Lucene search
+L

12761 matches found

Vulnrichment
Vulnrichment
•added 2024/03/27 12:00 a.m.•19 views

CVE-2024-25736

An issue was discovered on WyreStorm Apollo VX20 devices before 1.3.58. Remote attackers can restart the device via a /device/reboot GET request...

7AI score0.04343EPSS
SaveExploits4References2
CNVD
CNVD
•added 2024/03/27 12:00 a.m.•51 views

Rockwell Automation PowerFlex 527 Input Validation Error Vulnerability

The Rockwell Automation PowerFlex 527 is an adjustable AC frequency converter from Rockwell Automation. The Rockwell Automation PowerFlex 527 has an input validation error vulnerability that can be exploited by an attacker to cause CIP communication to be interrupted, requiring a manual restart...

7.5CVSS7.4AI score0.0282EPSS
SaveExploits0References1
CVE
CVE
•added 2024/03/27 12:00 a.m.•71 views

CVE-2024-25736

The WyreStorm Apollo VX20 video conferencing device (versions prior to 1.3.58 ) is vulnerable to a Denial of Service (DoS) attack due to Incorrect Access Control . A remote attacker can trigger a device restart by sending an unauthenticated HTTP GET request to the /device/reboot endpoint via the ...

6.9AI score0.04343EPSS
SaveExploits4References3Affected Software1
UbuntuCve
UbuntuCve
•added 2024/03/26 3:15 p.m.•41 views

CVE-2024-23722

In Fluent Bit 2.1.8 through 2.2.1, a NULL pointer dereference can be caused via an invalid HTTP payload with the content type of x-www-form-urlencoded. It crashes and does not restart. This could result in logs not being delivered properly...

7.5CVSS7.1AI score0.00944EPSS
SaveExploits2References4
Vulnrichment
Vulnrichment
•added 2024/03/26 12:00 a.m.•19 views

CVE-2024-23722

In Fluent Bit 2.1.8 through 2.2.1, a NULL pointer dereference can be caused via an invalid HTTP payload with the content type of x-www-form-urlencoded. It crashes and does not restart. This could result in logs not being delivered properly...

7.1AI score0.00944EPSS
SaveExploits2References2
NVD
NVD
•added 2024/03/25 10:37 p.m.•48 views

CVE-2024-21914

A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product...

5.3CVSS5.3AI score0.00658EPSS
SaveExploits0References1
OSV
OSV
•added 2024/03/25 10:37 p.m.•12 views

CVE-2024-21914

A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product...

5.3CVSS5.8AI score0.00658EPSS
SaveExploits0References1
CVE
CVE
•added 2024/03/25 9:27 p.m.•115 views

CVE-2024-21914

Rockwell Automation CVE-2024-21914 affects FactoryTalk View ME (PanelView Plus 7 boot terminal) prior to v14. Root cause: Improper neutralization of input during web page generation (Cross-site Scripting). Impact: remote restart of PanelView Plus 7 with loss of view/control; low availability impa...

5.3CVSS5.8AI score0.00658EPSS
SaveExploits0References1Affected Software1
OSV
OSV
•added 2024/03/25 9:15 p.m.•18 views

CVE-2024-2427

A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover...

7.5CVSS5.8AI score0.00687EPSS
SaveExploits0References1
NVD
NVD
•added 2024/03/25 9:15 p.m.•25 views

CVE-2024-2427

A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover...

7.5CVSS7.5AI score0.00687EPSS
SaveExploits0References1
NVD
NVD
•added 2024/03/25 9:15 p.m.•28 views

CVE-2024-2425

A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it...

7.5CVSS7.5AI score0.0282EPSS
SaveExploits0References1
OSV
OSV
•added 2024/03/25 9:15 p.m.•12 views

CVE-2024-2426

A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it...

7.5CVSS5.8AI score0.0282EPSS
SaveExploits0References1
NVD
NVD
•added 2024/03/25 9:15 p.m.•33 views

CVE-2024-2426

A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it...

7.5CVSS7.5AI score0.0282EPSS
SaveExploits0References1
CVE
CVE
•added 2024/03/25 8:20 p.m.•99 views

CVE-2024-2427

CVE-2024-2427 pertains to the Rockwell Automation PowerFlex 527, a configurable AC drive. The reported issue is a denial-of-service caused by improper traffic throttling: if multiple data packets are sent to the device, it can crash and require a manual restart. Connected documents provide concre...

7.5CVSS7.5AI score0.00687EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2024/03/25 8:17 p.m.•70 views

CVE-2024-2426

The CVE-2024-2426 entry concerns Rockwell Automation PowerFlex 527, affecting versions v2.001.x and later. The vulnerability is an improper input validation in the device that can cause a denial-of-service by disrupting CIP communication, potentially requiring a manual restart to recover. The iss...

7.5CVSS7.5AI score0.0282EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2024/03/25 8:14 p.m.•71 views

CVE-2024-2425

Summary (CVE-2024-2425) Rockwell Automation PowerFlex 527 is affected by a denial-of-service vulnerability due to improper input validation (CWE-120). Affected product: PowerFlex 527, versions v2.001.x and later. Impact: remote DoS causing the web server to crash and require a manual restart; hig...

7.5CVSS7.5AI score0.0282EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
•added 2024/03/25 12:00 a.m.•10 views

Rockwell Automation PowerFlex 安全漏洞

The Rockwell Automation PowerFlex 527 is an adjustable AC frequency converter from Rockwell Automation. The Rockwell Automation PowerFlex 527 has an input validation error vulnerability that can be exploited by an attacker to cause CIP communication to be interrupted, requiring a manual restart...

7.5CVSS6.8AI score0.0282EPSS
SaveExploits0References2
Microsoft KB
Microsoft KB
•added 2024/03/22 7:00 a.m.•123 views

January 9, 2024-KB5033920 Cumulative Update for .NET Framework 3.5 and 4.8.1 for Windows 11, version 22H2 and Windows 11, version 23H2

None None...

9.8CVSS6.8AI score0.98624EPSS
SaveExploits1
Positive Technologies
Positive Technologies
•added 2024/03/21 12:00 a.m.•30 views

PT-2024-2553 · Rockwell Automation · Rockwell Automation Panelview Plus 7 +1

Name of the Vulnerable Software and Affected Versions: Rockwell Automation PanelView Plus 7 affected versions not specified Rockwell Automation FactoryTalk View Machine Edition affected versions not specified Description: A vulnerability exists in the affected product that allows a malicious user...

5.3CVSS7AI score0.00658EPSS
SaveExploits0References10
Positive Technologies
Positive Technologies
•added 2024/03/21 12:00 a.m.•11 views

PT-2024-8229 · Podman · Podman

Name of the Vulnerable Software and Affected Versions: Podman affected versions not specified Description: A flaw in Podman may allow an attacker to create a specially crafted container that can exhaust resources in /dev/shm by creating a large number of IPC resources. This can lead to a...

8.7CVSS9.2AI score0.00545EPSS
SaveExploits0References21
Rows per page