Lucene search
+L

3469 matches found

Check Point Advisories
Check Point Advisories
added 2021/11/28 12:0 a.m.34 views

IPack SCADA Automation Software SQL Injection (CVE-2021-3958)

An SQL injection vulnerability exists in IPack SCADA Automation. Successful exploitation of this vulnerability would allow a remote attacker to execute arbitrary SQL commands on the affected system...

7.5CVSS10AI score0.14501EPSS
SaveExploits1
CNVD
CNVD
added 2021/11/17 12:0 a.m.66 views

Siemens SIMATIC PCS 7 and SIMATIC WinCC Path Traversal Vulnerability (CNVD-2021-89422)

Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, a German company. SIMATIC PCS 7 is a process control system and SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. A path traversal vulnerability exists in SIMATIC PCS 7 and SIMATIC WinCC. The...

9.9CVSS3AI score0.01233EPSS
SaveExploits0References1
OSV
OSV
added 2021/11/16 4:15 p.m.8 views

CVE-2021-3958

Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0...

9.8CVSS5.8AI score0.14501EPSS
SaveExploits1References1
Prion
Prion
added 2021/11/16 4:15 p.m.21 views

Sql injection

Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0...

7.5CVSS9.7AI score0.14501EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2021/11/16 3:46 p.m.58 views

CVE-2021-3958

CVE-2021-3958 is a SQL injection vulnerability in IPack SCADA Automation Software caused by improper handling of parameters. It affects IPack SCADA Software versions prior to 1.1.0 and is described as Blind SQL Injection with potential for remote exploitation over network. Public records indicate...

9.8CVSS9.9AI score0.14501EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
added 2021/11/16 3:46 p.m.32 views

CVE-2021-3958 SQL Injection Vulnerability in Ipack SCADA Software

Improper Handling of Parameters vulnerability in Ipack Automation Systems Ipack SCADA Software allows : Blind SQL Injection.This issue affects Ipack SCADA Software: from unspecified before 1.1.0...

9.8CVSS10AI score0.14501EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
added 2021/11/16 12:0 a.m.7 views

PT-2021-22653 · Unknown · Ipack Scada

Name of the Vulnerable Software and Affected Versions: Ipack SCADA Software versions prior to 1.1.0 Description: The issue is related to improper handling of parameters, allowing Blind SQL Injection. This can potentially be exploited to extract or modify sensitive data from the database...

9.8CVSS7.6AI score0.14501EPSS
SaveExploits1References3
CNNVD
CNNVD
added 2021/11/16 12:0 a.m.8 views

iPack SCADA Automation software SQL注入漏洞

iPack SCADA Automation software is used by the Turkish company iPack to enable tracking and management of data from remote points and to intervene in the system. The SQL injection vulnerability in iPack SCADA Automation software stems from improper cleanup. iPack SCADA Automation software is...

9.8CVSS8.6AI score0.14501EPSS
SaveExploits1References2
CNVD
CNVD
added 2021/11/13 12:0 a.m.88 views

Siemens SIMATIC PCS 7 and SIMATIC WinCC Path Traversal Vulnerability

Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, a German company. SIMATIC PCS 7 is a process control system and SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. A path traversal vulnerability exists in SIMATIC PCS 7 and SIMATIC WinCC, which stems...

7.7CVSS2.7AI score0.01137EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/11/13 12:0 a.m.57 views

Siemens SIMATIC PCS 7 and SIMATIC WinCC Log Information Disclosure Vulnerability

Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, a German company.SIMATIC PCS 7 is a process control system.SIMATIC WinCC is an automated data acquisition and monitoring SCADA system.Siemens SIMATIC PCS and A log information disclosure vulnerability exists in Siemens SIMATIC...

5.5CVSS1.7AI score0.00233EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2021/11/11 12:0 a.m.20 views

The vulnerability of the KrugCorrectTime.exe software of the SCADA system “KRUG-2000” lies in the lack of authentication for a critical function, allowing a intruder to cause a malfunction in the normal operation of the SCADA system.

The vulnerability of the KrugCorrectTime.exe software component of the SCADA system “KRUG-2000” lies in the lack of authentication for a critical function. Exploiting this vulnerability could allow an intruder to cause malfunctions in the normal operation of the SCADA system...

7.7CVSS5.5AI score
SaveExploits0
ICS
ICS
added 2021/11/09 12:0 a.m.156 views

Siemens SIMATIC WinCC (Update E)

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

9.9CVSS7.5AI score0.01233EPSS
SaveExploits0References12
CNVD
CNVD
added 2021/11/05 12:0 a.m.31 views

DAQFactory Deserialization Vulnerability

DAQFactory is a software and application development platform that provides a variety of tools that allow you to easily create HMI/SCADA applications. A deserialization vulnerability exists in DAQFactory 18.1 Build 2347 and earlier versions. An attacker can exploit this vulnerability to corrupt...

7.8CVSS7.6AI score0.00765EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/11/05 12:0 a.m.43 views

DAQFactory Man-in-the-Middle Attack Vulnerability

DAQFactory is a software and application development platform that provides a variety of tools that allow you to easily create HMI/SCADA applications. A man-in-the-middle attack vulnerability exists in DAQFactory 18.1 Build 2347 and earlier versions. The vulnerability can be exploited by an...

6.3CVSS6.1AI score0.0057EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/11/05 12:0 a.m.40 views

Unspecified vulnerability in DAQFactory

DAQFactory is a software and application development platform that provides a variety of tools that allow you to easily create HMI/SCADA applications. A security vulnerability exists in DAQFactory 18.1 Build 2347 and earlier versions. The vulnerability can be exploited by an attacker via a...

7.8CVSS7.7AI score0.00766EPSS
SaveExploits0References1
ICS
ICS
added 2021/10/21 12:0 a.m.47 views

ICONICS GENESIS64 and Mitsubishi Electric MC Works64

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: ICONICS, Mitsubishi Electric Equipment: ICONICS GENESIS64, Mitsubishi Electric MC Works64 Vulnerabilities: Out-of-bounds Read, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities may...

7.8CVSS5.4AI score0.02743EPSS
SaveExploits0References5
Schneier on Security
Schneier on Security
added 2021/10/19 11:7 a.m.19 views

Ransomware Attacks against Water Treatment Plants

According to a report from CISA last week, there were three ransomware attacks against water treatment plants last year. WWS Sector cyber intrusions from 2019 to early 2021 include: In August 2021, malicious cyber actors used Ghost variant ransomware against a California-based WWS facility. The...

6.8AI score
SaveExploits0
HackRead
HackRead
added 2021/10/15 3:38 p.m.21 views

CISA – Ransomware targeted SCADA systems of 3 US water facilities

By Deeba Ahmed US has warned of more ransomware attacks on IT and OT networks of country's Water and Wastewater Systems WWS Sector facilities. This is a post from HackRead.com Read the original post: CISA - Ransomware targeted SCADA systems of 3 US water facilities...

6.9AI score
SaveExploits0
NVD
NVD
added 2021/10/15 1:15 p.m.35 views

CVE-2021-38431

An authenticated user using Advantech WebAccess SCADA in versions 9.0.3 and prior can use API functions to disclose project names and paths from other users...

4.3CVSS0.00698EPSS
SaveExploits0References1
Prion
Prion
added 2021/10/15 1:15 p.m.18 views

Design/Logic Flaw

An authenticated user using Advantech WebAccess SCADA in versions 9.0.3 and prior can use API functions to disclose project names and paths from other users...

4CVSS4.4AI score0.00698EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder