152 matches found
Siemens CP-8031 路径遍历漏洞
The ICAM A8000 RTU Remote Terminal Unit series is a modular family of devices for remote control and automation applications in all areas of energy supply. A path traversal vulnerability exists in the Siemens SICAM A8000 device CPCI85 firmware web server, which can be exploited by an attacker to...
CVE-2022-4608
A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of...
CVE-2023-36608
The affected TBox RTUs store hashed passwords using MD5 encryption, which is an insecure encryption algorithm...
Siemens SICAM A8000 Devices CPCI85 Firmware Command Injection Vulnerability
The SICAM A8000 RTUs Remote Terminal Units series is a modular device family for remote control and automation applications in all areas of energy supply. A command injection vulnerability exists in the Siemens SICAM A8000 Devices CPCI85 Firmware, which can be exploited by an attacker to execute...
Siemens CP-8031 MASTER MODULE 命令注入漏洞
The SICAM A8000 RTUs Remote Terminal Units series is a modular device family for remote control and automation applications in all areas of energy supply. A command injection vulnerability exists in the Siemens SICAM A8000 Devices CPCI85 Firmware, which can be exploited by an attacker to execute...
CISA Issues Advisory on Critical RCE Affecting ME RTU Remote Terminal Units
The U.S. Cybersecurity and Infrastructure Security Agency CISA on Tuesday released an Industrial Control Systems ICS advisory about a critical flaw affecting ME RTU remote terminal units. The security vulnerability, tracked as CVE-2023-2131, has received the highest severity rating of 10.0 on the...
The vulnerability of the microprogramming software in the remote terminal block INEA ME RTU arises from the lack of measures taken to neutralize special elements used in the operating system’s commands. This allows a perpetrator to execute arbitrary code.
The vulnerability of the microprogrammed remote terminal block INEA ME RTU exists due to the lack of measures taken to neutralize special elements used in the operating system commands. Exploiting this vulnerability allows a malicious actor to execute arbitrary code remotely...
Schneider Electric Easergy Builder Code Issue Vulnerability
Schneider Electric Easergy Builder is a set of configuration software for Easergy remote terminal units and controllers from Schneider Electric, France. A code issue vulnerability exists in Schneider Electric Easergy Builder version 1.7.23 and earlier, which stems from the presence of an...
CISA Releases One Industrial Control Systems Advisory
CISA released one Industrial Control Systems ICS advisory on April 20, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories for technical...
INEA ME RTU 操作系统命令注入漏洞
The INEA ME RTU is a remote terminal unit from INEA. It implements the data interface between the remote device and the control center. A security vulnerability exists in INEA ME RTU version 3.36 and earlier, which stems from the presence of an operating system command injection vulnerability. Th...
Hitachi Energy RTU500 安全漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A buffer overflow vulnerability exists in the Hitachi Energy RTU500 series CMU firmware HCI Modbus TCP function. The vulnerability, which originates when HCI Modbus TCP is enabled a...
CVE-2022-30262
The Emerson ControlWave 'Next Generation' RTUs through 2022-05-02 mishandle firmware integrity. They utilize the BSAP-IP protocol to transmit firmware updates. Firmware updates are supplied as CAB archive files containing a binary firmware image. In all cases, firmware images were found to have n...
CVE-2022-30264
The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol 4000/TCP, 5000/TCP for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the...
Siemens SICAM A8000 Web Server Module Authentication Bypass Vulnerability
The SICAM A8000 RTU Remote Terminal Unit series is a modular device family for remote control and automation applications in all energy supply areas.An authentication bypass vulnerability exists in the Siemens SICAM A8000 Web Server Module, which is caused by the component allowing the activation...
Emerson ControlWave 数据伪造问题漏洞
Emerson ControlWave is a highly programmable controller from Emerson Electric U.S. that combines the unique capabilities of a Programmable Logic Controller PLC and a Remote Terminal Unit RTU into a hybrid controller. A data forgery vulnerability exists in all versions of Emerson ControlWave, whic...
CVE-2022-30270
The Motorola ACE1000 RTU through 2022-05-02 has default credentials. It exposes an SSH interface on port 22/TCP. This interface is used for remote maintenance and for SFTP file-transfer operations that are part of engineering software functionality. Access to this interface is controlled by 5...
CVE-2022-29960
Emerson OpenBSI through 2022-04-29 uses weak cryptography. It is an engineering environment for the ControlWave and Bristol Babcock line of RTUs. DES with hardcoded cryptographic keys is used for protection of certain system credentials, engineering files, and sensitive utilities...
Emerson OpenBSI 加密问题漏洞
Emerson OpenBSI is a set of web-based communication services designed for technicians, engineers, and operators from Emerson Electric USA that provide access to ControlWave RTUs. A security vulnerability exists in versions of Emerson OpenBSI prior to 2022-04-29 that stems from the use of weak...
Siemens SICAM A8000 CPC80 has an unspecified vulnerability
The SICAM A8000 RTU Remote Terminal Unit series is a modular device family for remote control and automation applications in all areas of energy supply.A security vulnerability exists in the Siemens SICAM A8000 CPC80, which stems from the fact that when using an HTTPS server under certain...
CVE-2022-34761
A CWE-476: NULL Pointer Dereference vulnerability exists that could cause a denial of service of the webserver when parsing JSON content type. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication Module BMENUA0100 V1.10 and prior...