siemens · Simatic Route Control +5
Name of the Vulnerable Software and Affected Versions: OpenPCS 7 versions prior to V9.1 SP2 UC05 SIMATIC BATCH versions prior to V9.1 SP2 UC05 SIMATIC PCS 7 versions prior to V9.1 SP2 UC05 SIMATIC Route Control versions prior to V9.1 SP2 UC05 SIMATIC WinCC Runtime Professional V18 versions prior ...
CVE-2021-40359
A vulnerability has been identified in OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd4, OpenPCS 7 V9.1 All versions, SIMATIC BATCH V8.2 All versions, SIMATIC BATCH V9.0 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC NET PC Software V14 All versions, SIMATIC NET PC...
CVE-2021-40359
A vulnerability has been identified in OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd4, OpenPCS 7 V9.1 All versions, SIMATIC BATCH V8.2 All versions, SIMATIC BATCH V9.0 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC NET PC Software V14 All versions, SIMATIC NET PC...
Authentication flaw
A vulnerability has been identified in OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd4, OpenPCS 7 V9.1 All versions, SIMATIC BATCH V8.2 All versions, SIMATIC BATCH V9.0 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC NET PC Software V14 All versions, SIMATIC NET PC...
CVE-2021-40359
CVE-2021-40359 is a path traversal vulnerability in Siemens products (OpenPCS 7, SIMATIC BATCH, SIMATIC NET PC Software, SIMATIC PCS 7, SIMATIC Route Control, SIMATIC WinCC, etc.). The issue arises from improper neutralization of special elements in pathnames when downloading files, allowing an a...
CVE-2021-40359: Improper Limitation of a Pathname to a Restricted Directory
A vulnerability has been identified in OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd4, OpenPCS 7 V9.1 All versions, SIMATIC BATCH V8.2 All versions, SIMATIC BATCH V9.0 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC NET PC Software V14 All versions, SIMATIC NET PC...
PT-2021-22877 · Siemens · Openpcs 7 +5
Name of the Vulnerable Software and Affected Versions: OpenPCS 7 versions 7.0 through 9.1 SIMATIC BATCH versions 8.2 through 9.1 SIMATIC NET PC Software versions 14 through 17 SIMATIC PCS 7 versions 8.2 through 9.1 SIMATIC Route Control versions 8.2 through 9.1 SIMATIC WinCC versions 7.4 through ...
CVE-2019-19282
A vulnerability has been identified in OpenPCS 7 V8.1 All versions, OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd3, SIMATIC BATCH V8.1 All versions, SIMATIC BATCH V8.2 All versions V8.2 Upd12, SIMATIC BATCH V9.0 All versions V9.0 SP1 Upd5, SIMATIC NET PC Software V14 All...
CVE-2019-19282
A vulnerability has been identified in OpenPCS 7 V8.1 All versions, OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd3, SIMATIC BATCH V8.1 All versions, SIMATIC BATCH V8.2 All versions V8.2 Upd12, SIMATIC BATCH V9.0 All versions V9.0 SP1 Upd5, SIMATIC NET PC Software V14 All...
CVE-2019-19282
CVE-2019-19282 describes an incorrect calculation of buffer size (CWE-131) that allows a remote attacker to cause a denial-of-service on Siemens industrial software when encrypted communication is enabled. Exploitation requires network access and no privileges/UI. Affected products span OpenPCS 7...
CVE-2019-19282: Incorrect Calculation of Buffer Size
A vulnerability has been identified in OpenPCS 7 V8.1 All versions, OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd3, SIMATIC BATCH V8.1 All versions, SIMATIC BATCH V8.2 All versions V8.2 Upd12, SIMATIC BATCH V9.0 All versions V9.0 SP1 Upd5, SIMATIC NET PC Software V14 All...