Lucene search
+L

823 matches found

Positive Technologies
Positive Technologies
added 2019/10/28 12:00 a.m.10 views

PT-2019-13867 · Mitsubishi · Me-Rtu

Name of the Vulnerable Software and Affected Versions: Mitsubishi Electric Europe B.V. ME-RTU devices versions 2.02 and earlier INEA ME-RTU devices versions 3.0 and earlier Description: An issue allows an attacker to read sensitive configuration settings due to insecure permission assignment. The...

6.5CVSS6.6AI score0.0126EPSS
SaveExploits1References4
CNVD
CNVD
added 2019/09/23 12:00 a.m.10 views

Schneider Electric BMXNOR0200H Ethernet/Serial RTU Module Access Control Error Vulnerability

The Schneider Electric BMXNOR0200H Ethernet/Serial RTU module is an Ethernet Serial RTU Remote Terminal Unit module from Schneider Electric, France. An access control error vulnerability exists in the Schneider Electric BMXNOR0200H Ethernet/Serial RTU module. The vulnerability arises from the...

8.8CVSS6.9AI score0.01729EPSS
SaveExploits0References1
NVD
NVD
added 2019/09/17 8:15 p.m.32 views

CVE-2019-6810

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol...

8.8CVSS8.8AI score0.01729EPSS
SaveExploits0References2
Prion
Prion
added 2019/09/17 8:15 p.m.21 views

Improper access control

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol...

6.5CVSS8.7AI score0.01729EPSS
SaveExploits0References2
Prion
Prion
added 2019/09/17 8:15 p.m.20 views

Design/Logic Flaw

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on por...

5CVSS8.5AI score0.01401EPSS
SaveExploits0References2
CVE
CVE
added 2019/09/17 7:56 p.m.142 views

CVE-2019-6813

The CVE-2019-6813 vulnerability affects Schneider Electric BMXNOR0200H Ethernet/Serial RTU modules and Modicon M340 controllers (all firmware versions). It is a CWE-754 improper check for unusual or exceptional conditions that could cause a denial of service when truncated SNMP packets are receiv...

7.8CVSS7.5AI score0.02084EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2019/09/17 7:52 p.m.147 views

CVE-2019-6810

CVE-2019-6810 affects Schneider Electric BMXNOR0200H Ethernet/Serial RTU module (all firmware versions). The vulnerability is an improper access control that could allow unauthorized users to execute commands when using IEC 60870-5-104. Impact is described as potential remote command execution wi...

8.8CVSS8.7AI score0.01729EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2019/09/17 7:22 p.m.48 views

CVE-2019-6831

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module all firmware versions, which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on por...

8.6AI score0.01401EPSS
SaveExploits0References2
CVE
CVE
added 2019/09/17 7:22 p.m.132 views

CVE-2019-6831

CVE-2019-6831 affects the BMXNOR0200H Ethernet/Serial RTU module (all firmware versions), causing disconnection of active connections when an unusually high number of IEC 60870-5-104 packets are received on port 2404/TCP. Affected CVSS: v3.1 base score 8.6 (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H). E...

8.6CVSS8.5AI score0.01401EPSS
SaveExploits0References2Affected Software1
CNVD
CNVD
added 2019/08/15 12:00 a.m.11 views

Mitsubishi Electric smartRTU and Inea ME-RTU Operating System Command Injection Vulnerability

Mitsubishi Electric smartRTU is an intelligent Remote Terminal Unit RTU from Mitsubishi Electric, Japan.Inea ME-RTU is an intelligent communication gateway product from Inea, Slovenia. An operating system command injection vulnerability exists in Mitsubishi Electric smartRTU version 2.02 and...

10CVSS7.9AI score0.5809EPSS
SaveExploits3References1
Exploit DB
Exploit DB
added 2019/08/12 12:00 a.m.290 views

Mitsubishi Electric smartRTU / INEA ME-RTU - Unauthenticated OS Command Injection Bind Shell

!/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated OS Command Injection Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage: https://eu3a.mitsubishielectric.com/fa/en/products/cnt/plcccl/items/smartRTU/local Vendor Homepage:...

10CVSS8.4AI score0.5809EPSS
SaveExploits3
exploitpack
exploitpack
added 2019/08/12 12:00 a.m.60 views

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated Configuration Download

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated Configuration Download !/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated Configuration Download Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage:...

5CVSS1.1AI score0.41847EPSS
SaveExploits3
exploitpack
exploitpack
added 2019/08/12 12:00 a.m.90 views

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated OS Command Injection Bind Shell

Mitsubishi Electric smartRTU INEA ME-RTU - Unauthenticated OS Command Injection Bind Shell !/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated OS Command Injection Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage:...

10CVSS1AI score0.5809EPSS
SaveExploits3
Exploit DB
Exploit DB
added 2019/08/12 12:00 a.m.234 views

Mitsubishi Electric smartRTU / INEA ME-RTU - Unauthenticated Configuration Download

!/usr/bin/python Exploit Title: Mitsubishi Electric smartRTU & INEA ME-RTU Unauthenticated Configuration Download Date: 29 June 2019 Exploit Author: @xerubus | mogozobo.com Vendor Homepage: https://eu3a.mitsubishielectric.com/fa/en/products/cnt/plcccl/items/smartRTU/local Vendor Homepage:...

7.5CVSS7.3AI score0.41847EPSS
SaveExploits3
BDU FSTEC
BDU FSTEC
added 2019/06/18 12:00 a.m.13 views

The vulnerability of the RTU module’s microprogramming software, Modicon BMXNOR0200H, arises from the presence of embedded authentication data. This allows a hacker to gain access to the FTP service.

The vulnerability of the RTU module’s microprogramming software, Modicon BMXNOR0200H, is related to the presence of embedded authentication data. Exploiting this vulnerability could allow a malicious actor to gain access to the FTP service remotely...

7.2CVSS5.5AI score0.01143EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.35 views

Honeywell 900TCK-0200 RTU Detection

Binary data 750946.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.15 views

Schneider Electric ION7650 RTU Detection

Binary data 761859.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.13 views

Schneider Electric ION7650 RTU Detection

Binary data 761966.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.11 views

Schneider Electric ION7650 RTU Detection

Binary data 761837.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.17 views

Schneider Electric ION7650 RTU Detection

Binary data 761903.prm...

7.3AI score
SaveExploits0
Rows per page