Lucene search
+L

4118 matches found

Positive Technologies
Positive Technologies
•added 2023/10/16 12:00 a.m.•14 views

PT-2023-6570 · Unknown · Eisbaer Scada

Name of the Vulnerable Software and Affected Versions: EisBaer Scada affected versions not specified Description: The issue is related to the use of dangerous methods or functions in the SCADA system. Exploitation of this issue may allow a remote attacker to execute arbitrary code. The estimated...

9.8CVSS9.5AI score0.00711EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2023/10/16 12:00 a.m.•20 views

PT-2023-6567 · Unknown · Eisbaer Scada

Name of the Vulnerable Software and Affected Versions: EisBaer Scada affected versions not specified Description: The issue is related to the use of a hard-coded cryptographic key, which can allow an attacker to gain unauthorized access to protected information. Recommendations: At the moment,...

9.8CVSS9.3AI score0.00425EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2023/10/16 12:00 a.m.•21 views

PT-2023-6566 · Unknown · Eisbaer Scada

Name of the Vulnerable Software and Affected Versions: EisBaer Scada affected versions not specified Description: The issue is caused by improper authorization in the EisBaer Scada system. This can allow a remote attacker to execute arbitrary code due to weaknesses in the authorization procedure...

9.8CVSS9.4AI score0.00638EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
•added 2023/09/21 12:00 a.m.•15 views

The vulnerability of the InPlant SCADA system, related to insufficient calculation of password hashes, allows a intruder to gain unauthorized access to protected information.

The vulnerability of the InPlant SCADA system is related to insufficient calculation of password hashes during the loading of project files. Exploiting this vulnerability can allow an intruder to gain unauthorized access to protected information...

2.5CVSS5.3AI score0.00202EPSS
SaveExploits1References4Affected Software1
BDU FSTEC
BDU FSTEC
•added 2023/09/21 12:00 a.m.•15 views

The vulnerability of the InPlant SCADA system, related to deficiencies in authentication procedures, allows attackers to increase their privileges.

The vulnerability of the InPlant SCADA system is related to deficiencies in the authentication process when loading project files. Exploiting this vulnerability can allow attackers to enhance their privileges...

7.8CVSS6.6AI score0.00377EPSS
SaveExploits1References5Affected Software1
BDU FSTEC
BDU FSTEC
•added 2023/09/19 12:00 a.m.•19 views

The vulnerability of the client-server data processing and technological operations control application Proficy HMI/SCADA CIMPLICITY stems from issues with process management. This vulnerability allows attackers to escalate their privileges.

The vulnerability of the client-server data processing and technical operations control application Proficy HMI/SCADA CIMPLICITY exists due to a process management issue. Exploiting this vulnerability can allow attackers to increase their privileges within the system...

7.8CVSS7.1AI score0.00204EPSS
SaveExploits0References5Affected Software1
OSV
OSV
•added 2023/09/15 3:15 p.m.•17 views

CVE-2023-4986

A vulnerability classified as problematic was found in Supcon InPlant SCADA up to 20230901. Affected by this vulnerability is an unknown functionality of the file Project.xml. The manipulation leads to password hash with insufficient computational effort. Local access is required to approach this...

2.5CVSS4.4AI score0.00202EPSS
SaveExploits1References3
NVD
NVD
•added 2023/09/15 3:15 p.m.•41 views

CVE-2023-4986

A vulnerability classified as problematic was found in Supcon InPlant SCADA up to 20230901. Affected by this vulnerability is an unknown functionality of the file Project.xml. The manipulation leads to password hash with insufficient computational effort. Local access is required to approach this...

2.5CVSS3.7AI score0.00202EPSS
SaveExploits1References3
NVD
NVD
•added 2023/09/15 3:15 p.m.•34 views

CVE-2023-4985

A vulnerability classified as critical has been found in Supcon InPlant SCADA up to 20230901. Affected is an unknown function of the file Project.xml. The manipulation leads to improper authentication. An attack has to be approached locally. The exploit has been disclosed to the public and may be...

7.8CVSS6.5AI score0.00377EPSS
SaveExploits1References3
Prion
Prion
•added 2023/09/15 3:15 p.m.•31 views

Design/Logic Flaw

A vulnerability classified as problematic was found in Supcon InPlant SCADA up to 20230901. Affected by this vulnerability is an unknown functionality of the file Project.xml. The manipulation leads to password hash with insufficient computational effort. Local access is required to approach this...

1CVSS4AI score0.00202EPSS
SaveExploits1References3Affected Software1
Prion
Prion
•added 2023/09/15 3:15 p.m.•26 views

Authentication flaw

A vulnerability classified as critical has been found in Supcon InPlant SCADA up to 20230901. Affected is an unknown function of the file Project.xml. The manipulation leads to improper authentication. An attack has to be approached locally. The exploit has been disclosed to the public and may be...

4.6CVSS7.7AI score0.00377EPSS
SaveExploits1References3Affected Software1
Vulnrichment
Vulnrichment
•added 2023/09/15 2:31 p.m.•8 views

CVE-2023-4986 Supcon InPlant SCADA Project.xml unknown vulnerability

A vulnerability classified as problematic was found in Supcon InPlant SCADA up to 20230901. Affected by this vulnerability is an unknown functionality of the file Project.xml. The manipulation leads to password hash with insufficient computational effort. Local access is required to approach this...

2.5CVSS3.7AI score0.00202EPSS
SaveExploits1References3
Cvelist
Cvelist
•added 2023/09/15 2:31 p.m.•43 views

CVE-2023-4986 Supcon InPlant SCADA Project.xml unknown vulnerability

A vulnerability classified as problematic was found in Supcon InPlant SCADA up to 20230901. Affected by this vulnerability is an unknown functionality of the file Project.xml. The manipulation leads to password hash with insufficient computational effort. Local access is required to approach this...

2.5CVSS4.1AI score0.00202EPSS
SaveExploits1References3
CVE
CVE
•added 2023/09/15 2:31 p.m.•61 views

CVE-2023-4986

CVE-2023-4986 affects Supcon InPlant SCADA up to 20230901. The vulnerability stems from an unknown function in Project.xml that results in under-computed password hashes. Exploitation requires local access and has high attack complexity, with disclosure already public. Multiple sources (NVD, Red ...

2.5CVSS3.7AI score0.00202EPSS
SaveExploits1References3Affected Software1
Vulnrichment
Vulnrichment
•added 2023/09/15 2:00 p.m.•29 views

CVE-2023-4985 Supcon InPlant SCADA Project.xml improper authentication

A vulnerability classified as critical has been found in Supcon InPlant SCADA up to 20230901. Affected is an unknown function of the file Project.xml. The manipulation leads to improper authentication. An attack has to be approached locally. The exploit has been disclosed to the public and may be...

5.9CVSS6.8AI score0.00377EPSS
SaveExploits1References3
CVE
CVE
•added 2023/09/15 2:00 p.m.•74 views

CVE-2023-4985

CVE-2023-4985 affects Supcon InPlant SCADA up to 20230901. The issue stems from an unknown function in Project.xml that enables improper authentication. It requires local access to exploit, and public disclosure of exploits is noted. Several sources (NVD/Red Hat/CVE listings) corroborate the loca...

7.8CVSS6.5AI score0.00377EPSS
SaveExploits1References3Affected Software1
Cvelist
Cvelist
•added 2023/09/15 2:00 p.m.•48 views

CVE-2023-4985 Supcon InPlant SCADA Project.xml improper authentication

A vulnerability classified as critical has been found in Supcon InPlant SCADA up to 20230901. Affected is an unknown function of the file Project.xml. The manipulation leads to improper authentication. An attack has to be approached locally. The exploit has been disclosed to the public and may be...

5.9CVSS7.9AI score0.00377EPSS
SaveExploits1References3
CNVD
CNVD
•added 2023/09/15 12:00 a.m.•68 views

Siemens Spectrum Power 7 Local Elevation of Privilege Vulnerability

Spectrum Power 7 provides the essential components of SCADA, communications and data modeling for control and monitoring systems. Application suites can be added to optimize network and generation management in all areas of energy management. A local elevation of privilege vulnerability exists in...

8.2CVSS7.3AI score0.00159EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2023/09/15 12:00 a.m.•17 views

PT-2023-5276 · Supcon · Supcon Inplant Scada

Name of the Vulnerable Software and Affected Versions: Supcon InPlant SCADA up to 20230901 Description: A critical issue has been discovered related to improper authentication in the handling of project file loading. This could potentially allow an attacker to elevate their privileges. The issue ...

7.8CVSS7AI score0.00377EPSS
SaveExploits1References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/09/15 12:00 a.m.•5 views

CVE-2023-4985: Improper Authentication

A vulnerability classified as critical has been found in Supcon InPlant SCADA up to 20230901. Affected is an unknown function of the file Project.xml. The manipulation leads to improper authentication. An attack has to be approached locally. The exploit has been disclosed to the public and may be...

7.8CVSS5.8AI score0.00377EPSS
SaveExploits1References2
Rows per page