2269 matches found
CVE-2009-1797
Multiple cross-site request forgery CSRF vulnerabilities on the Network Management Card NMC on American Power Conversion APC Switched Rack PDU aka Rack Mount Power Distribution devices and other devices allow remote attackers to hijack the authentication of 1 administrator or 2 device users for...
CVE-2009-4406
Cross-site scripting XSS vulnerability in Forms/login1 in American Power Conversion APC Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the loginusername parameter...
Cross site scripting
Cross-site scripting XSS vulnerability in Forms/login1 in American Power Conversion APC Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the loginusername parameter...
CVE-2009-4406
Cross-site scripting XSS vulnerability in Forms/login1 in American Power Conversion APC Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the loginusername parameter...
CVE-2009-4406
CVE-2009-4406 is an XSS in the APC Network Monitoring/Card web interface. The vulnerability affects the NMC login form: Forms/login1?login_username on AP7932 B2 devices (rpdu 3.3.3 or 3.7.0 on AOS 3.3.4 and possibly other versions) allowing remote attackers to inject arbitrary script/HTML. Conseq...
APC Switched Rack PDU Cross Site Scripting
APC Switched Rack PDU XSS Vulnerability By Jamal Pecou jpecou at gmail dot c0m. Product Info Product InfoTested Versions Model = AP7932 Harware Revision = B2 Application Module Name = rpdu Version = v3.3.3Tested First Version = 3.7.0Current APC OS AOS Name = aos Version = v3.3.4 Vulnerability XSS...
APC Switched Rack PDU XSS Vulnerability
APC Switched Rack PDU XSS Vulnerability By Jamal Pecou jpecou at gmail dot c0m. Product Info Product InfoTested Versions Model = AP7932 Harware Revision = B2 Application Module Name = rpdu Version = v3.3.3Tested First Version = 3.7.0Current APC OS AOS Name = aos Version = v3.3.4 Vulnerability XSS...
APC Switched Rack PDU crossite scripting
Crossite scripting in Web administration interface...
APC Management Vulnerability
We have found a security exploit in the latest APC firmware versions for there switched rack PDU products. We have only tested this against the version listed below on a AP7932 0u 30amp PDU. Name: rpdu Version: v3.5.5 Date: 07/18/2007 Time: 11:38:29 Name: aos Version: v3.5.6 Date: 07/18/2007 Time...