28539 matches found
CVE-2026-25787
Affected devices do not properly validate and sanitize Technology Object TO name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...
CVE-2026-25787
Affected devices do not properly validate and sanitize Technology Object TO name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...
CVE-2026-25786
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a...
CVE-2026-25786
CVE-2026-25786 affects devices where the web interface’s communication parameters page renders a PLC/station name. The root cause is inadequate validation/sanitization of the name, enabling an authenticated user (who is allowed to download a TIA project) to inject malicious scripts into the page....
CVE-2026-25786
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a...
@uipath/project-packager (>=1.1.10 <=1.1.15), @uipath/solution-packager (>=0.0.30 <=0.0.34) potentially affected by unknown CVE via @uipath/solutionpackager-tool-core (>=0.0.31 <=0.0.33)
@uipath/solutionpackager-tool-core NPM version =0.0.31, =1.1.10, =0.0.30, =0.0.34 Source cves: unknown CVE Source advisory: OSV:MAL-2026-3577...
@uipath/solution-packager (>=0.0.30 <=0.0.34) potentially affected by unknown CVE via @uipath/project-packager (>=1.1.10 <=1.1.15)
@uipath/project-packager NPM version =1.1.10, =0.0.30, =0.0.34 Source cves: unknown CVE Source advisory: OSV:MAL-2026-3567...
Malicious code in @uipath/project-packager (npm)
--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware fdd50cfa0aae7619d6766f47b468fca17a04673407486d5c747f860c0c2e22b7 Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...
MAL-2026-3567 Malicious code in @uipath/project-packager (npm)
--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware fdd50cfa0aae7619d6766f47b468fca17a04673407486d5c747f860c0c2e22b7 Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...
Malicious code in @opensearch-project/opensearch (npm)
--- -= Per source details. Do not edit below this line.=- Source: amazon-inspector 1668370f4091d14b4e74ad0e9b25c70ccbc5bf7fb7d97f535212ce2289e71347 The package @opensearch-project/opensearch was found to contain malicious code. Source: ghsa-malware...
omec-project amf crashes when processing malformed LocationReports
A flaw has been found in omec-project amf up to 2.1.1. This vulnerability affects unknown code of the component NGAP Message Handler. Executing a manipulation can lead to memory corruption. The attack can be launched remotely. The exploit has been published and may be used. This patch is called...
GHSA-3H63-FX68-X5FM omec-project amf crashes when processing malformed LocationReports
A flaw has been found in omec-project amf up to 2.1.1. This vulnerability affects unknown code of the component NGAP Message Handler. Executing a manipulation can lead to memory corruption. The attack can be launched remotely. The exploit has been published and may be used. This patch is called...
CVE-2026-8349
A flaw has been found in omec-project amf up to 2.1.1. This vulnerability affects unknown code of the component NGAP Message Handler. Executing a manipulation can lead to memory corruption. The attack can be launched remotely. The exploit has been published and may be used. This patch is called...
PT-2026-40442
PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups...
CVE-2026-31226
CVE-2026-31226 relates to a critical command-injection in TinyZero’s HDFS file operations utilities. The flaw stems from unsafe shell command construction and execution via os.system(), where user-controlled input (e.g., file paths) is interpolated using f-strings inside the _copy() function. An ...
PT-2026-39984
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a...
PT-2026-39985
Affected devices do not properly validate and sanitize Technology Object TO name rendered on the "Motion Control Diagnostics" page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the...
Convolutional-Neural-Networks for Deanonymisation of I2P Traffic
This study investigates the potential for deanonymizing services within the Invisible Internet Project I2P network through passive traffic analysis and machine learning techniques. The primary objective is to identify distinctive patterns in I2P traffic despite the encryption of its payload. To...
CVE-2026-31217
The loadmodel function in the neuralmagictraining.py script of the optimate project in commit a6d302f912b481c94370811af6b11402f51d377f 2024-07-21 allows arbitrary code execution. When a user supplies a directory path via the --model command-line argument, the function reads a module.py file from...
CVE-2026-31225
The superduper project thru v0.10.0 contains a critical remote code execution vulnerability in its query parsing component. The parseoppart function in query.py uses the unsafe eval function to dynamically evaluate user-supplied query operands without proper sanitization or restriction. Although...