added 2023/11/14 11:04 a.m.126 views

CVE-2023-44322

CVE-2023-44322 is an unchecked return value vulnerability in Siemens SCALANCE/RUGGEDCOM devices that can be triggered by an invalid SMTP server response, potentially allowing an authenticated attacker with network access to disable email/notification alerts. Connected advisories confirm the affec...

5.9CVSS4.6AI score0.00879EPSS
SaveExploits0References6Affected Software1
CVE
CVE
added 2023/11/14 11:04 a.m.107 views

CVE-2023-44321

CVE-2023-44321 affects Siemens industrial devices (e.g., RUGGEDCOM RM1224, SCALANCE M-800 family and related models). The root cause is improper validation of input length in the web interface during configuration changes, which can be exploited by an authenticated attacker to cause a denial-of-s...

6.5CVSS4.9AI score0.01001EPSS
SaveExploits0References7Affected Software1
Vulnrichment
Vulnrichment
added 2023/11/14 11:03 a.m.2 views

CVE-2023-44320

A vulnerability has been identified in RUGGEDCOM RM1224 LTE4G EU 6GK6108-4AM00-2BA2 All versions V7.2.2, RUGGEDCOM RM1224 LTE4G NAM 6GK6108-4AM00-2DA2 All versions V7.2.2, SCALANCE M804PB 6GK5804-0AP00-2AA2 All versions V7.2.2, SCALANCE M812-1 ADSL-Router 6GK5812-1AA00-2AA2 All versions V7.2.2,...

4.3CVSS5.4AI score0.00643EPSS
SaveExploits0References7
CVE
CVE
added 2023/11/14 11:03 a.m.104 views

CVE-2023-44320

CVE-2023-44320 affects Siemens SCALANCE and RUGGEDCOM devices (e.g., RM1224 LTE EU/NAM, SCALANCE M8xx/MUm/WM/ S-series) with all versions before V7.2.2. The issue is improper authentication validation in the web interface, allowing an authenticated attacker to influence the administrator’s UI. Ex...

4.3CVSS4.3AI score0.00643EPSS
SaveExploits0References7Affected Software1
CVE
CVE
added 2023/11/14 11:03 a.m.108 views

CVE-2023-44319

CVE-2023-44319 affects Siemens SCALANCE and RUGGEDCOM devices (e.g., RM1224 LTE, M8xx/UM8xx/SCALANCE S615/WAB/WUM/WAM series). Root cause: use of a weak checksum algorithm to protect exported configuration backups, enabling an authenticated admin or a tricked admin to upload a modified backup and...

6.9CVSS5.2AI score0.00446EPSS
SaveExploits0References6Affected Software1
CVE
CVE
added 2023/11/14 11:03 a.m.114 views

CVE-2023-44318

CVE-2023-44318 affects Siemens SCALANCE and RUGGEDCOM devices (e.g., SCALANCE XB205-3, M-series, S615, RM1224, etc.) where a hard-coded cryptographic key obfuscates configuration backups. This allows an authenticated admin or someone with a backup to extract configuration information from the exp...

6.9CVSS4.8AI score0.00688EPSS
SaveExploits0References5Affected Software1
Vulnrichment
Vulnrichment
added 2023/11/14 11:03 a.m.9 views

CVE-2023-44317

A vulnerability has been identified in RUGGEDCOM RM1224 LTE4G EU 6GK6108-4AM00-2BA2 All versions V7.2.2, RUGGEDCOM RM1224 LTE4G NAM 6GK6108-4AM00-2DA2 All versions V7.2.2, SCALANCE M804PB 6GK5804-0AP00-2AA2 All versions V7.2.2, SCALANCE M812-1 ADSL-Router 6GK5812-1AA00-2AA2 All versions V7.2.2,...

8.6CVSS7.1AI score0.00376EPSS
SaveExploits0References6
CVE
CVE
added 2023/11/14 11:03 a.m.103 views

CVE-2023-44317

CVE-2023-44317 affects Siemens SCALANCE and RUGGEDCOM devices. The flaw is that affected products do not properly validate uploaded X509 certificates, which could allow an attacker with administrative privileges to execute arbitrary code on the device. Affected versions are listed as all versions...

8.6CVSS7.3AI score0.00376EPSS
SaveExploits0References6Affected Software1
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.8 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

8.8CVSS7AI score0.00666EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.9 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

4.3CVSS6.7AI score0.00643EPSS
SaveExploits0References9
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.9 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

6.9CVSS6.8AI score0.00446EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2023/11/14 12:00 a.m.13 views

PT-2023-6994 · Siemens · Scalance M812-1 +15

Name of the Vulnerable Software and Affected Versions: RUGGEDCOM RM1224 LTE4G EU versions V7.2.2 RUGGEDCOM RM1224 LTE4G NAM versions V7.2.2 SCALANCE M804PB versions V7.2.2 SCALANCE M812-1 ADSL-Router versions V7.2.2 SCALANCE M816-1 ADSL-Router versions V7.2.2 SCALANCE M826-2 SHDSL-Router versions...

4.3CVSS6.9AI score0.00643EPSS
SaveExploits0References12
NCSC
NCSC
added 2023/11/14 12:00 a.m.13 views

Vulnerabilities fixed in Siemens products

Siemens has fixed vulnerabilities in several products including. SIMATIC, SINEC, SIPROTEC and RUGGEDCOM. The vulnerabilities allow a malicious party potentially able to launch attacks that could lead to the following categories of damage: Denial-of-Service DoS Manipulation of data Circumvention o...

9.8CVSS8.3AI score0.99735EPSS
SaveExploits20
Positive Technologies
Positive Technologies
added 2023/11/14 12:00 a.m.11 views

PT-2023-6993 · Siemens · Scalance M826-2 Shdsl-Router +16

Name of the Vulnerable Software and Affected Versions: RUGGEDCOM RM1224 LTE4G EU versions V8.0 RUGGEDCOM RM1224 LTE4G NAM versions V8.0 SCALANCE M804PB versions V8.0 SCALANCE M812-1 ADSL-Router versions V8.0 SCALANCE M816-1 ADSL-Router versions V8.0 SCALANCE M826-2 SHDSL-Router versions V8.0...

5.9CVSS6.6AI score0.00879EPSS
SaveExploits0References11
ICS
ICS
added 2023/11/14 12:00 a.m.25 views

Siemens SCALANCE W700

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

7.5CVSS7.1AI score0.00889EPSS
SaveExploits1References12
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.12 views

Siemens SCALANCE 注入漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

9.4CVSS7.1AI score0.01352EPSS
SaveExploits0References8
CNNVD
CNNVD
added 2023/11/14 12:00 a.m.8 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

8.6CVSS7.7AI score0.00376EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2023/11/14 12:00 a.m.13 views

PT-2023-6995 · Siemens · Scalance M826-2 Shdsl-Router +16

Name of the Vulnerable Software and Affected Versions: RUGGEDCOM RM1224 LTE4G EU versions V8.0 RUGGEDCOM RM1224 LTE4G NAM versions V8.0 SCALANCE M804PB versions V8.0 SCALANCE M812-1 ADSL-Router versions V8.0 SCALANCE M816-1 ADSL-Router versions V8.0 SCALANCE M826-2 SHDSL-Router versions V8.0...

9.4CVSS9AI score0.01352EPSS
SaveExploits0References12
ICS
ICS
added 2023/11/14 12:00 a.m.67 views

Siemens SCALANCE Family Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

9.4AI score
SaveExploits0References12
Positive Technologies
Positive Technologies
added 2023/11/14 12:00 a.m.5 views

PT-2023-6991 · Siemens · Scalance M826-2 Shdsl-Router +14

Name of the Vulnerable Software and Affected Versions: SCALANCE M804PB versions prior to V8.0 SCALANCE M812-1 ADSL-Router versions prior to V8.0 SCALANCE M816-1 ADSL-Router versions prior to V8.0 SCALANCE M826-2 SHDSL-Router versions prior to V8.0 SCALANCE M874-2 versions prior to V8.0 SCALANCE...

6.9CVSS6.6AI score0.00446EPSS
SaveExploits0References12