28 matches found
CVE-2017-12069: Improper Restriction of XML External Entity Reference
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server LDS before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 All versions V8.1 and earlier, SIMATIC WinCC All versions V7.4 SP1, SIMATIC WinCC Runtime...
CVE-2017-6865: Improper Input Validation
A vulnerability has been identified in Primary Setup Tool PST All versions V4.2 HF1, SIMATIC Automation Tool All versions V3.0, SIMATIC NET PC-Software All versions V14 SP1, SIMATIC PCS 7 V8.1 All versions, SIMATIC PCS 7 V8.2 All versions V8.2 SP1, SIMATIC STEP 7 TIA Portal V13 All versions V13...
PT-2017-3766
Name of the Vulnerable Software and Affected Versions: SIMATIC Automation Tool versions prior to V3.0 SIMATIC NET PC-Software versions prior to V14 SP1 SIMATIC PCS 7 V8.1 all versions SIMATIC PCS 7 V8.2 versions prior to V8.2 SP1 SIMATIC STEP 7 TIA Portal V13 versions prior to V13 SP2 SIMATIC STE...
CVE-2016-7165: Improper Access Control
A vulnerability has been identified in Primary Setup Tool PST All versions V4.2 HF1, SIMATIC IT Production Suite All versions V7.0 SP1 HFX 2, SIMATIC NET PC-Software All versions V14, SIMATIC PCS 7 V7.1 All versions, SIMATIC PCS 7 V8.0 All versions, SIMATIC PCS 7 V8.1 All versions, SIMATIC PCS 7...
Siemens Discloses Local Privilege Escalation Bug in SCADA Gear
German engineering giant Siemens is warning operators of a local privilege escalation vulnerability that leaves more than a dozen models of its SCADA equipment open to attack. Some of the issues have been patched, or in other cases, Siemens has provided a workaround. The vulnerability was disclos...
CVE-2016-5874: Improper Input Validation
Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service OPC UA service outage via crafted TCP packets...
PT-2016-6718
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC NET PC-Software versions prior to 13 SP2 Description The issue allows remote attackers to cause a denial of service, specifically an OPC UA service outage, by sending crafted TCP packets. Recommendations For versions prior to 1...
Siemens SIMATIC NET PC-Software Denial-of-Service Vulnerability
OVERVIEW Siemens has identified a denial-of-service vulnerability in SIMATIC NET PC-Software. Vladimir Dashchenko and Sergey Temnikov from Kaspersky Labs reported this issue directly to Siemens. Siemens has produced a new version to mitigate this vulnerability. This vulnerability could be exploit...