Lucene search
+L

71 matches found

OSV
OSV
added 2022/05/02 7:15 p.m.6 views

CVE-2022-28613

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The...

7.5CVSS5.8AI score0.00951EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/05/02 12:0 a.m.13 views

Hitachi Energy RTU500 输入验证错误漏洞

Hitachi Energy RTU500 is a series of industrial control components from Hitachi, Ltd Hitachi, Japan. The Hitachi Energy RTU500 suffers from an input validation error vulnerability that stems from a length information validation error carried in MBAP. An attacker could exploit the vulnerability by...

7.8CVSS7.3AI score0.00951EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2022/04/12 12:0 a.m.5 views

Siemens SICAM 访问控制错误漏洞

The SICAM A8000 RTU Remote Terminal Unit series is used for automation applications in all areas of remote control and energy supply. An unauthorized access vulnerability exists in the Siemens SICAM A8000 CP-8050 and CP-8031, which can be exploited by an attacker to access files without...

7.5CVSS7.4AI score0.02446EPSS
SaveExploits1References7
ATTACKERKB
ATTACKERKB
added 2022/01/28 8:15 p.m.5 views

CVE-2021-22816

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334...

7.8CVSS7.1AI score0.00947EPSS
SaveExploits0References2
ICS
ICS
added 2021/12/07 12:0 a.m.41 views

Hitachi Energy RTU500 OpenLDAP

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 Series Vulnerabilities: Type Confusion, Reachable Assertion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a denial-of-service condition...

7.5CVSS8.2AI score0.1229EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2021/10/15 12:0 a.m.5 views

Mitsubishi Electric smartRTU 跨站脚本漏洞

The Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric Japan. A cross-site scripting vulnerability exists in the Mitsubishi Electric SmartRTU device that stems from the lack of valid validation and escaping of the username and PATHINFO parameters in t...

6.1CVSS5.9AI score0.04032EPSS
SaveExploits4References4
BDU FSTEC
BDU FSTEC
added 2021/09/02 12:0 a.m.11 views

The vulnerability of the RTU module’s microprogramming software, Modicon BMXNOR0200H, due to lack of access control mechanisms, allows intruders to gain increased privileges.

The vulnerability of the RTU module’s microprogramming software, Modicon BMXNOR0200H, is related to lack of access control mechanisms. Exploiting this vulnerability could allow an attacker operating remotely to enhance their privileges...

8.6CVSS7.6AI score0.01729EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2021/06/08 12:0 a.m.7 views

BMXNOR0200H Ethernet/Serial RTU module 信息泄露漏洞

The Schneider Electric BMXNOR0200H Ethernet/Serial RTU module is an Ethernet Serial RTU Remote Terminal Unit module from Schneider Electric France. An information disclosure vulnerability exists in the Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and earlier versions, which originates when a specially...

5.3CVSS6.7AI score0.00925EPSS
SaveExploits0References5
ICS
ICS
added 2020/12/08 12:0 a.m.50 views

Siemens SICAM A8000 RTUs

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SICAM A8000 Remote Terminal Unit Series Vulnerability: Protection Mechanism Failure 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to...

7.3CVSS7.6AI score0.00564EPSS
SaveExploits0References9
OSV
OSV
added 2020/06/26 5:15 p.m.5 views

CVE-2020-10628

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes unencrypted passwords on the network...

7.5CVSS5.8AI score0.00743EPSS
SaveExploits0References1
OSV
OSV
added 2020/06/26 5:15 p.m.9 views

CVE-2020-10624

ControlEdge PLC R130.2, R140, R150, and R151 and RTU R101, R110, R140, R150, and R151 exposes a session token on the network...

7.5CVSS7.2AI score0.00743EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/24 12:0 a.m.8 views

Honeywell ControlEdge PLC and ControlEdge RTU Information Disclosure Vulnerability

Honeywell ControlEdge PLC and ControlEdge RTU are both products of Honeywell, Inc. The ControlEdge PLC is a programmable logic controller PLC.The ControlEdge RTU is a remote terminal unit RTU. An information disclosure vulnerability exists in the Honeywell ControlEdge PLC and RTU, which can be...

7.5CVSS6.4AI score0.00743EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/24 12:0 a.m.6 views

Honeywell ControlEdge PLC and ControlEdge RTU Information Disclosure Vulnerability (CNVD-2020-37479)

Honeywell ControlEdge PLC and ControlEdge RTU are both products of Honeywell, Inc. The ControlEdge PLC is a programmable logic controller PLC.The ControlEdge RTU is a remote terminal unit RTU. An information disclosure vulnerability exists in the Honeywell ControlEdge PLC and RTU that can be...

7.5CVSS6.4AI score0.00743EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/17 12:0 a.m.16 views

Unspecified Vulnerability in Schneider Electric Easergy T300 (CNVD-2021-21480)

The Schneider Electric Easergy T300 is a remote terminal unit for the power industry from Schneider Electric, France. A security vulnerability exists in the Schneider Electric Easergy T300 using firmware version 1.5.2 and earlier, which can be exploited by an attacker...

9.8CVSS7.1AI score0.01433EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/17 12:0 a.m.12 views

Schneider Electric Easergy T300 Information Disclosure Vulnerability (CNVD-2021-21474)

The Schneider Electric Easergy T300 is a remote terminal unit for the power industry from Schneider Electric, France. An information disclosure vulnerability exists in the Schneider Electric Easergy T300 using firmware version 1.5.2 and earlier, which can be exploited by an attacker to obtain...

7.5CVSS6.5AI score0.0131EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/04/08 12:0 a.m.9 views

Synergy Systems & Solutions HUSKY RTU 6049-E70 Access Control Error Vulnerability (CNVD-2020-25373)

Synergy Systems & Solutions HUSKY RTU 6049-E70 is a Remote Terminal Unit RTU from Synergy Systems & Solutions, India. The Synergy Systems & Solutions HUSKY RTU 6049-E70 is vulnerable to an access control error that can be exploited by an attacker to view the network configuration via SNMP...

5.3CVSS6.9AI score0.00898EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/04/08 12:0 a.m.34 views

Synergy Systems & Solutions HUSKY RTU 6049-E70 Access Control Error Vulnerability

Synergy Systems & Solutions HUSKY RTU 6049-E70 is a Remote Terminal Unit RTU from Synergy Systems & Solutions, India. The Synergy Systems & Solutions HUSKY RTU 6049-E70 suffers from an Access Control Error vulnerability that can be exploited by an attacker to change the configuration or perform...

9.8CVSS7AI score0.0137EPSS
SaveExploits0References1
OSV
OSV
added 2020/02/14 5:15 p.m.4 views

CVE-2019-20046

The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue...

9.8CVSS6.9AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2020/01/23 12:0 a.m.10 views

Servelec Technologies TBox Remote Terminal Unit

Binary data 701264.prm...

7.3AI score
SaveExploits0
VulnCheck KEV
VulnCheck KEV
added 2019/12/13 12:0 a.m.5 views

VulnCheck KEV: CVE-2019-14931

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to...

10CVSS7.6AI score0.5766EPSS
SaveExploits3References1
Rows per page