51 matches found
CVE-2023-1437
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute...
CVE-2021-32954
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system...
CVE-2021-32956
Advantech WebAccess/SCADA Versions 9.0.1 and prior is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage...
CVE-2020-25161
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2012-4355
TCPIPSStory.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted negative integer after the opcode, triggering incorrect function-pointer processing that can lead to ...
CVE-2012-4353
Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorrect file-open attempt by the TCPIPSBinOpenFileFP function,...
CVE-2011-4053
Untrusted search path vulnerability in 7-Technologies 7T Interactive Graphical SCADA System IGSS before 9.0.0.11291 allows local users to gain privileges via a Trojan horse DLL in the current working directory...
CVE-2012-4359
Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service invalid 0x00 write operation and daemon crash or possibly have unspecified other impact via a...
The vulnerability of the Rapid SCADA system, related to incorrect restrictions on the name of the path to the restricted access catalog, allows a intruder to execute arbitrary code.
The vulnerability of the SCADA system Rapid SCADA is related to incorrect restrictions on the path name to the restricted access catalog when extracting files from archives. Exploiting this vulnerability allows a malicious actor to execute arbitrary code by sending a specially crafted HTTP reques...
Rapid Software Rapid SCADA Security Vulnerability
Rapid Software Rapid SCADA is an open source industrial automation platform from Rapid Software. A security vulnerability exists in Rapid Software Rapid SCADA 5.8.4 and earlier versions that stems from a misconfiguration of permissions, which allows any authenticated user on the server to write...
Rapid Software Rapid SCADA Security Vulnerability
Rapid Software Rapid SCADA is an open source industrial automation platform from Rapid Software. A security vulnerability exists in Rapid Software Rapid SCADA version 5.8.4 and prior versions, which stems from a vulnerability that allows an attacker to generate an error message containing sensiti...
PT-2023-6566 · Unknown · Eisbaer Scada
Name of the Vulnerable Software and Affected Versions: EisBaer Scada affected versions not specified Description: The issue is caused by improper authorization in the EisBaer Scada system. This can allow a remote attacker to execute arbitrary code due to weaknesses in the authorization procedure...
CVE-2023-4485 ARDEREG Sistemas SCADA SQL Injection
ARDEREG Sistema SCADA Central versions 2.203 and prior login page are vulnerable to an unauthenticated blind SQL injection attack. An attacker could manipulate the application's SQL query logic to extract sensitive information or perform unauthorized actions within the database. In this case, th...
The vulnerability of the Advantech WebAccss/SCADA SCADA system, related to the unlimited loading of dangerous type files, allows a intruder to execute arbitrary code.
The vulnerability of the Advantech WebAccss/SCADA SCADA system is related to the unlimited loading of dangerous files. Exploiting this vulnerability allows a malicious actor to execute arbitrary code remotely...
Advantech WebAccess/SCADA 数据伪造问题漏洞
Advantech WebAccess/SCADA is a set of SCADA software based on browser architecture from Advantech, China. The software supports dynamic graphical display and real-time data control, and provides remote control and management of automation devices. A security vulnerability exists in Advantech...
CVE-2023-28384
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands...
CVE-2021-33001 xArrow SCADA Cross-site Scripting
xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘bdate’ of the resource xhisvalue.htm, which may allow an unauthorized attacker to execute arbitrary code...
CVE-2021-41579
LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. If an attacker can get a victim to load a malicious els project file and use the play feature, then the attacker can bypass a consent popup and write arbitrary files to OS locations where the user has...
GE Digital HMI/SCADA iFIX Permission License and Access Control Issues Vulnerability
Genesys PureEngage Digital is an omni-channel customer interaction management platform from Genesys. The platform supports features such as online chat, email and SMS Short Message Service. A security vulnerability exists in GE Digital HMI/SCADA iFIX that originates from allowing a locally...