Positive Technologies
Positive Technologies
added 2024/03/06 12:00 a.m.28 views

PT-2024-22141

Name of the Vulnerable Software and Affected Versions RSSHub versions 1.0.0-master.cbbd829 through 1.0.0-master.d8ca915 Description RSSHub is an open source RSS feed generator. When a specially crafted image is supplied to the internal media proxy, it proxies the image without handling XSS...

6.1CVSS6.2AI score0.00521EPSS
SaveExploits0References9
CNNVD
CNNVD
added 2023/12/14 12:00 a.m.9 views

Kubeflow Code Issues Vulnerabilities

Kubeflow is a cloud-native platform open-sourced by Kubeflow. A code issue vulnerability exists in Kubeflow that stems from the fact that any user can use Kubeflow as a proxy to access internal and external resources and return the requested response to the user...

7.7CVSS7AI score0.00605EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
added 2023/12/10 12:00 a.m.8 views

PT-2023-31567 · Caddy · Caddy-Geo-Ip

Name of the Vulnerable Software and Affected Versions: caddy-geo-ip versions 0.6.0 and earlier for Caddy 2 Description: The issue allows attackers to spoof their source IP address via an X-Forwarded-For header, which may bypass a protection mechanism, such as the trusted proxy directive in revers...

6.5CVSS6.2AI score0.00655EPSS
SaveExploits0References12
Positive Technologies
Positive Technologies
added 2023/11/22 12:00 a.m.10 views

PT-2023-7559 · Zoho · Zoho Manageengine Recovery Manager Plus

Name of the Vulnerable Software and Affected Versions: Zoho ManageEngine RecoveryManager Plus versions prior to 6070 Description: The issue allows admin users to execute arbitrary commands via proxy settings. This is due to a failure to neutralize special elements, which can be exploited by a...

8.3CVSS7.4AI score0.82163EPSS
SaveExploits0References5
Citrix
Citrix
added 2023/08/20 12:00 a.m.10 views

WEM Service : Unable to connect to the Citrix WEM cloud connectors

Unable to refresh the cache of the WEM agent which uses proxy for Internet access Cache refresh is possible on the WEM agent with direct Internet access...

7.1AI score
SaveExploits0
OSV
OSV
added 2023/05/22 4:15 p.m.9 views

CVE-2023-2588

Teltonika’s Remote Management System versions prior to 4.10.0 have a feature allowing users to access managed devices’ local secure shell SSH/web management services over the cloud proxy. A user can request a web proxy and obtain a URL in the Remote Management System cloud subdomain. This URL cou...

8.8CVSS8.1AI score0.01121EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2022/09/14 12:00 a.m.8 views

PT-2022-23368 · Osu Open Source · Vncauthproxy

Name of the Vulnerable Software and Affected Versions: OSU Open Source Lab VNCAuthProxy versions 1.1.1 and earlier Description: The issue is an authentication-bypass vulnerability in the VNCServerAuthenticator, located in vncap/vnc/protocol.py, which could allow a malicious actor to gain...

9.8CVSS7.1AI score0.01749EPSS
SaveExploits1References14
OSV
OSV
added 2022/02/01 11:15 a.m.4 views

DEBIAN-CVE-2020-8562

As mitigations to a report from 2019 and CVE-2020-8555, Kubernetes attempts to prevent proxied connections from accessing link-local or localhost networks when making user-driven connections to Services, Pods, Nodes, or StorageClass service providers. As part of this mitigation Kubernetes does a...

3.1CVSS6.1AI score0.01082EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2021/12/08 12:00 a.m.12 views

Fortinet FortiWeb安全漏洞

Fortinet FortiWeb is a web application layer firewall from Fortinet that blocks threats such as cross-site scripting, SQL injection, cookie poisoning, schema poisoning and other attacks, secures web applications and protects sensitive database content. fortinet FortiWeb A security vulnerability...

6.5CVSS5.7AI score0.00807EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2021/09/07 7:15 p.m.8 views

CVE-2021-39195

Misskey is an open source, decentralized microblogging platform. In affected versions a Server-Side Request Forgery vulnerability exists in "Upload from URL" and remote attachment handling. This could result in the disclosure of non-public information within the internal network. This has been...

7.7CVSS6.6AI score0.01062EPSS
SaveExploits0References4Affected Software1
Kubernetes Security Advisories
Kubernetes Security Advisories
added 2021/04/26 7:18 p.m.11 views

Bypass of Kubernetes API Server proxy TOCTOU

CVSS Rating: Low CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N A security issue was discovered in Kubernetes where an authorized user may be able to access private networks on the Kubernetes control plane components. Kubernetes clusters are only affected if an untrusted user can create or modify...

3.5CVSS6.4AI score0.01082EPSS
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2020/04/16 12:00 a.m.23 views

Atlassian OAuth Plugin 1.3.0 < 1.9.12 / 2.0.0 < 2.0.4 Server-Side Request Forgery

Atlassian OAuth Plugin from version 1.3.0 to 1.9.11 and from version 2.0.0 to 2.0.3 allows remote attackers to make the target application act as a proxy and perform requests to internal or external resources through the IconUriServlet. Attackers may leverage this vulnerability to conduct...

6.1CVSS6.6AI score0.71601EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.15 views

Rockwell Automation 1798 - 8 Point 24V DC Input, Sink 1798-IB8/A Adapter I/O accessed via proxy

Binary data 754527.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.10 views

Rockwell Automation 1790 16 Universal Input 1790-16BV0X Adapter I/O Accessed Via Proxy

Binary data 754532.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.19 views

Rockwell Automation 1798 - 4 Channel 24V DC Non-Isolated Voltage/Current Analog Input 1798-IE4/A Adapter I/O accessed via proxy

Binary data 754530.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.18 views

Rockwell Automation 1798 - 4 Point 24V DC Input, Sink 1798-IB4/A Adapter I/O accessed via proxy

Binary data 754526.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.16 views

Rockwell Automation 1798 - 4 Point 24V DC Output, Source 1798-OB4E/A Adapter I/O accessed via proxy

Binary data 754528.prm...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.8 views

Rockwell Automation 1790 8 Universal In/8 Out 1790-8BV8BX/8BV8VX Adapter I/O Accessed Via Proxy

Binary data 754535.prm...

7.3AI score
SaveExploits0References1
OSV
OSV
added 2018/09/12 4:29 p.m.9 views

CVE-2018-7572

Pulse Secure Client 9.0R1 and 5.3RX before 5.3R5, when configured to authenticate VPN users during Windows Logon, can allow attackers to bypass Windows authentication and execute commands on the system with the privileges of Pulse Secure Client. The attacker must interrupt the client's network...

6.8CVSS5.9AI score0.00364EPSS
SaveExploits0References1
OSV
OSV
added 2015/09/28 8:59 p.m.7 views

UBUNTU-CVE-2015-5400

Squid before 3.5.6 does not properly handle CONNECT method peer responses when configured with cachepeer, which allows remote attackers to bypass intended restrictions and gain access to a backend proxy via a CONNECT request...

6.8CVSS7AI score0.20844EPSS
SaveExploits1References4