Lucene search
+L

70 matches found

Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•22 views

Siemens SCALANCE S615 6GK5615-0AA00-2AA2 LAN router

Binary data 764596.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•28 views

Siemens Multiple Devices Profinet DCP Denial of Service

Binary data 720110.prm...

7.1CVSS7AI score0.01149EPSS
SaveExploits0References2
ICS
ICS
•added 2017/11/17 12:00 a.m.•248 views

Siemens SCALANCE W1750D, M800, S615, and RUGGEDCOM RM1224 (Update C)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low skill level to exploit. Vendor: Siemens --------- Begin Update C Part 1 of 3 -------- Equipment: SCALANCE W1750D, M800, S615, and RUGGEDCOM RM1224 --------- End Update C Part 1 of 3 -------- Vulnerabilities: Resource...

9.8CVSS9.9AI score0.84925EPSS
SaveExploits16References9
OSV
OSV
•added 2016/09/29 10:59 a.m.•16 views

CVE-2016-7090

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session...

4CVSS5.8AI score0.01895EPSS
SaveExploits0References3
NVD
NVD
•added 2016/09/29 10:59 a.m.•32 views

CVE-2016-7090

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session...

4.3CVSS4.2AI score0.01895EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2016/09/29 10:00 a.m.•42 views

CVE-2016-7090

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session...

4.2AI score0.01895EPSS
SaveExploits0References3
CVE
CVE
•added 2016/09/29 10:00 a.m.•74 views

CVE-2016-7090

CVE-2016-7090 affects Siemens SCALANCE M-800 and S615 modules with firmware before 4.02. The integrated web server fails to set the Secure attribute on the session cookie in HTTPS, enabling cookie capture if the cookie is transmitted in an insecure (HTTP) context. Affected products: SCALANCE M-80...

4.3CVSS4.3AI score0.01895EPSS
SaveExploits0References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/09/29 12:00 a.m.•5 views

CVE-2016-7090: Exposure of Sensitive Information to an Unauthorized Actor

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session...

4.3CVSS5.6AI score0.01895EPSS
SaveExploits0References2
ICS
ICS
•added 2016/07/01 6:00 a.m.•66 views

Siemens SCALANCE M-800/S615 Web Vulnerability

OVERVIEW Siemens has identified a web security vulnerability in Siemen’s SCALANCE M-800 and S615 modules. This vulnerability was reported directly to Siemens by Alexander Van Maele and Tijl Deneut from HOWEST. Siemens has produced a new firmware version to mitigate this vulnerability. AFFECTED...

4.3CVSS4.3AI score0.01895EPSS
SaveExploits0References10
ICS
ICS
•added 2016/04/12 12:00 a.m.•83 views

Siemens Industrial Products glibc Library Vulnerability (Update C)

OVERVIEW This updated advisory is a follow-up to the advisory update titled ICSA-16-103-01B Siemens Industrial Products glibc Library Vulnerability that was published July 14, 2016, on the NCCIC/ICS-CERT web site. Siemens reports that a buffer overflow vulnerability in the glibc library could...

8.1CVSS8AI score0.90987EPSS
SaveExploits17References26