323 matches found
CVE-2024-39798
Multiple external config control vulnerabilities exists in the openvpn.cgi openvpnserversetup functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these...
WAVLINK AC3000 安全漏洞
WAVLINK AC3000 is a wireless router from China Ruiyin WAVLINK. The WAVLINK AC3000 suffers from a buffer overflow vulnerability, which is caused by the selmode parameter of the qos.cgi qossettings function failing to properly validate the length of the input data, which can be exploited by an...
PT-2025-2580 · Wavlink · Wavlink Ac3000
Name of the Vulnerable Software and Affected Versions: Wavlink AC3000 version M33A8.V5030.210505 Description: Multiple buffer overflow vulnerabilities exist in the qos.cgi qos settings functionality. A specially crafted HTTP request can lead to stack-based buffer overflow. An attacker can make an...
CVE-2024-2103
Inclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably: SEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5...
CVE-2024-2103
CVE-2024-2103 covers an “inclusion of undocumented features” vulnerability affecting SEL relays: SEL-700BT, SEL-700G, SEL-710-5, SEL-751, SEL-787-2/ -3/ -4, and SEL-787Z. The issue arises when an attacker with privileged access can trigger undocumented features, causing the relay to behave unpred...
Schweitzer Engineering Laboratories SEL 700 series relays
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.9 ATTENTION : Exploitable remotely/low attack complexity Vendor : Schweitzer Engineering Laboratories Equipment : SEL 700 series relays Vulnerability : Inclusion of Undocumented Features 2. RISK EVALUATION Successful exploitation of this vulnerability...
The vulnerability of the microprogrammed protection system for the SEL-451 phase-change order relay exists due to an unreliable authentication mechanism. This allows attackers to execute session hijacking attacks and bypass the authentication process.
The vulnerability of the SEL-451 phase-changing protection relay’s microprogramming software exists due to an unreliable authentication mechanism. Exploiting this vulnerability allows a malicious actor to perform session hijacking attacks and bypass the authentication process...
Schweitzer Engineering Laboratories SEL-411L Input Validation Error Vulnerability
The Schweitzer Engineering Laboratories SEL-411L is a state-of-the-art line differential protection, automation and control system from Schweitzer Engineering Laboratories, USA. An input validation error vulnerability exists in the Schweitzer Engineering Laboratories SEL-411L, which can be...
CVE-2023-34388
An Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details...
CVE-2023-34390
An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services. See product Instruction Manual Appendix A dated 20230830 for more details...
CVE-2023-34389
An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time. See product Instruction Manual Appendix A dated 20230830 for more...
CVE-2023-2267
An Improper Input Validation vulnerability in Schweitzer Engineering Laboratories SEL-411L could allow an attacker to perform reflection attacks against an authorized and authenticated user. See product Instruction Manual Appendix A dated 20230830 for more details...
CVE-2023-2267
An Improper Input Validation vulnerability in Schweitzer Engineering Laboratories SEL-411L could allow an attacker to perform reflection attacks against an authorized and authenticated user. See product Instruction Manual Appendix A dated 20230830 for more details...
CVE-2023-31177
An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for mor...
CVE-2023-31177
An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for mor...
CVE-2023-31176
An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details...
CVE-2023-2264
An improper input validation vulnerability in the Schweitzer Engineering Laboratories SEL-411L could allow a malicious actor to manipulate authorized users to click on a link that could allow undesired behavior. See product Instruction Manual Appendix A dated 20230830 for more details...
CVE-2023-2265
An Improper Restriction of Rendered UI Layers or Frames in the Schweitzer Engineering Laboratories SEL-411L could allow an unauthenticated attacker to perform clickjacking based attacks against an authenticated and authorized user. See product Instruction Manual Appendix A dated 20230830 for more...
Cross site scripting
An Improper neutralization of input during web page generation in the Schweitzer Engineering Laboratories SEL-411L could allow an attacker to generate cross-site scripting based attacks against an authorized and authenticated user. See product Instruction Manual Appendix A dated 20230830 for more...
Cross site scripting
An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for mor...