43 matches found
Siemens RUGGEDCOM 跨站脚本漏洞
Siemens RuggedCom ROS is an operating system used in the RuggedCom family of switches from Siemens, Germany. Siemens RUGGEDCOM ROS is vulnerable to cross-site scripting, which can be exploited by attackers to retrieve sensitive information via cross-site scripting...
Siemens RUGGEDCOM 安全特征问题漏洞
Siemens RuggedCom ROS is an operating system used in the RuggedCom family of switches from Siemens, Germany. Siemens RUGGEDCOM ROS has a security vulnerability that could be exploited by attackers to act as a man-in-the-middle and eavesdrop on encrypted communications...
Siemens RUGGEDCOM 缓冲区错误漏洞
Siemens RuggedCom ROS is an operating system used in the RuggedCom family of switches from Siemens, Germany. Siemens RUGGEDCOM ROS suffers from a heap buffer overflow vulnerability that can be exploited by attackers to cause a heap overflow...
CVE-2021-31895
A vulnerability has been identified in RUGGEDCOM i800 All versions V4.3.7, RUGGEDCOM i801 All versions V4.3.7, RUGGEDCOM i802 All versions V4.3.7, RUGGEDCOM i803 All versions V4.3.7, RUGGEDCOM M2100 All versions V4.3.7, RUGGEDCOM M2200 All versions V4.3.7, RUGGEDCOM M969 All versions V4.3.7,...
Remote code execution
A vulnerability has been identified in RUGGEDCOM ROS M2100 All versions V4.3.7, RUGGEDCOM ROS M2200 All versions V4.3.7, RUGGEDCOM ROS M969 All versions V4.3.7, RUGGEDCOM ROS RMC All versions V4.3.7, RUGGEDCOM ROS RMC20 All versions V4.3.7, RUGGEDCOM ROS RMC30 All versions V4.3.7, RUGGEDCOM ROS...
CVE-2021-31895
A vulnerability has been identified in RUGGEDCOM i800 All versions V4.3.7, RUGGEDCOM i801 All versions V4.3.7, RUGGEDCOM i802 All versions V4.3.7, RUGGEDCOM i803 All versions V4.3.7, RUGGEDCOM M2100 All versions V4.3.7, RUGGEDCOM M2200 All versions V4.3.7, RUGGEDCOM M969 All versions V4.3.7,...
CVE-2021-31895
CVE-2021-31895 affects Siemens RUGGEDCOM ROS and ROS-derived devices (e.g., i800/i801/i802/i803, M2100/M2200, RMC/RMC8388/RSG series, RS/RL/RST series, etc.) across versions prior to 4.3.7 (and some 5.x lines). The underlying issue is a DHCP client that fails to properly sanitize incoming DHCP pa...
Siemens RUGGEDCOM ROS
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION : Exploitable remotely Vendor : Siemens Equipment : RUGGEDCOM ROS Vulnerability : Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker with network access to an affected device to cause a remote...
Siemens RUGGEDCOM ROS (Update A)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Design/Logic Flaw
A vulnerability has been identified in RUGGEDCOM ROS for RSL910 devices All versions ROS V5.0.1, RUGGEDCOM ROS for all other devices All versions ROS V4.3.4, SCALANCE XB-200/XC-200/XP-200/XR300-WG All versions between V3.0 including and V3.0.2 excluding, SCALANCE XR-500/XM-400 All versions betwee...
CVE-2017-12736
CVE-2017-12736 affects Siemens Ruggedcom ROS and SCALANCE devices. After initial configuration, the Ruggedcom Discovery Protocol (RCDP) can still write to the device under certain conditions, potentially allowing an attacker in the adjacent network to perform unauthorized administrative actions. ...
PT-2017-12674 · Siemens · Ruggedcom Ros +4
Name of the Vulnerable Software and Affected Versions: RUGGEDCOM ROS for RSL910 devices versions prior to 5.0.1 RUGGEDCOM ROS for all other devices versions prior to 4.3.4 SCALANCE XB-200/XC-200/XP-200/XR300-WG versions 3.0 through 3.0.2 excluding 3.0.2 SCALANCE XR-500/XM-400 versions 6.1 through...
Siemens Ruggedcom ROS, SCALANCE (Update A)
CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Ruggedcom ROS, SCALANCE Vulnerability: Improper Access Control UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-17-271-01 Siemens Ruggedcom ROS and SCALAN...
Siemens Ruggedcom ROS, SCALANCE
CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: Ruggedcom ROS, SCALANCE Vulnerability: Improper Access Control UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory titled ICSA-17-271-01A Siemens Ruggedcom ROS, SCALANCE...
Siemens RUGGEDCOM ROS Information Disclosure Vulnerability
Siemens RuggedCom ROS and ROX-based devices are used for device connectivity in harsh environments, e.g. substations, traffic management chassis etc. An information disclosure vulnerability exists in Siemens RUGGEDCOM ROS versions prior to 4.2.1. Because the program fails to pad Ethernet frames...
CVE-2014-2590
The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service interface outage via crafted HTTP packets...
Design/Logic Flaw
The web management interface in Siemens RuggedCom ROS before 3.11, ROS 3.11 before 3.11.5 for RS950G, ROS 3.12, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service interface outage via crafted HTTP packets...
CVE-2014-2590
CVE-2014-2590 concerns Siemens RuggedCom ROS web management interface. The vulnerability stems from improper input validation in the HTTP handling of the device’s web server, allowing remote attackers to cause a denial-of-service (interface outage) via specially crafted HTTP packets. Affected pro...
CVE-2014-1966
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service device outage via crafted packets...