168 matches found
Threat landscape for industrial automation systems in H1 2021
The H1 2021 ICS threat report at a glance Percentage of ICS computers attacked 1. During the first half of 2021 H1 2021, the percentage of attacked ICS computers was 8%, which was 0.4 percentage points p.p. higher than that for H2 2020. Percentage of ICS computers on which malicious objects were...
Philips Gemini PET/CT Family 访问控制错误漏洞
The Philips Philips Gemini PET/CT Family is a medical device from the Dutch company Philips. It is used to achieve more effective treatment processes, greater workflow efficiency and higher return on investment. The Philips Gemini PET/CT Family suffers from an Access Control Error vulnerability...
Philips Gemini PET/CT Family
1. EXECUTIVE SUMMARY CVSS v3 2.4 ATTENTION: Low skill level to exploit Vendor: Philips Equipment: Gemini PET/CT Family Vulnerability: Storage of Sensitive Data in a Mechanism Without Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability involving removable media could...
The vulnerability of the McAfee File and Removable Media Protection software lies in the absence of quotation marks in the syntax of certain elements or search paths. This allows attackers to exploit their privileges or execute arbitrary code.
The vulnerability of the McAfee File and Removable Media Protection software lies in the absence of quotation marks in the code for elements or search paths. Exploiting this vulnerability can allow an attacker to enhance their privileges or execute arbitrary code...
McAfee File and Removable Media Protection (FRP) Installed (Windows)
Binary data mcafeefrpinstalled.nbin...
McAfee File and Removable Media Protection < 5.3.0.143 Arbitrary Code Execution Vulnerability (SB10330)
The version of McAfee File and Removable Media Protection installed on the remote host is prior to 5.3.0.143. It is, therefore, affected by an arbitrary code execution vulnerability which allows local users to execute arbitrary code, with higher privileges. C Tenable Network Security, Inc...
CVE-2020-7316
Unquoted service path vulnerability in McAfee File and Removable Media Protection FRP prior to 5.3.0 allows local users to execute arbitrary code, with higher privileges, via execution and from a compromised folder. This issue may result in files not being encrypted when a policy is triggered...
CVE-2020-7316
Unquoted service path vulnerability in McAfee File and Removable Media Protection FRP prior to 5.3.0 allows local users to execute arbitrary code, with higher privileges, via execution and from a compromised folder. This issue may result in files not being encrypted when a policy is triggered...
Design/Logic Flaw
Unquoted service path vulnerability in McAfee File and Removable Media Protection FRP prior to 5.3.0 allows local users to execute arbitrary code, with higher privileges, via execution and from a compromised folder. This issue may result in files not being encrypted when a policy is triggered...
CVE-2020-7316 File and Removable Media Protection update fixes one vulnerability
Unquoted service path vulnerability in McAfee File and Removable Media Protection FRP prior to 5.3.0 allows local users to execute arbitrary code, with higher privileges, via execution and from a compromised folder. This issue may result in files not being encrypted when a policy is triggered...
Threat landscape for industrial automation systems. H1 2020 highlights
Overall downward trend for percentages of attacked computers globally Beginning in H2 2019 we have observed a tendency for decreases in the percentages of attacked computers, both in the ICS and in the corporate and personal environments. In H1 2020 the percentage of ICS computers on which...
CVE-2020-10126
NCR SelfServ ATMs running APTRA XFS 05.01.00 do not properly validate softare updates for the bunch note acceptor BNA, enabling an attacker with physical access to internal ATM components to restart the host computer and execute arbitrary code with SYSTEM privileges because while booting, the...
Information Disclosure
xen is vulnerable to information disclosure. The vulnerability exists as a flaw was found in the QEMU block format auto-detection, when running fully-virtualized guests and using Qemu images written on removable media USB storage, 3.5" disks. Privileged users of such fully-virtualized guests DomU...
CVE-2019-11687
An issue was discovered in the DICOM Part 10 File Format in the NEMA DICOM Standard 1995 through 2019b and continuing in current implementations. The 128-byte preamble of a DICOM file that complies with this specification can contain arbitrary executable headers for multiple operating systems,...
CVE-2019-11687
An issue was discovered in the DICOM Part 10 File Format in the NEMA DICOM Standard 1995 through 2019b and continuing in current implementations. The 128-byte preamble of a DICOM file that complies with this specification can contain arbitrary executable headers for multiple operating systems,...
USB threats from malware to miners
Introduction In 2016, researchers from the University of Illinois left 297 unlabelled USB flash drives around the university campus to see what would happen. 98% of the dropped drives were picked up by staff and students, and at least half were plugged into a computer in order to view the content...
udisks2 2.8.0 - Denial of Service (PoC)
Exploit: udisks2 2.8.0 - Denial of Service PoC Author: oxagast Date: 2018-09-22 Vendor Homepage: http://storaged.org/ Software Link: https://github.com/storaged-project/udisks Version: =udisks2 2.8.0 Tested on: Ubuntu x64 / / / \ / / / O / / \ \ /\//\// ========The vulnerable section of code...
Microsoft Windows: Devices: Allowed to format and eject removable media
This test checks the setting for policy OpenVAS Vulnerability Test $Id: windevicesformatejectremovable.nasl 11532 2018-09-21 19:07:30Z cfischer $ Check value for Devices: Allowed to format and eject removable media Authors: Emanuel Moss Copyright: Copyright c 2018 Greenbone Networks GmbH,...
CVE-2017-14014
Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...
Hardcoded credentials