1916 matches found
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49924)
fbdev: pxafb:use after free in pxafbtask. In the pxafbprobe function, it calls the pxafbinitfbinfo function, after which &fbi-task is associated with pxafbtask. Moreover, within this pxafbinitfbinfo function, the pxafbblank function within the &pxafbops struct is capable of scheduling work. If we...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41065)
powerpc/pseries: Reading the dispatch trace log from /sys/kernel/debug/powerpc/dtl/cpu- results in a BUG. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49882)
ext4: In ext4exttrytomergeup, path1.pbh should be set to NULL after it has been released, otherwise it may be released twice. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41040)
net/sched: UAF when resolving a clash. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504485; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices NULL Pointer Dereference (CVE-2024-47749)
RDMA/cxgb4: Added NULL check for lookupatid. The lookupatid function can return NULL if the ATID is invalid or does not exist in the identifier table, which could lead to dereferencing a null pointer without a check in the actestablish and actopenrpl functions. This plugin only works with...
Siemens SCALANCE and RUGGEDCOM Devices Use of Uninitialized Resource (CVE-2024-50273)
btrfs: reinitialize delayed ref list after deleting it from the list. At insertdelayedref if there is a need to update the action of an existing ref to BTRFSDROPDELAYEDREF, the ref from its ref head's refaddlist is deleted using listdel, which leaves the ref's addlist member not reinitialized, as...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46771)
can: bcm: Remove proc entry when dev is unregistered. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504624; scriptversion"1.3";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53239)
ALSA: 6fire: The current 6fire code tries to release the resources right after the call of usb6firechipabort. But at this moment, the card object might be still in use as we're calling sndcardfreewhenclosed and cause potential UAFs. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM ROS Devices Heap-based Buffer Overflow (CVE-2021-42018)
Within a third-party component, whenever memory allocation is requested, the out of bound size is not checked. Therefore, if size exceeding the expected allocation is assigned, it could allocate a smaller buffer instead. If an attacker were to exploit this, they could cause a heap overflow. This...
Siemens RUGGEDCOM ROS Devices Observable Timing Discrepancy (CVE-2021-42016)
A timing attack, in a third-party component, could make the retrieval of the private key possible, used for encryption of sensitive data. If a threat actor were to exploit this, the data integrity and security could be compromised. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM ROS Devices Improperly Implemented Security Check for Standard (CVE-2021-42017)
A new variant of the POODLE attack has left a third-party component vulnerable due to the implementation flaws of the CBC encryption mode in TLS 1.0 to 1.2. If an attacker were to exploit this, they could act as a man-in-the-middle and eavesdrop on encrypted communications. This plugin only works...
Siemens RUGGEDCOM ROS Devices Improper Check for Unusual or Exceptional Conditions (CVE-2021-42020)
The third-party component, in its TFTP functionality fails to check for null terminations in file names. If an attacker were to exploit this, it could result in data corruption, and possibly a hard-fault of the application. This plugin only works with Tenable.ot. Please visit...
Siemens RUGGEDCOM ROS Devices Integer Overflow or Wraparound (CVE-2021-42019)
Within a third-party component, the process to allocate partition size fails to check memory boundaries. Therefore, if a large amount is requested by an attacker, due to an integer-wrap around, it could result in a small size being allocated instead. This plugin only works with Tenable.ot. Please...
Siemens RUGGEDCOM ROS Devices Improper Neutralization of Input During Web Page Generation (CVE-2021-37208)
Improper neutralization of special characters on the web server configuration page could allow an attacker, in a privileged position, to retrieve sensitive information via cross-site scripting. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...
Siemens RUGGEDCOM ROX II Unrestricted Upload of File with Dangerous Type (CVE-2025-33023)
The affected devices do not properly enforce the restriction of files that can be uploaded from the web interface. This could allow an authenticated remote attacker with high privileges in the web interface to upload arbitrary files. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-0584)
A use-after-free issue was found in igmpstarttimer in net/ipv4/igmp.c in the network sub-component in the Linux Kernel. This flaw allows a local user to observe a refcnt use-after-free issue when receiving an igmp query packet, leading to a kernel information leak. This plugin only works with...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Buffer Underwrite (CVE-2024-49949)
In the Linux kernel, the following vulnerability has been resolved: net: avoid potential underflow in qdiscpktleninit with UFO. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Out-of-bounds Read (CVE-2024-50301)
In the Linux kernel, the following vulnerability has been resolved: security/keys: fix slab-out-of-bounds in keytaskpermission. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices NULL Pointer Dereference (CVE-2024-50045)
In the Linux kernel, the following vulnerability has been resolved: netfilter: brnetfilter: fix panic with metadatadst skb. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc...
Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Out-of-bounds Read (CVE-2024-46743)
In the Linux kernel, the following vulnerability has been resolved: of/irq: Prevent device address out-of-bounds read in interrupt map walk. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...