8 matches found
Exploits_and_Advisories
Exploits e Advisories Repositório que acompanha exploits, vulnerabilidades e advisories públicos que eu co-descobri ou co-escrevi. CVEs CVE| ID| Alvo| Descrição| Divulgação ---|---|---|---|--- CVE-2020-10881| ZDI-20-333| TP-Link Archer A7/C7| estouro de pilha no DNS| Pwn2Own Tokyo 2019...
Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution
This module requires Metasploit: https://metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework class MetasploitModule 'Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution', 'Description' = %q This module exploits a series of vulnerabilities to...
Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution Exploit
This Metasploit module exploits a series of vulnerabilities to achieve unauthenticated remote code execution on the Rockwell FactoryTalk View SE SCADA product as the IIS user. The attack relies on the chaining of five separate vulnerabilities. The first vulnerability is an unauthenticated project...
Inductive Automation Ignition - Remote Code Execution
This Metasploit module exploits a Java deserialization vulnerability in the Inductive Automation Ignition SCADA... This module requires Metasploit: https://metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework class MetasploitModule 'Inductive Automation Ignition...
Inductive Automation Ignition Remote Code Execution Exploit
This Metasploit module exploits a Java deserialization vulnerability in the Inductive Automation Ignition SCADA product, versions 8.0.0 to and including 8.0.7. This exploit was tested on versions 8.0.0 and 8.0.7 on both Linux and Windows. The default configuration is exploitable by an...
Inductive Automation Ignition Remote Code Execution
This module requires Metasploit: https://metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework class MetasploitModule 'Inductive Automation Ignition Remote Code Execution', 'Description' = %q This module exploits a Java deserialization vulnerability in the Inducti...
Rockwell FactoryTalk View SE SCADA Unauthenticated Remote Code Execution
This module exploits a series of vulnerabilities to achieve unauthenticated remote code execution on the Rockwell FactoryTalk View SE SCADA product as the IIS user. The attack relies on the chaining of five separate vulnerabilities. The first vulnerability is an unauthenticated project copy...
Zero Day Initiative Bug Hunters Rake in $1.5M in 2019