402 matches found
CVE-2023-31169
An Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...
CVE-2023-31167
Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL...
Path traversal
Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL...
Authentication flaw
A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...
Cross site request forgery (csrf)
A Cross-Site Request Forgery CSRF vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...
Hardcoded credentials
Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...
Input validation
An Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...
Design/Logic Flaw
Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A Cybersecurity tag dated 20230522 for more details. This issue affects...
Sql injection
An Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See...
Design/Logic Flaw
An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...
CVE-2023-34392 Missing Authentication for Critical Function
A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...
CVE-2023-34392
The CVE-2023-34392 entry describes a Missing Authentication for Critical Function flaw in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator, enabling an attacker to execute arbitrary commands on managed devices via an authorized operator. Affected software is SEL-5037 Grid Config...
CVE-2023-34391 Insecure Inherited Permissions
Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A Cybersecurity tag dated 20230522 for more details. This issue affects...
CVE-2023-34391
CVE-2023-34391 concerns an insecure inherited permissions vulnerability in Schweitzer Engineering Laboratories’ SEL-5033 AcSELerator RTAC Software running on Windows. The issue stems from insecure/inherited configuration file search paths, enabling manipulation of configuration files by an attack...
CVE-2023-31175 Execution with Unnecessary Privileges
An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...
CVE-2023-31175 Execution with Unnecessary Privileges
An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...
CVE-2023-31175
The CVE-2023-31175 issue affects SEL-5037 SEL Grid Configurator (pre-4.5.0.20). It is a privilege-related execution flaw that could allow an attacker to run arbitrary commands with the highest privileges on the host. Affected component is SEL Grid Configurator; root cause is improper privilege ha...
CVE-2023-31174 Cross-Site Request Forgery (CSRF)
A Cross-Site Request Forgery CSRF vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...
CVE-2023-31174 Cross-Site Request Forgery (CSRF)
A Cross-Site Request Forgery CSRF vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...
CVE-2023-31174
The CVE-2023-31174 entry describes a Cross-Site Request Forgery (CSRF) in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator. Affected product/version: SEL-5037 Grid Configurator prior to 4.5.0.20. Underlying issue: CSRF could enable an attacker to embed instructions that are exec...