2411 matches found
The vulnerability of the command-line interface of Siemens SCALANCE industrial switches allows a hacker to execute arbitrary commands.
The vulnerability of the command-line interface of Siemens SCALANCE industrial switches exists due to the lack of measures taken to protect the command-line interface. Exploitation of this vulnerability allows a malicious actor to execute arbitrary commands remotely...
Siemens SCALANCE and RUGGEDCOM Devices SSH Improper Restriction of Excessive Authentication Attempts (CVE-2021-25676)
A vulnerability has been identified in RUGGEDCOM RM1224 V6.3, SCALANCE M-800 V6.3, SCALANCE S615 V6.3, SCALANCE SC-600 All Versions = V2.1 and = V2.1 and V2.1.3. Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the...
Siemens SCALANCE S-600 Improper Neutralization of Script-Related HTML Tags in a Web Page (CVE-2019-6585)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1, SCALANCE S627-2M All version...
Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13925)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. This plug...
Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13926)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold r...
Siemens SCALANCE XM-400 and XR-500 Devices Incorrect Calculation (CVE-2020-28393)
An unauthenticated remote attacker could create a permanent denial-of- service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4. This plugin only works with...
Siemens SCALANCE X-200RNA Switch Devices Path Traversal (CVE-2019-6111)
An issue was discovered in OpenSSH 7.9. Due to the scp implementation being derived from 1983 rcp, the server chooses which files/directories are sent to the client. However, the scp client only performs cursory validation of the object name returned only directory traversal attacks are prevented...
Siemens SCALANCE W1750D Command Injection (CVE-2018-7084)
A command injection vulnerability is present that permits an unauthenticated user with access to the Aruba Instant web interface to execute arbitrary system commands within the underlying operating system. An attacker could use this ability to copy files, read configuration, write files, delete...
Siemens TCP Event Service of SCALANCE And RUGGEDCOM Devices Improper Input Validation (CVE-2022-31766)
A vulnerability has been identified in RUGGEDCOM RM1224 LTE4G EU All versions = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 V2.0, SCALANCE WUM766-1 US All...
Siemens SCALANCE W1750D Devices
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens SCALANCE Third-Party
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens SCALANCE, RUGGEDCOM Third-Party
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in SCALANCE, among others, RuggedCom, SIMATIC, SIPROTEC and Mendix. The vulnerabilities allow a malicious party potentially capable of carrying out attacks that lead to the following categories of damage: Denial-of-Service DoS. Accessing sensitive data Bypassing...
The vulnerability in the web interface for controlling Siemens SCALANCE industrial switches allows a hacker to execute arbitrary code.
The vulnerability of the web interface for controlling Siemens SCALANCE microprogrammable industrial controllers exists due to the lack of measures taken to protect the website structure. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...
The vulnerability in the web interface for controlling Siemens SCALANCE industrial switches allows a hacker to execute arbitrary code.
The vulnerability in the web interface for controlling Siemens SCALANCE microprogrammable industrial controllers exists due to the lack of measures taken to protect the website structure. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...
Siemens SCALANCE X-200RNA Switch Devices Integer Overflow or Wraparound (CVE-2019-16905)
OpenSSH 7.7 through 7.9 and 8.x before 8.1, when compiled with an experimental key type, has a pre-authentication integer overflow if a client or server is configured to use a crafted XMSS key. This leads to memory corruption and local code execution because of an error in the XMSS key parsing...
Siemens SCALANCE X-200RNA Switch Devices Concurrent Execution Using Shared Resource with Improper Synchronization (CVE-2018-15473)
OpenSSH through 7.7 is prone to a user enumeration vulnerability due to not delaying bailout for an invalid authenticating user until after the packet containing the request has been fully parsed, related to auth2-gss.c, auth2-hostbased.c, and auth2-pubkey.c. - OpenSSH through 7.7 is prone to a...
Siemens SCALANCE X-200RNA Switch Devices Incorrect Authorization (CVE-2018-20685)
In OpenSSH 7.9, scp.c in the scp client allows remote SSH servers to bypass intended access restrictions via the filename of . or an empty filename. The impact is modifying the permissions of the target directory on the client side. - In OpenSSH 7.9, scp.c in the scp client allows remote SSH...
Siemens SCALANCE X-200RNA Switch Devices Improper Encoding or Escaping of Output (CVE-2019-6109)
An issue was discovered in OpenSSH 7.9. Due to missing character encoding in the progress display, a malicious server or Man-in-The- Middle attacker can employ crafted object names to manipulate the client output, e.g., by using ANSI control codes to hide additional files being transferred. This...
Siemens SCALANCE X-200RNA Switch Devices Inappropriate Encoding For Output Context (CVE-2019-6110)
In OpenSSH 7.9, due to accepting and displaying arbitrary stderr output from the server, a malicious server or Man-in- The-Middle attacker can manipulate the client output, for example to use ANSI control codes to hide additional files being transferred. - In OpenSSH 7.9, due to accepting and...