335 matches found
Siemens SINEMA Remote Connect Server 命令注入漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. Siemens SINEMA Remote Connect Server suffers from a command injection vulnerability that can be...
Siemens SINEMA Remote Connect Server 安全漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. A security vulnerability exists in Siemens SINEMA Remote Connect Server, which can be exploited by an...
CVE-2024-39866: Privilege Defined With Unsafe Actions
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with...
CVE-2024-39875: Incorrect Permission Assignment for Critical Resource
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. The affected application allows authenticated, low privilege users with the 'Manage own remote connections' permission to retrieve details about other users and group memberships...
CVE-2024-39872: Creation of Temporary File With Insecure Permissions
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the 'Manage firmware updates' role to escalate...
CVE-2024-39869: Improper Check for Unusual or Exceptional Conditions
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the...
CVE-2024-39876: Allocation of Resources Without Limits or Throttling
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device...
CVE-2024-39865: Unrestricted Upload of File with Dangerous Type
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. The affected application allows users to upload encrypted backup files. As part of this backup, files can be restored without correctly checking the path of the restored file. This could allow an attacker...
Siemens SINEMA Remote Connect Server 安全漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. A security vulnerability exists in Siemens SINEMA Remote Connect Server due to an affected applicatio...
Siemens SINEMA Remote Connect 安全漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. A security vulnerability exists in Siemens SINEMA Remote Connect Server, which can be exploited by an...
CVE-2024-39868: Direct Request
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of...
CVE-2024-39871: Incorrect Authorization
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage...
CVE-2024-39873: Improper Restriction of Excessive Authentication Attempts
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force...
CVE-2024-39870: Client-Side Enforcement of Server-Side Security
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate...
CVE-2024-39867: Direct Request
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of...
Siemens SINEMA Remote Connect Server 安全漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. A security vulnerability exists in Siemens SINEMA Remote Connect Server because the affected...
Siemens SINEMA Remote Connect 安全漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. Siemens SINEMA Remote Connect Server suffers from a forced browsing vulnerability, which is caused du...
Siemens SINEMA Remote Connect 安全漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. An incorrect authorization vulnerability exists in Siemens SINEMA Remote Connect Server, which can be...
CVE-2024-39874: Improper Restriction of Excessive Authentication Attempts
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 SP1. The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are...
CVE-2024-39570: Improper Neutralization of Special Elements used in a Command
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.2 HF1. Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code...