Lucene search
+L

12579 matches found

Microsoft Security Update
Microsoft Security Update
added 2020/10/13 5:00 p.m.15 views

2020-10 Cumulative Update for Windows Server 2016 for x64-based Systems (KB4580346)

A security issue has been identified in a Microsoft software product that could affect your system. You can help protect your system by installing this update from Microsoft. For a complete listing of the issues that are included in this update, see the associated Microsoft Knowledge Base article...

1.5AI score
SaveExploits0
Microsoft Security Update
Microsoft Security Update
added 2020/10/13 5:00 p.m.11 views

2020-10 Dynamic Cumulative Update for Windows 10 Version 2004 for x86-based Systems (KB4579311)

ComponentUpdate: A security issue has been identified in a Microsoft software product that could affect your system. You can help protect your system by installing this update from Microsoft. For a complete listing of the issues that are included in this update, see the associated Microsoft...

6.7AI score
SaveExploits0
Microsoft Security Update
Microsoft Security Update
added 2020/10/13 5:00 p.m.12 views

2020-10 Cumulative Update for Windows 10 Version 1903 for ARM64-based Systems (KB4577671)

Install this update to resolve issues in Windows. For a complete listing of the issues that are included in this update, see the associated Microsoft Knowledge Base article for more information. After you install this item, you may have to restart your computer...

6.7AI score
SaveExploits0
Microsoft Security Update
Microsoft Security Update
added 2020/10/13 5:00 p.m.12 views

2020-10 Cumulative Update for Windows 10 Version 1703 for x64-based Systems (KB4580370)

A security issue has been identified in a Microsoft software product that could affect your system. You can help protect your system by installing this update from Microsoft. For a complete listing of the issues that are included in this update, see the associated Microsoft Knowledge Base article...

2.7AI score
SaveExploits0
Microsoft Security Update
Microsoft Security Update
added 2020/10/13 5:00 p.m.15 views

2020-10 Cumulative Update for Windows Server, version 1903 for ARM64-based Systems (KB4577671)

Install this update to resolve issues in Windows. For a complete listing of the issues that are included in this update, see the associated Microsoft Knowledge Base article for more information. After you install this item, you may have to restart your computer...

6.7AI score
SaveExploits0
Microsoft Security Update
Microsoft Security Update
added 2020/10/13 5:00 p.m.14 views

2020-10 Cumulative Update for Windows 10 Version 1909 for x86-based Systems (KB4577671)

Install this update to resolve issues in Windows. For a complete listing of the issues that are included in this update, see the associated Microsoft Knowledge Base article for more information. After you install this item, you may have to restart your computer...

6.7AI score
SaveExploits0
Microsoft Security Update
Microsoft Security Update
added 2020/10/13 5:00 p.m.10 views

2020-10 Cumulative Update for Windows 10 Version 1803 for ARM64-based Systems (KB4580330)

A security issue has been identified in a Microsoft software product that could affect your system. You can help protect your system by installing this update from Microsoft. For a complete listing of the issues that are included in this update, see the associated Microsoft Knowledge Base article...

6.7AI score
SaveExploits0
Arista
Arista
added 2020/10/07 12:00 a.m.42 views

Security Advisory 0053

Security Advisory 0053 PDF Date: October 7th, 2020 Version: 1.0 Revision | Date | Changes ---|---|--- 1.0 | October 7th, 2020 | Initial Release The CVE-ID tracking this issue is: CVE-2020-17355 CVSSv3 Base Score: 7.5/10 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Description This advisory...

7.5CVSS7.4AI score0.01209EPSS
SaveExploits0Affected Software1
Prion
Prion
added 2020/09/25 4:23 a.m.18 views

Design/Logic Flaw

The Telnet service of Rubetek RV-3406, RV-3409, and RV-3411 cameras firmware versions v342, v339 can allow a remote attacker to gain access to RTSP and ONFIV services without authentication. Thus, the attacker can watch live streams from the camera, rotate the camera, change some settings...

9CVSS9.2AI score0.01848EPSS
SaveExploits0References1Affected Software3
Tenable Nessus
Tenable Nessus
added 2020/09/25 12:00 a.m.28 views

Cisco IOS XR Authenticated User Privilege Escalation (cisco-sa-iosxr-cli-privescl-sDVEmhqv)

According to its self-reported version, Cisco IOS XR Software is affected by a privilege escalation vulnerability in task group assignment for a specific CLI command due to incorrect mapping of task groups assignments. An authenticated, local attacker with read permissions could exploit this...

8.4CVSS7.6AI score0.00281EPSS
SaveExploits0References5
NVD
NVD
added 2020/09/24 6:15 p.m.23 views

CVE-2020-3403

A vulnerability in the CLI of Cisco IOS XE Software could allow an authenticated, local attacker to inject a command to the underlying operating system that will execute with root privileges upon the next reboot of the device. The authenticated user must have privileged EXEC permissions on the...

7.8CVSS0.00376EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2020/09/14 12:00 a.m.37 views

Juniper Junos DNS filtering JSA11028

According to the self reported version of Junos OS on the remote device is vulnerable to improper input validation. When DNS filtering is enabled on Juniper Networks Junos MX Series with one of the following cards MS-PIC, MS-MIC or MS-MPC, an incoming stream of packets processed by the...

8.3CVSS7.7AI score0.00627EPSS
SaveExploits0References2
Microsoft Security Update
Microsoft Security Update
added 2020/09/11 5:00 p.m.12 views

2020-09 Cumulative Update for Windows Server, version 20H2 for x64-based Systems (KB4571756)

Install this update to resolve issues in Windows. For a complete listing of the issues that are included in this update, see the associated Microsoft Knowledge Base article for more information. After you install this item, you may have to restart your computer...

6.7AI score
SaveExploits0
OSV
OSV
added 2020/09/11 2:15 p.m.9 views

CVE-2020-16216

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and...

6.5CVSS6.6AI score0.00698EPSS
SaveExploits0References2
OSV
OSV
added 2020/09/11 2:15 p.m.12 views

CVE-2020-16224

In Patient Information Center iX PICiX Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to...

6.5CVSS6.6AI score0.00594EPSS
SaveExploits0References2
NVD
NVD
added 2020/09/11 2:15 p.m.31 views

CVE-2020-16224

In Patient Information Center iX PICiX Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to...

6.5CVSS0.00594EPSS
SaveExploits0References2
Prion
Prion
added 2020/09/11 2:15 p.m.17 views

Code injection

In Patient Information Center iX PICiX Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to...

3.3CVSS6.9AI score0.00594EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2020/09/11 1:05 p.m.55 views

CVE-2020-16224

CVE-2020-16224 affects Philips PICiX (Patient Information Center iX) in versions C.02 and C.03. The vulnerability stems from improper handling of a length field in a formatted message or structure, where the length value is inconsistent with the actual data length, causing the surveillance statio...

6.5CVSS6.5AI score0.00594EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
added 2020/09/11 12:00 a.m.16 views

PT-2020-14815 · Philips · Intellivue Mx750 +9

Name of the Vulnerable Software and Affected Versions: IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior Description: The product receives input or data but does not validate or incorrectly validates that the...

6.5CVSS6.4AI score0.00698EPSS
SaveExploits0References4
OSV
OSV
added 2020/09/09 7:15 p.m.11 views

CVE-2020-10050

A vulnerability has been identified in SIMATIC RTLS Locating Manager All versions V2.10.2. The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts...

7.8CVSS7.2AI score0.00286EPSS
SaveExploits0References1
Rows per page
Query Builder