added 2025/10/03 8:7 p.m.2 views

EUVD-2022-30282

Malicious code in bioql PyPI...

7.5CVSS7.5AI score0.00145EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/03 8:7 p.m.1 views

EUVD-2024-47299

Malicious code in bioql PyPI...

5.1CVSS6.6AI score0.00074EPSS
Exploits0References1
CNNVD
CNNVD
added 2025/05/07 12:0 a.m.2 views

RT-Labs P-Net 安全漏洞

RT-Labs P-Net is an open source PROFINET protocol stack from RT-Labs that enables standard communication between industrial devices and PROFINET controllers. A security vulnerability exists in RT-Labs P-Net version 1.0.1 and prior versions, which can be exploited by an attacker to cause an IO...

7.5CVSS6.8AI score0.00368EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2025/02/04 11:34 p.m.2 views

CVE-2024-48989

A vulnerability in the PROFINET stack implementation of the IndraDrive all versions of Bosch Rexroth allows an attacker to cause a denial of service, rendering the device unresponsive by sending arbitrary UDP messages...

7.5CVSS7AI score0.00268EPSS
Exploits0
CVE
CVE
added 2024/11/13 1:39 p.m.40 views

CVE-2024-48989

The CVE-2024-48989 affects Bosch Rexroth IndraDrive PROFINET stack (IndraDrive devices, all versions) with a vulnerability in the PROFINET stack that enables an attacker to cause a denial-of-service by sending arbitrary UDP messages, rendering the device unresponsive. Practical impact and exploit...

7.5CVSS7.1AI score0.00268EPSS
Exploits0References1
NVD
NVD
added 2024/10/10 1:15 p.m.8 views

CVE-2024-6157

An attacker who successfully exploited these vulnerabilities could cause the robot to stop. A vulnerability exists in the PROFINET stack included in the RobotWare versions listed below. This vulnerability arises under specific condition when specially crafted message is processed by the system...

5.1CVSS0.00074EPSS
Exploits0References1
Vulnrichment
Vulnrichment
added 2024/10/10 12:21 p.m.8 views

CVE-2024-6157

An attacker who successfully exploited these vulnerabilities could cause the robot to stop. A vulnerability exists in the PROFINET stack included in the RobotWare versions listed below. This vulnerability arises under specific condition when specially crafted message is processed by the system...

5.1CVSS6.8AI score0.00074EPSS
Exploits0References1
Cvelist
Cvelist
added 2024/10/10 12:21 p.m.10 views

CVE-2024-6157

An attacker who successfully exploited these vulnerabilities could cause the robot to stop. A vulnerability exists in the PROFINET stack included in the RobotWare versions listed below. This vulnerability arises under specific condition when specially crafted message is processed by the system...

5.1CVSS0.00074EPSS
Exploits0References1
OSV
OSV
added 2022/04/12 9:15 a.m.0 views

CVE-2022-25622

The PROFINET PNIO stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by...

7.5CVSS7.1AI score
Exploits0References2
NVD
NVD
added 2022/04/12 9:15 a.m.10 views

CVE-2022-25622

The PROFINET PNIO stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by...

7.5CVSS0.00145EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2022/04/12 12:0 a.m.3 views

PT-2022-3546 · Profinet · Profinet

Name of the Vulnerable Software and Affected Versions: PROFINET PNIO stack versions affected versions not specified Description: The issue is related to the improper handling of internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an...

7.5CVSS6.9AI score0.00145EPSS
Exploits0References6
CNNVD
CNNVD
added 2022/04/12 12:0 a.m.4 views

Siemens SIMATIC 资源管理错误漏洞

The SIMATIC S7-400 CPU series is designed for process control in industrial environments.The SIMATIC S7-300 CPU series is designed for discrete and continuous control in industrial environments.The SIMATIC S7-1500 CPU series is designed for discrete and continuous control in industrial...

7.5CVSS5.7AI score0.00145EPSS
Exploits0References7
OSV
OSV
added 2020/12/17 11:15 p.m.0 views

CVE-2020-12521

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...

6.5CVSS6.6AI score0.00084EPSS
Exploits0References1
NVD
NVD
added 2020/12/17 11:15 p.m.9 views

CVE-2020-12521

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...

6.5CVSS6.3AI score0.00084EPSS
Exploits0References1
Prion
Prion
added 2020/12/17 11:15 p.m.8 views

Design/Logic Flaw

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...

6.1CVSS6.4AI score0.00084EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2020/12/17 10:43 p.m.10 views

CVE-2020-12521 Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: A specially crafted LLDP packet may lead to a high system load in the PROFINET stack.

On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot...

6.5CVSS6.4AI score0.00084EPSS
Exploits0References1
CNNVD
CNNVD
added 2020/12/17 12:0 a.m.3 views

Phoenix Contact PLCnext Control Devices 输入验证错误漏洞

Phoenix Contact PLCnext Control Devices is a programmable logic controller for industrial environments from Phoenix Contact. An input validation error vulnerability exists in Phoenix Contact PLCnext Control Devices prior to version 2021.0 LTS, which stems from a specially designed LLDP packet tha...