Lucene search
+L

2220 matches found

OSV
OSV
added 2021/01/12 9:15 p.m.9 views

CVE-2020-15800

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-300 switch family incl. X408 and SIPLUS NET variants All versions V4.1.0. The webserver of t...

9.8CVSS7.1AI score0.01652EPSS
SaveExploits0References1
OSV
OSV
added 2021/01/12 9:15 p.m.6 views

CVE-2020-15799

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...

6.5CVSS6.8AI score0.0108EPSS
SaveExploits0References1
NVD
NVD
added 2021/01/12 9:15 p.m.32 views

CVE-2020-15800

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-300 switch family incl. X408 and SIPLUS NET variants All versions V4.1.0. The webserver of t...

9.8CVSS9.4AI score0.01652EPSS
SaveExploits0References1
NVD
NVD
added 2021/01/12 9:15 p.m.48 views

CVE-2020-25226

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The web server of the affected devices contains a vulnerability that may lead to a buffer overflow...

10CVSS9.6AI score0.01907EPSS
SaveExploits0References1
Prion
Prion
added 2021/01/12 9:15 p.m.31 views

Hardcoded credentials

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...

4.3CVSS5.4AI score0.01119EPSS
SaveExploits0References2Affected Software54
Prion
Prion
added 2021/01/12 9:15 p.m.26 views

Design/Logic Flaw

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-300 switch family incl. X408 and SIPLUS NET variants All versions V4.1.0. The webserver of t...

9.3CVSS9.3AI score0.01652EPSS
SaveExploits0References1Affected Software54
Prion
Prion
added 2021/01/12 9:15 p.m.28 views

Design/Logic Flaw

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...

7.1CVSS7AI score0.0108EPSS
SaveExploits0References1Affected Software54
Prion
Prion
added 2021/01/12 9:15 p.m.23 views

Buffer overflow

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The web server of the affected devices contains a vulnerability that may lead to a buffer overflow...

10CVSS9.4AI score0.01907EPSS
SaveExploits0References1Affected Software54
Prion
Prion
added 2021/01/12 9:15 p.m.23 views

Design/Logic Flaw

A vulnerability has been identified in SCALANCE X-200RNA switch family All versions V3.2.7, SCALANCE X-300 switch family incl. X408 and SIPLUS NET variants All versions V4.1.0. Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a...

4.3CVSS5.4AI score0.01176EPSS
SaveExploits0References2Affected Software8
CVE
CVE
added 2021/01/12 8:18 p.m.88 views

CVE-2020-25226

Siemens SCALANCE X products are affected by CVE-2020-25226: heap-based/buffer overflow in the devices’ web server. Affected: SCALANCE X-200 (incl. SIPLUS NET) below v5.2.5, SCALANCE X-200IRT below v5.5.0, and SCALANCE X-300 below v4.1.0 (X-300 also affected by CVE-2020-15800 per ICS advisory). Ex...

10CVSS9.3AI score0.01907EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2021/01/12 8:18 p.m.88 views

CVE-2020-15799

CVE-2020-15799 affects Siemens SCALANCE X-200 switch family (incl. SIPLUS NET) < v5.2.5 and SCALANCE X-200IRT

7.1CVSS6.3AI score0.0108EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2021/01/12 8:18 p.m.42 views

CVE-2020-15800

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-300 switch family incl. X408 and SIPLUS NET variants All versions V4.1.0. The webserver of t...

9.3AI score0.01652EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2021/01/12 8:18 p.m.41 views

CVE-2020-25226

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The web server of the affected devices contains a vulnerability that may lead to a buffer overflow...

9.5AI score0.01907EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2021/01/12 8:18 p.m.45 views

CVE-2020-15799

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0. The vulnerability could allow an unauthenticated attacker to reboot the device over the network by usin...

6.4AI score0.0108EPSS
SaveExploits0References1
CVE
CVE
added 2021/01/12 8:18 p.m.86 views

CVE-2020-15800

Siemens SCALANCE X products are affected by CVE-2020-15800. The web server on SCALANCE X-200 family (incl. SIPLUS NET), X-200IRT family, and X-300 family may experience a heap-based buffer overflow when receiving specially crafted requests, potentially causing the web server to stop temporarily. ...

9.8CVSS9.2AI score0.01652EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2021/01/12 12:0 a.m.109 views

CVE-2020-28391

Summary: CVE-2020-28391 affects Siemens SCALANCE X switches (X-200, X-200IRT, X-200RNA; incl. SIPLUS NET variants). Root cause: after factory reset, devices normally generate a new unique key, but when used with C-PLUG they ship a hardcoded private RSA key, enabling a man-in-the-middle and decryp...

5.9CVSS5.4AI score0.01119EPSS
SaveExploits0References2Affected Software1
NCSC
NCSC
added 2021/01/12 12:0 a.m.8 views

Vulnerabilities fixed in Siemens Scalance products

Siemens has fixed vulnerabilities in Scalance products. The vulnerabilities allow a malicious party to perform a denial-of-service and to bypass a security measure. circumvention. Siemens categorizes these vulnerabilities according to the CVSSv3 method with a highest score of 9.1. Siemens has...

9.8CVSS6.8AI score0.01652EPSS
SaveExploits0
CNNVD
CNNVD
added 2021/01/12 12:0 a.m.13 views

Siemens SCALANCE X-200IRT 缓冲区错误漏洞

SCALANCE X is a switch for connecting industrial components such as programmable logic controllers plc or human machine interfaces HMIs. The Scalance X Products heap buffer overflow vulnerability allows an attacker to cause a request for such a scenario on a web server by sending a specially...

10CVSS7.4AI score0.01907EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2021/01/12 12:0 a.m.35 views

CVE-2020-28391

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants All versions V5.2.5, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.5.0, SCALANCE X-200RNA switch family All versions V3.2.7. Devices create a new unique key upon factory reset...

5.5AI score0.01119EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2021/01/12 12:0 a.m.7 views

PT-2021-2203 · Siemens · Scalance X-200 +2

Name of the Vulnerable Software and Affected Versions: SCALANCE X-200 versions prior to V3.2.7 SCALANCE X-200IRT versions prior to V3.2.7 SCALANCE X-300 versions prior to V4.1.0 Description: The issue is related to the reset function of industrial switches, which does not generate a new...

5.9CVSS5.6AI score0.01176EPSS
SaveExploits0References5
Rows per page
Query Builder