Lucene search
+L

29 matches found

ICS
ICS
•added 2019/09/10 12:00 a.m.•558 views

ICSA-19-253-03_Siemens Industrial Products (Update P)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Products Vulnerabilities: Excessive Data Query Operations in a Large Data Table, Integer Overflow or Wraparound, Uncontrolled Resource Consumption 2. UPDATE INFORMATION...

8.6AI score
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•12 views

Siemens SCALANCE S602 Security module

Binary data 751132.prm...

7.3AI score
SaveExploits0
OSV
OSV
•added 2018/12/13 4:29 p.m.•15 views

CVE-2018-16555

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.4CVSS5.7AI score0.00689EPSS
SaveExploits0References2
CVE
CVE
•added 2018/12/13 4:00 p.m.•74 views

CVE-2018-16555

CVE-2018-16555 affects Siemens SCALANCE S602, S612, S623 and S627-2M (all versions before 4.0.1.1). The vulnerability is an improper neutralization of input during web page generation, enabling cross-site scripting (XSS) if a user, who must be logged into the web interface, is tricked into clicki...

5.4CVSS5.1AI score0.00689EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2018/12/13 4:00 p.m.•35 views

CVE-2018-16555

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.1AI score0.00689EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/12/13 12:00 a.m.•6 views

CVE-2018-16555: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)

A vulnerability has been identified in SCALANCE S602 All versions V4.0.1.1, SCALANCE S612 All versions V4.0.1.1, SCALANCE S623 All versions V4.0.1.1, SCALANCE S627-2M All versions V4.0.1.1. The integrated web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked in...

5.4CVSS5.6AI score0.00689EPSS
SaveExploits0References3
CNVD
CNVD
•added 2018/11/16 12:00 a.m.•15 views

Multiple Siemens Products Cross-Site Scripting Vulnerabilities

Siemens SCALANCE S602 and others are Ethernet security modules from Siemens, Germany. A cross-site scripting vulnerability exists in several Siemens products, which can be exploited by remote attackers to inject arbitrary scripts via malicious links...

5.4CVSS5.3AI score0.00689EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2018/11/13 12:00 a.m.•3 views

PT-2018-2164

Name of the Vulnerable Software and Affected Versions SCALANCE S602 versions prior to 4.0.1.1 SCALANCE S612 versions prior to 4.0.1.1 SCALANCE S623 versions prior to 4.0.1.1 SCALANCE S627-2M versions prior to 4.0.1.1 Description A vulnerability has been identified that could allow Cross-Site...

5.4CVSS0.00689EPSS
SaveExploits0References6
Prion
Prion
•added 2012/04/18 10:33 a.m.•29 views

Stack overflow

Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service device outage or possibly execute arbitrary code via a crafted...

6.1CVSS9AI score0.01598EPSS
SaveExploits0References4Affected Software4