12472 matches found
OESA-2024-1353 kernel security update
The Linux Kernel, the operating system core itself. Security Fixes: In the Linux kernel, the following vulnerability has been resolved: KVM: x86/mmu: Don't advance iterator after restart due to yielding After dropping mmulock in the TDP MMU, restart the iterator during tdpiternext and do not...
In Fluent Bit 2.1.8 through 2.2.1 a NULL pointer dereference can be caused via an invalid HTTP payload with the content type of x-www-form-urlencoded. It crashes and does not restart. This could result in logs not being delivered properly.
...
CVE-2024-3019
A flaw was found in PCP. The default pmproxy configuration exposes the Redis server backend to the local network, allowing remote command execution with the privileges of the Redis user. This issue can only be exploited when pmproxy is running. By default, pmproxy is not running and needs to be...
CVE-2024-25736
An issue was discovered on WyreStorm Apollo VX20 devices before 1.3.58. Remote attackers can restart the device via a /device/reboot GET request...
CVE-2024-25736
The CVE-2024-25736 entry affects WyreStorm Apollo VX20 devices prior to firmware version 1.3.58. The vulnerability allows remote attackers to restart the device by issuing a GET request to /device/reboot (Web interface/reboot and reset commands). Exploitation details in the sources describe an In...
CVE-2024-25736
An issue was discovered on WyreStorm Apollo VX20 devices before 1.3.58. Remote attackers can restart the device via a /device/reboot GET request...
Rockwell Automation PowerFlex 527 Input Validation Error Vulnerability
The Rockwell Automation PowerFlex 527 is an adjustable AC frequency converter from Rockwell Automation. The Rockwell Automation PowerFlex 527 has an input validation error vulnerability that can be exploited by an attacker to cause CIP communication to be interrupted, requiring a manual restart...
CVE-2024-25736
An issue was discovered on WyreStorm Apollo VX20 devices before 1.3.58. Remote attackers can restart the device via a /device/reboot GET request...
CVE-2024-23722
In Fluent Bit 2.1.8 through 2.2.1, a NULL pointer dereference can be caused via an invalid HTTP payload with the content type of x-www-form-urlencoded. It crashes and does not restart. This could result in logs not being delivered properly...
CVE-2024-23722
In Fluent Bit 2.1.8 through 2.2.1, a NULL pointer dereference can be caused via an invalid HTTP payload with the content type of x-www-form-urlencoded. It crashes and does not restart. This could result in logs not being delivered properly...
CVE-2024-21914
A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product...
CVE-2024-21914
A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product...
CVE-2024-21914
Rockwell Automation CVE-2024-21914 affects FactoryTalk View ME (PanelView Plus 7 boot terminal) prior to v14. Root cause: Improper neutralization of input during web page generation (Cross-site Scripting). Impact: remote restart of PanelView Plus 7 with loss of view/control; low availability impa...
CVE-2024-2426
A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it...
CVE-2024-2427
A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover...
CVE-2024-2426
A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it...
CVE-2024-2427
A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover...
CVE-2024-2425
A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it...
CVE-2024-2427
CVE-2024-2427 pertains to the Rockwell Automation PowerFlex 527, a configurable AC drive. The reported issue is a denial-of-service caused by improper traffic throttling: if multiple data packets are sent to the device, it can crash and require a manual restart. Connected documents provide concre...
CVE-2024-2426
The CVE-2024-2426 entry concerns Rockwell Automation PowerFlex 527, affecting versions v2.001.x and later. The vulnerability is an improper input validation in the device that can cause a denial-of-service by disrupting CIP communication, potentially requiring a manual restart to recover. The iss...