Lucene search
+L

2280 matches found

NVD
NVD
added 2022/01/28 8:15 p.m.38 views

CVE-2021-22814

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

6.1CVSS0.00745EPSS
SaveExploits0References1
NVD
NVD
added 2022/01/28 8:15 p.m.38 views

CVE-2021-22815

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 NMC2: AP9630/AP9630CH/AP9630J,...

5.3CVSS0.00768EPSS
SaveExploits0References1
OSV
OSV
added 2022/01/28 8:15 p.m.6 views

CVE-2021-22815

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 NMC2: AP9630/AP9630CH/AP9630J,...

5.3CVSS6AI score0.00768EPSS
SaveExploits0References1
Prion
Prion
added 2022/01/28 8:15 p.m.23 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power...

4.3CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2022/01/28 7:09 p.m.78 views

CVE-2021-22815

The CVE-2021-22815 entry covers an Information Exposure vulnerability in Schneider Electric NMC/NMC2/NMC3 embedded devices and related APC equipment. Affected products include 1-phase and 3-phase UPS with NMC2/NMC3 (AP9630/9631/9635 on NMC2; AP9640/9641/9643 on NMC3), NMC2/NMC3-based PDUs, XRDP/X...

5.3CVSS5.2AI score0.00768EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/01/28 7:09 p.m.33 views

CVE-2021-22814

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

6.5AI score0.00745EPSS
SaveExploits0References1
CVE
CVE
added 2022/01/28 7:09 p.m.61 views

CVE-2021-22814

CVE-2021-22814 describes a Cross-site Scripting (CWE-79) vulnerability in Schneider Electric NMC embedded devices (NMC2 and NMC3) that can cause arbitrary script execution when a malicious file is read and displayed. Affected products span multiple Schneider Electric lines: 1-phase and 3-phase UP...

6.1CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/01/28 7:09 p.m.48 views

CVE-2021-22813

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...

6.4AI score0.00745EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/01/28 7:09 p.m.32 views

CVE-2021-22811

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply UP...

6.5AI score0.00745EPSS
SaveExploits0References1
OpenVAS
OpenVAS
added 2022/01/28 12:00 a.m.28 views

Mageia: Security Advisory (MGASA-2020-0252)

The remote host is missing an update for the SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

8.6CVSS7AI score0.03703EPSS
SaveExploits0References7
OpenVAS
OpenVAS
added 2022/01/28 12:00 a.m.10 views

Mageia: Security Advisory (MGASA-2014-0156)

The remote host is missing an update for the SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

4.3CVSS6.6AI score0.0219EPSS
SaveExploits1References4
OpenVAS
OpenVAS
added 2022/01/28 12:00 a.m.24 views

Mageia: Security Advisory (MGASA-2018-0449)

The remote host is missing an update for the SPDX-FileCopyrightText: 2022 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

6.1CVSS6.5AI score0.0189EPSS
SaveExploits0References4
OSV
OSV
added 2022/01/21 7:15 p.m.9 views

CVE-2021-23236

Requests may be used to interrupt the normal operation of the device. When exploited, Fresenius Kabi Agilia Link+ version 3.0 must be rebooted via a hard reset triggered by pressing a button on the rack system...

7.5CVSS7.1AI score0.0107EPSS
SaveExploits0References1
ICS
ICS
added 2021/12/14 12:00 a.m.86 views

Schneider Electric Rack PDU (Update A)

1. EXECUTIVE SUMMARY --------- Begin Update A Part 1 of 3 --------- CVSS v3 6.5 ATTENTION: Exploitable remotely --------- End Update A Part 1 of 3 --------- Vendor: Schneider Electric Equipment: Rack Power Distribution Unit PDU --------- Begin Update A Part 2 of 3 --------- Vulnerability:...

8CVSS8.1AI score0.00774EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2021/12/14 12:00 a.m.34 views

Schneider Electric Rack PDU 信息泄露漏洞

Schneider Electric Rack PDUs are APC switched rack power distribution units PDUs from Schneider-electric in France that support advanced, user-customizable power control and active monitoring. An information disclosure vulnerability exists in the Schneider Electric Rack PDU, which can be exploite...

8CVSS7.7AI score0.00774EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2021/11/05 12:00 a.m.33 views

Rack-Mini-Profiler Information Disclosure

Rack-Mini-Profiler is a middleware that displays a speed badge for each html page. Designed to work in both production and development but when the 'enableadvanceddebuggingtools' option is selected it is possible to access sensitive information such as environment variables and other secrets stor...

6.6AI score
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2021/10/21 12:00 a.m.7 views

The vulnerability of HTTP servers for Ruby/Rack applications developed with Puma, related to uncontrolled resource consumption, allows attackers to cause service failures.

The vulnerability of HTTP servers for Ruby/Rack applications developed with Puma is related to an uncontrolled resource consumption. Exploiting this vulnerability can allow a malicious actor to cause service failures remotely...

7.8CVSS6.4AI score0.01599EPSS
SaveExploits0References6Affected Software2
CVE
CVE
added 2021/10/12 3:30 p.m.168 views

CVE-2021-41136

Summary: CVE-2021-41136 affects Puma HTTP/1.1 server for Ruby/Rack. When used with a proxy that forwards HTTP header values containing LF, an attacker could smuggle a request through the proxy, potentially causing the proxy to send a response to a different client. This behavior has been observed...

3.7CVSS5.8AI score0.01203EPSS
SaveExploits0References7Affected Software1
BDU FSTEC
BDU FSTEC
added 2021/09/20 12:00 a.m.13 views

The vulnerability of an organization’s software for app compatibility with Rack and CORS allows a hacker to access confidential data by exploiting improper pathname restrictions on the directory.

The vulnerability of an organization’s application compatibility software for Rack applications with CORS Rack-cors is related to incorrect handling of the path name. Exploiting this vulnerability can allow a malicious actor to gain access to confidential data...

5.3CVSS5.9AI score0.02462EPSS
SaveExploits0References4Affected Software2
OSV
OSV
added 2021/09/17 8:15 p.m.13 views

CVE-2021-38412

Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to...

9.8CVSS5.8AI score0.01342EPSS
SaveExploits0References1
Rows per page
Query Builder