823 matches found
Schneider Electric Saitel DR RTU 操作系统命令注入漏洞
The Schneider Electric Saitel DR RTU is a remote terminal device from Schneider Electric France. The Schneider Electric Saitel DR RTU suffers from an operating system command injection vulnerability that stems from improper neutralization of operating system commands, which could lead to command...
PT-2025-48482
Name of the Vulnerable Software and Affected Versions Socomec DIRIS Digiware M-70 version 1.6.9 Description A denial of service issue exists in the Modbus TCP and Modbus RTU over TCP USB Function functionality. An attacker can send an unauthenticated, specially crafted network packet to trigger a...
CVE-2023-2131
Versions of INEA ME RTU firmware prior to 3.36 are vulnerable to OS command injection, which could allow an attacker to remotely execute arbitrary code...
CVE-2022-30271
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts such as /etc/init.d/sshdservice only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default...
CVE-2022-30274
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm TEA in ECB mode using a hardcode...
CVE-2022-30264
The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol 4000/TCP, 5000/TCP for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the...
CVE-2022-30272
The Motorola ACE1000 RTU through 2022-05-02 mishandles firmware integrity. It utilizes either the STS software suite or ACE1000 Easy Configurator for performing firmware updates. In case of the Easy Configurator, firmware updates are performed through access to the Web UI where file system, kerne...
CVE-2020-7801
The Synergy Systems & Solutions SSS HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Exposure of Sensitive Information to an Unauthorized Actor CWE-200 vulnerability. The affected product is vulnerable to information exposure over the SNMP protocol. This is a different issue than...
CVE-2019-14926
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with...
CVE-2019-14930
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin...
CVE-2019-14925
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames,...
CVE-2019-14927
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file which contains data such as usernames,...
CVE-2019-14931
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to t...
CVE-2019-14928
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to...
CVE-2019-20046
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue...
CVE-2019-20045
The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and...
CVE-2025-1445
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...
CVE-2025-1445
CVE-2025-1445 affects Hitachi Energy RTU500 series, specifically the IEC 61850 client/server stack on CMU devices configured with TLS. The issue is a potential availability problem if renegotiation of an active IEC 61850 TLS connection occurs in certain timing scenarios. Precondition: TLS is enab...
CVE-2025-1445
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...
Hitachi Energy RTU500 代码问题漏洞
Hitachi Energy RTU500 is a series of industrial control components from Hitachi, Ltd Hitachi, Japan. A code issue vulnerability exists in the Hitachi Energy RTU500 that stems from a specially crafted message sequence that could lead to a denial of service in the RTU500 CMU application...