•added 2017/02/13 9:00 p.m.•78 views

CVE-2017-5161

CVE-2017-5161 concerns a DLL hijacking (Uncontrolled Search Path Element) vulnerability in Sielco Sistemi Winlog Lite/Pro SCADA software prior to 3.02.01. The root cause is an uncontrolled search path element that could allow a local attacker to load a malicious DLL and gain the same privileges a...

9.3CVSS6.9AI score0.00938EPSS
SaveExploits1References2Affected Software2
Cvelist
Cvelist
•added 2017/02/13 9:00 p.m.•34 views

CVE-2017-5161

An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element DLL Hijacking vulnerability has been identified. Exploitation of this vulnerability could...

7AI score0.00938EPSS
SaveExploits1References2
CVE
CVE
•added 2017/02/13 9:00 p.m.•97 views

CVE-2016-9360

The CVE-2016-9360 issue affects GE Proficy HMI/SCADA iFIX (Version 5.8 SIM 13 and earlier), CIMPLICITY (Version 9.0 and earlier), and Historian (Version 6.0 and earlier). Root cause: Insufficiently protected credentials enabling password retrieval when an attacker has access to an authenticated s...

6.7CVSS6.3AI score0.00369EPSS
SaveExploits0References3Affected Software3
Positive Technologies
Positive Technologies
•added 2017/02/13 12:00 a.m.•6 views

PT-2017-16355

Name of the Vulnerable Software and Affected Versions Sielco Sistemi Winlog Lite SCADA Software versions prior to 3.02.01 Sielco Sistemi Winlog Pro SCADA Software versions prior to 3.02.01 Description An uncontrolled search path element, also known as DLL Hijacking, has been identified in the...

9.3CVSS0.00938EPSS
SaveExploits1References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/02/13 12:00 a.m.•8 views

CVE-2017-5161: Uncontrolled Search Path Element

An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element DLL Hijacking vulnerability has been identified. Exploitation of this vulnerability could...

9.3CVSS5.7AI score0.00938EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/02/13 12:00 a.m.•8 views

CVE-2016-9360: Insufficiently Protected Credentials

An issue was discovered in General Electric GE Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has acces...

6.7CVSS5.7AI score0.00369EPSS
SaveExploits0References2
CNVD
CNVD
•added 2017/02/10 12:00 a.m.•22 views

Multiple SQL Injection Vulnerabilities in Ecava IntegraXor

Ecava IntegraXor is a set of Web-based tools for creating and running HMI interfaces for SCADA systems. Ecava IntegraXor suffers from multiple SQL injection vulnerabilities that stem from a failure to properly validate a SQL query before using user input. An attacker could use this vulnerability ...

9.8CVSS8AI score0.01659EPSS
SaveExploits0References1
ICS
ICS
•added 2017/02/07 12:00 a.m.•91 views

ICSA-17-038-01_Sielco Sistemi Winlog SCADA Software

CVSS v3 7.2 Vendor: Sielco Sistemi Equipment: Winlog SCADA Software Vulnerability: Uncontrolled Search Path Element AFFECTED PRODUCTS The following Sielco Sistemi products are affected: Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to...

9.3CVSS7.3AI score0.00938EPSS
SaveExploits1References2
ThreatPost
ThreatPost
•added 2017/02/06 2:20 p.m.•18 views

ICS, SCADA Security Woes Linger On

A handful of worrisome vulnerabilities in Honeywell building automation system software disclosed last week are case in point of how far the industry continues to lag in securing SCADA and industrial control systems. Honeywell published in September new firmware that patches vulnerabilities...

SaveExploits0References4
ThreatPost
ThreatPost
•added 2017/02/03 3:03 p.m.•14 views

Honeywell SCADA Controllers Exposed Passwords in Clear Text

A series of remotely exploitable vulnerabilities exist in a popular web-based SCADA system made by Honeywell that make it easy to expose passwords and in turn, give attackers a foothold into the vulnerable network. The flaws exist in some versions of Honeywell’s XL Web II controllers, systems...

7.2AI score
SaveExploits0References9
CNVD
CNVD
•added 2017/01/17 12:00 a.m.•15 views

Scada-os Configuration Software dll Hijacking Vulnerability

Scada-os is a SCADA system developed by several SCADA configuration software engineers. The TsStudio.exe component of the Scada-os configuration software is not safe to load library files, so an attacker can construct a malicious application and place it in a specific path, which will allow the...

7.1AI score
SaveExploits0
ICS
ICS
•added 2017/01/17 12:00 a.m.•106 views

GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian Vulnerability

OVERVIEW This advisory was originally posted to the NCCIC Portal on December 1, 2016, and is being released to the ICS-CERT web site. GE has reported an insufficiently protected credentials vulnerability in Proficy Human-Machine Interface/Supervisory Control and Data Acquisition HMI/SCADA iFIX,...

6.7CVSS1AI score0.00369EPSS
SaveExploits0References26
ICS
ICS
•added 2017/01/17 12:00 a.m.•105 views

GE Proficy HMI/SCADA iFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian Vulnerability (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-336-05 GE Proficy HMI/SCADA IFIX, Proficy HMI/SCADA CIMPLICITY, and Proficy Historian Vulnerability that was published January 17, 2017, on the NCCIC/ICS-CERT web site. GE has reported an insufficiently protecte...

6.7CVSS1.1AI score0.00369EPSS
SaveExploits0References27
Tenable Nessus
Tenable Nessus
•added 2017/01/09 12:00 a.m.•17 views

Advantech WebAccess Version Detection (SCADA)

Binary data 9860.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2017/01/09 12:00 a.m.•13 views

Advantech WebAccess Detection (SCADA)

Binary data 9859.prm...

7.3AI score
SaveExploits0References1
The Hacker News
The Hacker News
•added 2016/12/20 9:49 p.m.•30 views

Hackers Suspected of Causing Second Power Outage in Ukraine

The same group of hackers that caused the power outage across several regions in Ukraine last Christmas holidays might have once again shut down power supply in northern Ukraine during the weekend. According to Ukrainian energy provider Ukrenergo, a cyber attack on Kyiv's power grid may have caus...

6.6AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2016/12/12 12:00 a.m.•29 views

Siemens SIMATIC STEP 7 (TIA Portal) < 14 Unquoted Service Path Local Privilege Escalation (SSA-701708)

Binary data scadasiemenstiastep7SSA-701708.nbin...

6.9CVSS7.3AI score0.00378EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2016/12/12 12:00 a.m.•25 views

Siemens SIMATIC WinCC (TIA Portal) < 14 Unquoted Service Path Local Privilege Escalation (SSA-701708)

Binary data scadasiemenstiawinccSSA-701708.nbin...

6.9CVSS7.3AI score0.00378EPSS
SaveExploits0References3
Symantec
Symantec
•added 2016/11/30 8:00 a.m.•61 views

SA135 : OpenSSL Vulnerabilities 10-Nov-2016

SUMMARY Blue Coat products using affected versions of OpenSSL are susceptible to multiple vulnerabilities. A remote attacker can exploit these vulnerabilities to cause denial of service and obtain SSL/TLS session key information. AFFECTED PRODUCTS The following products are vulnerable: Director -...

5CVSS7.1AI score0.32389EPSS
SaveExploits4Affected Software7
zdt
zdt
•added 2016/11/23 12:00 a.m.•67 views

UCanCode - Multiple Vulnerabilities

Exploit for windows platform in category dos / poc UCanCode multiple vulnerabilities Url: http://www.hmi-software.com/ http://www.ucancode.net/index.htm http://www.ucancode.net/bbs/zhuce/login.htm Description: Form vendor's web page "UCanCode Software is a Market Leading provider of HMI & SCADA,...

7AI score
SaveExploits0