4118 matches found
CVE-2023-0956
CVE-2023-0956 affects TEL-STER TelWin SCADA WebInterface, with a path traversal vulnerability (CWE-35) caused by external input not neutralizing path separators. This allows an unauthenticated, remote attacker to read files on affected systems. Affected versions span TelWin SCADA WebInterface 3.2...
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems ICS advisories on August 3, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-215-01 Mitsubishi Electric GOT2000 and GOT SIMPLE ICSA-23-215-02 Mitsubishi Electric GT...
TEL-STER TelWin SCADA WebInterface
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: TEL-STER Sp. z o. o. Equipment: TelWin SCADA WebInterface Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to read...
PT-2023-4280
Name of the Vulnerable Software and Affected Versions TEL-STER TelWin SCADA WebInterface affected versions not specified Description The issue is related to the TEL-STER TelWin SCADA WebInterface, where external input could be used to construct paths to files and directories without properly...
CVE-2023-0956: Improper Limitation of a Pathname to a Restricted Directory
External input could be used on TEL-STER TelWin SCADA WebInterface to construct paths to files and directories without properly neutralizing special elements within the pathname, which could allow an unauthenticated attacker to read files on the system...
CVE-2023-1437
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute...
CVE-2023-3329
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
Design/Logic Flaw
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute...
Path traversal
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
CVE-2023-1437 CVE-2023-1437
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute...
CVE-2023-1437
Advantech WebAccess/SCADA (all versions prior to 9.1.4) is affected by CVE-2023-1437 due to untrusted pointer handling in RPC arguments, enabling a remote attacker to access the remote file system and potentially execute commands or overwrite files. The root cause is untrusted pointers dereferenc...
CVE-2023-3329 CVE-2023-3329
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
CVE-2023-3329 CVE-2023-3329
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
CVE-2023-3329
CVE-2023-3329 affects SpiderControl SCADA Webserver versions 2.08 and prior. The vulnerability is a path traversal (CWE-22) flaw in the HMI file upload feature, allowing an attacker with administrative privileges to overwrite files on the webserver, potentially creating size-zero files anywhere a...
Advantech WebAccess/SCADA Buffer Error Vulnerability
Advantech WebAccess/SCADA is a set of SCADA software based on browser architecture from Advantech, China. The software supports dynamic graphical display and real-time data control, and provides remote control and management of automation devices. A buffer error vulnerability exists in Advantech...
CVE-2023-3329: Improper Limitation of a Pathname to a Restricted Directory
SpiderControl SCADA Webserver versions 2.08 and prior are vulnerable to path traversal. An attacker with administrative privileges could overwrite files on the webserver using the HMI's upload file feature. This could create size zero files anywhere on the webserver, potentially overwriting syste...
CVE-2023-1437: Untrusted Pointer Dereference
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute...
The vulnerability of the SpiderControl SCADA Web Server arises from an incorrect restriction on the path to the restricted access catalog. This allows a intruder to cause a service failure.
The vulnerability of the SpiderControl SCADA Web Server exists due to an incorrect restriction on the path to the restricted catalog. Exploiting this vulnerability could allow a malicious actor to cause service failures...
PT-2023-4939 · Advantech · Webaccess/Scada
Name of the Vulnerable Software and Affected Versions: Advantech WebAccess/SCADA versions prior to 9.1.4 Description: The issue is related to the use of untrusted pointers in the software. Specifically, the RPC arguments sent by the client could contain raw memory pointers that the server uses...
The vulnerability of the software and hardware components of SCADA systems, such as the ABB Pulsar Plus System Controller NE843_S, Infinity DC Power Plant H5692448 G104, Infinity DC Power Plant H5692448 G842, Infinity DC Power Plant H5692448 G224L, Infinity DC Power Plant H5692448 G630-4, Infinity DC Power Plant H5692448 G451C(2), Infinity DC Power Plant H5692448 G461(2), arises due to insufficient validation of input data. This vulnerability allows attackers to execute CSRF attacks.
The vulnerabilities of the software and hardware components of SCADA systems, such as ABB Pulsar Plus System Controller NE843S, Infinity DC Power Plant H5692448 G104, Infinity DC Power Plant H5692448 G842, Infinity DC Power Plant H5692448 G224L, Infinity DC Power Plant H5692448 G630-4, Infinity D...