6094 matches found
CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2019-25720
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2019-25720
This CVE affects Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). The vulnerability is a denial-of-service caused by processing a malformed network packet, allowing an unauthenticated attacker to reboot the monitor. Repeated malformed packets can disrupt patient ...
CVE-2026-46249
In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...
EUVD-2026-34111
In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...
CVE-2026-46249 octeontx2-af: Fix PF driver crash with kexec kernel booting
In the Linux kernel, the following vulnerability has been resolved: octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist into the new kernel. When AF and PF drivers are built as modules, the...
CVE-2026-46249
The CVE-2026-46249 issue affects the Linux kernel octeontx2-af PF driver. During a kexec reboot, the old AF state may persist if the PF driver probes before AF reinitializes, and if the RVUM block revision is not cleared on shutdown, PF can mis-detect AF readiness and access stale hardware, leadi...
EUVD-2022-55996
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
Linux kernel 安全漏洞
The Linux kernel is the core of the open-source operating system Linux, developed by the Linux Foundation in the United States. There is a security vulnerability in the Linux kernel, which stems from the octeontx2-af driver failing to clear the RVUM block revision during kexec reboot. This causes...
Linux Distros Unpatched Vulnerability : CVE-2026-46249
The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - octeontx2-af: Fix PF driver crash with kexec kernel booting During a kexec reboot the hardware is not power-cycled, so AF state from the old kernel can persist...
PT-2026-45983
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2022-4992
CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...
CVE-2019-25721
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
EUVD-2019-20160
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25722
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
CVE-2019-25722
The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...