Lucene search
+L

47 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/07/14 12:00 a.m.•3 views

CVE-2021-22780: Insufficiently Protected Credentials

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

7.1CVSS5.9AI score0.00217EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/07/14 12:00 a.m.•4 views

CVE-2021-22782: Missing Encryption of Sensitive Data

Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

5.5CVSS5.6AI score0.00109EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/07/14 12:00 a.m.•3 views

CVE-2021-22779: Authentication Bypass by Spoofing

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, SCADAPack...

9.1CVSS5.8AI score0.01023EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/07/14 12:00 a.m.•3 views

CVE-2021-22778: Insufficiently Protected Credentials

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

7.1CVSS5.8AI score0.00216EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/07/14 12:00 a.m.•5 views

CVE-2021-22781: Insufficiently Protected Credentials

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, and SCADAPack RemoteConnect for x70, all version...

5.5CVSS5.6AI score0.00236EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2021/07/13 12:00 a.m.•11 views

PT-2021-7077 · Schneider Electric · Scadapack Remoteconnect For X70 +4

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert versions prior to V15.0 SP1 EcoStruxure Process Expert all versions SCADAPack RemoteConnect for x70 all versions Modicon M580 CPU all versions - part numbers BMEP and BMEH Modicon M340 CPU all versions - part number...

9.4CVSS9.3AI score0.01023EPSS
SaveExploits0References9
Prion
Prion
•added 2020/09/16 4:15 p.m.•20 views

Improper access control

A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect V3.6.3.574 and prior which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user...

6.8CVSS7.6AI score0.00817EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder