Siemens Scalance S Security Module Firewall < 2.3.0.3 Brute Force
Binary data 720015.prm...
Siemens SCALANCE S602 Security module
Binary data 751132.prm...
Siemens SCALANCE S613 Denial of Service
Binary data 720080.prm...
The vulnerability of Scalance X industrial switches lies in the insufficient validation of input data, which allows attackers to bypass network firewalls.
The vulnerability of Scalance X industrial switches is related to insufficient verification of input data. Exploiting this vulnerability can allow a remote attacker to bypass network firewalls by transmitting malicious packets into the mirrored network...
Siemens SCALANCE, SIMATIC, RUGGEDCOM, and SINAMICS Products (Update F)
1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION : Exploitable remotely/low skill level to exploit/public exploits are available. Vendor : Siemens Equipment : SCALANCE, SIMATIC, RUGGEDCOM, and SINAMICS Products Vulnerabilities : Security Features 2. UPDATE INFORMATION This updated advisory is a...
Siemens SCALANCE and SIMATIC libcurl (Update B)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE and SIMATIC Vulnerability: Out-of-bounds Read 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-21-068-10 Siemens SCALANCE and...
Multiple SCALANCE X switches products mirror port isolation vulnerability
SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. A mirror port isolation vulnerability exists in several SCALANCE X switches products. The vulnerability is due to the monitoring barriers on the affected...
Siemens SCALANCE X (Update D)
1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SCALANCE X Vulnerability: Expected Behavior Violation 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled ICSA-19-085-01 Siemens SCALANCE X Update C that was published...
The vulnerability of Siemens SCALANCE S network gateways’ microprogramming software is related to insufficient protection of the WEB-page structure, allowing attackers to carry out cross-site scripting attacks.
The vulnerability of Siemens SCALANCE S network gateways’ microprogramming software is related to insufficient protection of the web page structure. Exploiting this vulnerability allows a remote attacker to perform cross-site scripting attacks...
CVE-2018-16555
A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...
CVE-2018-16555
A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...
Cross site scripting
A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...
CVE-2018-16555
CVE-2018-16555 affects Siemens SCALANCE S602, S612, S623 and S627-2M (all versions before 4.0.1.1). The vulnerability is an improper neutralization of input during web page generation, enabling cross-site scripting (XSS) if a user, who must be logged into the web interface, is tricked into clicki...
CVE-2018-16555
A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...
Multiple Siemens Products Cross-Site Scripting Vulnerabilities
Siemens SCALANCE S602 and others are Ethernet security modules from Siemens, Germany. A cross-site scripting vulnerability exists in several Siemens products, which can be exploited by remote attackers to inject arbitrary scripts via malicious links...
Siemens Patches Firewall Flaw That Put Operations at Risk
Siemens AG on Tuesday issued a slew of fixes addressing eight vulnerabilities spanning its industrial product lines. The most serious of the patched flaws include a cross-site scripting vulnerability in Siemens’ SCALANCE firewall product. The flaw could allow an attacker to gain unauthorized acce...
ICSA-18-317-04 Siemens SCALANCE S
1. EXECUTIVE SUMMARY CVSS v3 4.7 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SCALANCE S Vulnerability: Cross-site Scripting 2. RISK EVALUATION If an attacker tricks a user into clicking a malicious link, the device could allow arbitrary script injection XSS. 3. TECHNICAL DETAILS...
ICSA-18-282-02 Siemens SCALANCE W1750D
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely/public exploits are available Vendor: Siemens Equipment: SCALANCE W1750D Vulnerability: Cryptographic issues 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to decrypt TLS traffic. 3...
The vulnerability of Siemens SCALANCE X300 industrial switches’ web servers allows a hacker to trigger a service failure.
The vulnerability of Siemens SCALANCE X300 industrial switches involves insufficient validation of input data. Exploiting this vulnerability allows a malicious actor to trigger service interruptions by sending specially crafted packets to the TCP port 443...
Siemens SCALANCE X Switches Input Validation Vulnerability
Siemens SCALANCE X Switches is an industrial Ethernet switch from Siemens, Germany. An input validation vulnerability exists in Siemens SCALANCE X Switches, which could be exploited by an attacker with network access privileges to cause a denial of service...