Lucene search
+L

3468 matches found

Positive Technologies
Positive Technologies
added 2023/02/24 12:0 a.m.9 views

PT-2023-5841 · Triangle Microworks · Triangle Microworks Scada Data Gateway

Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks SCADA Data Gateway affected versions not specified Description: This issue allows remote attackers to write arbitrary files on affected installations, potentially enabling them to execute code in the context of root. The...

6.2CVSS7.4AI score0.01246EPSS
SaveExploits0References8
CNNVD
CNNVD
added 2023/02/24 12:0 a.m.12 views

EcoStruxure Geo SCADA Expert 安全漏洞

EcoStruxure Geo SCADA Expert is an integrated, scalable, and reliable Supervisory Control and Data Acquisition SCADA software. A security vulnerability exists in EcoStruxure Geo SCADA Expert that stems from an improper output neutralization issue with the device's logs, which can lead to incorrec...

5.3CVSS5.7AI score0.00417EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2023/02/24 12:0 a.m.19 views

WordPress Plugin All in One SEO Pack 跨站脚本漏洞

WordPress and WordPress plugin are both products of the WordPress Foundation.WordPress is a blogging platform developed using the PHP language. The platform supports personal blog sites on servers running PHP and MySQL.WordPress plugin is an application plugin. A cross-site scripting vulnerabilit...

6.4CVSS6.3AI score0.02526EPSS
SaveExploits1References4
Vulnrichment
Vulnrichment
added 2023/02/24 12:0 a.m.9 views

CVE-2023-0595

A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...

5.3CVSS5.3AI score0.00417EPSS
SaveExploits0References1
CVE
CVE
added 2023/02/24 12:0 a.m.65 views

CVE-2023-0595

CVE-2023-0595 describes CWE-117: Improper Output Neutralization for Logs. Affects EcoStruxure Geo SCADA Expert (2019–2021, all versions prior to October 2022) and ClearSCADA (all versions prior to October 2022). The issue involves misinterpretation of log files caused by malicious packets sent to...

5.3CVSS5.3AI score0.00417EPSS
SaveExploits0References1Affected Software4
Cvelist
Cvelist
added 2023/02/24 12:0 a.m.49 views

CVE-2023-0595

A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port default 443. Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert...

5.3CVSS5.6AI score0.00417EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2023/02/12 12:0 a.m.11 views

PT-2023-3284 · Schneider Electric · Ecostruxure Geo Scada Expert +1

Name of the Vulnerable Software and Affected Versions: EcoStruxure Geo SCADA Expert versions 2019 through 2021 prior to October 2022 ClearSCADA versions prior to October 2022 Description: A vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to...

5.3CVSS5.2AI score0.00417EPSS
SaveExploits0References9
CNVD
CNVD
added 2023/02/06 12:0 a.m.56 views

Schneider Electric IGSS Data Server Integer Overflow Vulnerability

Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. An integer overflow vulnerability exists in Schneider Electric IGSS Data Server, which could be exploited by an attacker to submit special requests that could crash the...

9.5AI score0.02141EPSS
SaveExploits0Affected Software1
NVD
NVD
added 2023/01/31 5:15 p.m.25 views

CVE-2023-22610

A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port...

9.1CVSS9.2AI score0.0057EPSS
SaveExploits0References1
NVD
NVD
added 2023/01/31 5:15 p.m.21 views

CVE-2023-22611

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...

7.5CVSS7.2AI score0.00569EPSS
SaveExploits0References1
OSV
OSV
added 2023/01/31 5:15 p.m.11 views

CVE-2023-22611

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...

7.5CVSS5.8AI score0.00569EPSS
SaveExploits0References1
Prion
Prion
added 2023/01/31 5:15 p.m.19 views

Authorization

A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port...

5CVSS7.5AI score0.0057EPSS
SaveExploits0References1Affected Software3
Prion
Prion
added 2023/01/31 5:15 p.m.25 views

Information disclosure

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...

5CVSS7.2AI score0.00569EPSS
SaveExploits0References1Affected Software3
CVE
CVE
added 2023/01/31 12:0 a.m.62 views

CVE-2023-22610

CVE-2023-22610 affects Schneider Electric EcoStruxure Geo SCADA Expert (Geo SCADA server) with an Incorrect Authorization (CWE-863) flaw that could cause Denial of Service when specific messages are sent over the database server TCP port. Public details in connected sources indicate vulnerable Ec...

9.1CVSS7.4AI score0.0057EPSS
SaveExploits0References1Affected Software3
Cvelist
Cvelist
added 2023/01/31 12:0 a.m.36 views

CVE-2023-22611

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...

7.5CVSS7.4AI score0.00569EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2023/01/31 12:0 a.m.12 views

CVE-2023-22610

A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port...

9.1CVSS9.2AI score0.0057EPSS
SaveExploits0References1
CVE
CVE
added 2023/01/31 12:0 a.m.74 views

CVE-2023-22611

CVE-2023-22611 describes an information disclosure vulnerability (CWE-200) in EcoStruxure Geo SCADA Expert 2019–2021 (formerly ClearSCADA) where sensitive data could be exposed via specific messages sent to the database server TCP port. The CVSSv3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N) yi...

7.5CVSS7.2AI score0.00569EPSS
SaveExploits0References1Affected Software3
Vulnrichment
Vulnrichment
added 2023/01/31 12:0 a.m.10 views

CVE-2023-22611

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 formerly known as...

7.5CVSS7.2AI score0.00569EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2023/01/31 12:0 a.m.12 views

EcoStruxure Geo SCADA Expert 信息泄露漏洞

EcoStruxure Geo SCADA Expert is an integrated, scalable, and reliable monitoring and data acquisition SCADA software. An information disclosure vulnerability exists in EcoStruxure Geo SCADA Expert version 2019, version 2020, October 2021 to 2022, ClearSCADA that originates from exposing sensitive...

7.5CVSS7.3AI score0.00569EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2023/01/31 12:0 a.m.41 views

CVE-2023-22610

A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port...

9.1CVSS9.3AI score0.0057EPSS
SaveExploits0References1
Rows per page
Query Builder