CVE-2022-2179: Improper Restriction of Rendered UI Layers or Frames

The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks...

6.5CVSS6.7AI score0.01199EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2022/07/07 12:00 a.m.•1 views

PT-2022-4950

Name of the Vulnerable Software and Affected Versions Rockwell Automation MicroLogix 1100/1400 versions 21.007 and prior Description The issue is related to the X-Frame-Options header not being configured in the HTTP response, which could allow clickjacking attacks. This could enable a remote...

6.8CVSS0.01199EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2021/07/09 2:03 p.m.•50 views

CVE-2021-33012

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

8.8AI score0.02637EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/07/09 12:00 a.m.•2 views

CVE-2021-33012: Improper Input Validation

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will...

8.6CVSS5.9AI score0.02637EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/03/16 12:00 a.m.•4 views

CVE-2020-6984: Use of a Broken or Risky Cryptographic Algorithm

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable...

9.8CVSS7.5AI score0.02847EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/09/20 12:00 a.m.•4 views

CVE-2017-7924: Improper Input Validation

An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands PCCC packet to the...

7.5CVSS7.2AI score0.22182EPSS