368 matches found
Schneider Electric IGSS
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: IGSS Interactive Graphical SCADA System Vulnerabilities: Missing Authentication for Critical Function, Insufficient Verification of Data Authenticity, Deserialization of...
Schneider Electric IGSS Data Server Access Control Error Vulnerability
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. An access control error vulnerability exists in Schneider Electric IGSS Data Server, which stems from a lack of authentication of key functional identities and could be...
Custom Reports Component Code Execution
The vulnerability of the Custom Reports component of the SCADA system’s data server and the Custom Reports and IGSS Dashboard monitoring tools exists due to insufficient verification of input data. Exploiting this vulnerability could allow a perpetrator to execute arbitrary code using a specially...
Schneider Electric IGSS Data Server Data Forgery Issue Vulnerability (CNVD-2023-29371)
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. Schneider Electric IGSS Data Server is vulnerable to a data forgery issue, which could be exploited by an attacker to gain access to delete files in the IGSS project...
Schneider Electric IGSS Data Server Input Validation Error Vulnerability
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. Schneider Electric IGSS Data Server is vulnerable to an input validation error, which could be exploited by an attacker to cause remote code execution...
Schneider Electric IGSS Data Server Data Forgery Issue Vulnerability (CNVD-2023-29373)
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. Schneider Electric IGSS Data Server is vulnerable to a data forgery issue, which could be exploited by an attacker to send specific crafted messages to the data server T...
Schneider Electric IGSS Data Server Access Control Error Vulnerability (CNVD-2023-29375)
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. An access control error vulnerability exists in Schneider Electric IGSS Data Server, which could be exploited by an attacker to create malicious report files in the IGSS...
Schneider Electric IGSS Data Server Data Forgery Issue Vulnerability
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. Schneider Electric IGSS Data Server is vulnerable to a data forgery issue, which can be exploited by an attacker to cause a denial of service by sending a specific craft...
PT-2023-7551 · Unknown · Trace Mode
Name of the Vulnerable Software and Affected Versions: TRACE MODE affected versions not specified Description: The issue is related to the unencrypted storage of credentials in the SCADA system. Exploitation of this issue could allow an attacker to modify user privileges, potentially granting...
Schneider Electric IGSS Data Server Integer Overflow Vulnerability
Schneider Electric IGSS Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. An integer overflow vulnerability exists in Schneider Electric IGSS Data Server, which could be exploited by an attacker to submit special requests that could crash the...
Securing IoT devices against attacks that target critical infrastructure
South Staffordshire PLC, a company that supplies water to over one million customers in the United Kingdom, notified its customers in August of being a target of a criminal cyberattack. This incident highlights the sophisticated threats that critical industries face today. According to South...
Securing IoT devices against attacks that target critical infrastructure
South Staffordshire PLC, a company that supplies water to over one million customers in the United Kingdom, notified its customers in August of being a target of a criminal cyberattack. This incident highlights the sophisticated threats that critical industries face today. According to South...
PT-2022-5035 · Hitachi Energy · Hitachi Energy Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: Hitachi Energy MicroSCADA X SYS600 versions 10.2 through 10.3.1 Description: The issue is related to an Improper Input Validation vulnerability in the ICCP stack of Hitachi Energy MicroSCADA X SYS600. This vulnerability can cause a...
Distributed Data Systems WebHmi operating system command injection vulnerability
Distributed Data Systems WebHmi is a Scada system with a built-in web server from Distributed Data Systems, Ukraine. It is used to monitor and control any automation system on a local network and over the Internet from computers and mobile devices. An operating system command injection...
Data Server Code Execution
The vulnerability of the Data Server database in the Interactive Graphical SCADA System IGSS involves copying buffers without checking the size of the input data. Exploiting this vulnerability allows a malicious actor to execute arbitrary code by sending specially crafted messages...
Schneider Electric IGSS Data Server Buffer Overflow Vulnerability
Schneider Electric IGSS Data Server is a data server for the Interactive Graphics Scada system from Schneider Electric France. prior to Schneider Electric IGSS Data Server version 15.0.0.22074 A buffer overflow vulnerability exists, which stems from the presence of a boundary error in the...
Schneider Electric IGSS Data Server alarm data buffer overflow vulnerability
The Schneider Electric Igss Data Server is a data server for the interactive graphical Scada system from Schneider Electric France. A buffer overflow vulnerability exists in Schneider Electric IGSS Data Server versions prior to 15.0.0.22140, which stems from a boundary error when processing...
A binary vulnerability exists in IGSS (Interactive Graphical SCADA System)
IGSS Interactive Graphical SCADA System is an industrial control SCADA system from Schneider, which is used in various fields such as power, wastewater treatment, manufacturing, etc. A binary vulnerability exists in IGSS Interactive Graphical SCADA System, which can be exploited by attackers to...
Schneider Electric Interactive Graphical Scada System Integer Overflow Vulnerability
The Schneider Electric Interactive Graphical Scada System Igss is a Scada system for monitoring and controlling industrial processes from Schneider Electric, France. The Schneider Electric Interactive Graphical Scada System has an integer overflow vulnerability that can be exploited by an attacke...
Schneider Electric Interactive Graphical SCADA System Initialization Error Vulnerability
Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An initialization error vulnerability exists in the Schneider Electric Interactive Graphical...