Lucene search
+L

2220 matches found

Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.32 views

Siemens SCALANCE W1750D Exposure of Sensitive Information to an Unauthorized Actor (CVE-2018-7083)

If a process running within Aruba Instant crashes, it may leave behind a core dump, which contains the memory contents of the process at the time it crashed. It was discovered that core dumps are stored in a way that unauthenticated users can access them through the Aruba Instant web interface...

7.5CVSS7.1AI score0.0185EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.22 views

Siemens SCALANCE W1750D Command Injection (CVE-2021-37730)

A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant IAP versions: Aruba Instant 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.20 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant...

9CVSS7.4AI score0.03055EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.32 views

Siemens SCALANCE W1750D OS Command Injection (CVE-2021-37732)

A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant IAP versions: Aruba Instant 6.4.x.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x.x: 6.5.4.18 and below; Aruba Instant 8.5.x.x: 8.5.0.11 and below; Aruba Instant 8.6.x.x: 8.6.0.6 and below; Aruba Instant...

9CVSS7.6AI score0.03055EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.25 views

Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25156)

A remote arbitrary directory create vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below;...

4.9CVSS6.7AI score0.3965EPSS
SaveExploits4References5
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.34 views

Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2022-37891)

Unauthenticated buffer overflow vulnerabilities exist within the Aruba InstantOS and ArubaOS 10 web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS...

9.8CVSS7.3AI score0.01133EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.28 views

Siemens SCALANCE Improper Limitation of a Pathname to a Restricted Directory (CVE-2021-37728)

A remote path traversal vulnerability was discovered in Aruba Operating System Software versions: Prior to 8.8.0.1, 8.7.1.4, 8.6.0.11, 8.5.0.13. Aruba has released patches for ArubaOS that address this security vulnerability. This plugin only works with Tenable.ot. Please visit...

8.5CVSS6.9AI score0.01054EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.23 views

Siemens SCALANCE W1750D Command Injection (CVE-2021-25150)

A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.4 and below. Aru...

9CVSS7.7AI score0.0282EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.27 views

Siemens SCALANCE M875 Cross-Site Request Forgery (CVE-2018-11447)

A vulnerability has been identified in SCALANCE M875 All versions. The web interface on port 443/tcp could allow a Cross-Site Request Forgery CSRF attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, wh...

8.8CVSS7.7AI score0.00584EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.19 views

Siemens SCALANCE W1750D Improper Limitation of a Pathname to a Restricted Directory (CVE-2021-37734)

A remote unauthorized read access to files vulnerability was discovered in Aruba Instant versions: 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.19 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant 8.7.x.x: 8.7.1.3 a...

6.5CVSS6.6AI score0.00977EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.14 views

Siemens SCALANCE LPE9403 Race Condition (CVE-2021-36221)

Go before 1.15.15 and 1.16.x before 1.16.7 has a race condition that can lead to a net/http/httputil ReverseProxy panic upon an ErrAbortHandler abort. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

5.9CVSS7.3AI score0.03128EPSS
SaveExploits0References13
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:00 a.m.29 views

Siemens SCALANCE Command Injection (CVE-2021-37720)

A remote arbitrary command execution vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software versions: Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.4, 8.6.0.9, 8.5.0.13, 8.3.0.16, 6.5.4.20, 6.4.4.25. Aruba has released patches for Aruba SD-WAN Software and...

9CVSS7.2AI score0.03055EPSS
SaveExploits0References4
ICS
ICS
added 2023/04/11 12:00 a.m.72 views

Siemens SCALANCE Switch Families

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

9.6AI score
SaveExploits0References10
ICS
ICS
added 2023/04/11 12:00 a.m.41 views

Siemens SCALANCE X-200IRT Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

7.4CVSS7AI score0.00256EPSS
SaveExploits0References12
ICS
ICS
added 2023/04/11 12:00 a.m.41 views

Siemens SCALANCE XCM332

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

9.8CVSS9.3AI score0.3216EPSS
SaveExploits6References12
BDU FSTEC
BDU FSTEC
added 2023/04/10 12:00 a.m.16 views

The vulnerability of the command-line interface of Siemens SCALANCE industrial switches allows a hacker to execute arbitrary commands.

The vulnerability of the command-line interface of Siemens SCALANCE industrial switches exists due to the lack of measures taken to protect the command-line interface. Exploitation of this vulnerability allows a malicious actor to execute arbitrary commands remotely...

9CVSS7.9AI score0.0282EPSS
SaveExploits0References5Affected Software2
Tenable Nessus
Tenable Nessus
added 2023/03/27 12:00 a.m.28 views

Siemens SCALANCE S-600 Improper Neutralization of Script-Related HTML Tags in a Web Page (CVE-2019-6585)

A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1, SCALANCE S627-2M All version...

6.1CVSS6.6AI score0.00739EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/03/27 12:00 a.m.24 views

Siemens SCALANCE XM-400 and XR-500 Devices Incorrect Calculation (CVE-2020-28393)

An unauthenticated remote attacker could create a permanent denial-of- service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4. This plugin only works with...

7.5CVSS7.4AI score0.01629EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/03/27 12:00 a.m.26 views

Siemens SCALANCE and RUGGEDCOM Devices SSH Improper Restriction of Excessive Authentication Attempts (CVE-2021-25676)

A vulnerability has been identified in RUGGEDCOM RM1224 V6.3, SCALANCE M-800 V6.3, SCALANCE S615 V6.3, SCALANCE SC-600 All Versions = V2.1 and = V2.1 and V2.1.3. Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the...

7.5CVSS7.1AI score0.0129EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/03/27 12:00 a.m.28 views

Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13926)

A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold r...

7.8CVSS7AI score0.015EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/03/27 12:00 a.m.23 views

Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13925)

A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. This plug...

7.5CVSS7.3AI score0.01452EPSS
SaveExploits0References3
Rows per page
Query Builder