Lucene search
K

99 matches found

BDU FSTEC
BDU FSTEC
added 2024/02/13 12:0 a.m.4 views

The vulnerabilities of the microprogramming software for Schneider Electric Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58*S, and M580 CPU Safety BMEH58*S, as well as the programming tools EcoStruxure Control Expert and EcoStruxure Process Expert, allow a attacker to execute a “man-in-the-middle” attack.

The vulnerability of microprogrammed logic controllers PLCs from Schneider Electric, such as the Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58S, and M580 CPU Safety BMEH58S, as well as the PLC programming software EcoStruxure Control Expert and EcoStruxure Process...

8.1CVSS7.4AI score0.00314EPSS
Exploits0References2Affected Software4
Positive Technologies
Positive Technologies
added 2024/02/13 12:0 a.m.7 views

PT-2024-1606 · Schneider Electric · M580 Cpu Bmeh +4

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58S, M580 CPU Safety BMEH58S versions affected versions not specified EcoStruxure Control Expert versions affected versions not specified EcoStruxur...

8.1CVSS7.3AI score0.00314EPSS
Exploits0References7
BDU FSTEC
BDU FSTEC
added 2023/06/28 12:0 a.m.7 views

The vulnerabilities of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—allow attackers to induce malfunctions in the equipment.

The vulnerability of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—is related to the...

6.8CVSS7.3AI score0.00832EPSS
Exploits0References3Affected Software3
BDU FSTEC
BDU FSTEC
added 2023/06/28 12:0 a.m.7 views

The vulnerabilities of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—allow a hacker to trigger malfunctions during maintenance operations.

The vulnerability of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—is related to the...

7.8CVSS7.2AI score0.00929EPSS
Exploits0References3Affected Software2
BDU FSTEC
BDU FSTEC
added 2023/06/28 12:0 a.m.6 views

The vulnerabilities of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—allow a hacker to trigger malfunctions during maintenance operations.

The vulnerability of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—is related to reading...

6.8CVSS7.2AI score0.00832EPSS
Exploits0References3Affected Software2
BDU FSTEC
BDU FSTEC
added 2023/05/22 12:0 a.m.6 views

The vulnerability of the programming software for PLCs (programmable logic controllers), namely EcoStruxure Control Expert, and the automation system for technological processes, EcoStruxure Process Expert, allows a intruder to gain unauthorized access to SMTP account data.

The vulnerability of the programming software for PLCs programmable logic controllers, as well as the EcoStruxure Process Expert automation system, is related to insufficient protection for registration data. Exploiting this vulnerability could allow attackers to gain unauthorized access to SMTP...

6.2CVSS5.9AI score0.00236EPSS
Exploits0References5Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/05/22 12:0 a.m.5 views

The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert allows a intruder to trigger maintenance failures.

The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert lies in the storage of data beyond the buffer boundaries. Exploiting this vulnerability could allow a malicious actor to trigger service...

6.8CVSS7.1AI score0.00832EPSS
Exploits0References3Affected Software3
BDU FSTEC
BDU FSTEC
added 2023/03/28 12:0 a.m.6 views

The vulnerabilities of the programming software for PLCs (programmable logic controllers), the configuration software SCADAPack RemoteConnect, and the automation system for technological processes EcoStruxure Process Expert allow a intruder to gain unauthorized access to project files.

The vulnerabilities of the programming software for PLCs programmable logic controllers, the configuration software SCADAPack RemoteConnect, and the automation system for technological processes EcoStruxure Process Expert are related to insufficient protection of registration data. Exploiting the...

8.6CVSS7.1AI score0.00216EPSS
Exploits0References5
Tenable Nessus
Tenable Nessus
added 2023/03/09 12:0 a.m.41 views

Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU Authentication Bypass By Capture-Replay (CVE-2022-45789)

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert Versions pri...

9.8CVSS8.9AI score0.01443EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2023/03/09 12:0 a.m.34 views

Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2022-45788)

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

9.8CVSS9AI score0.01163EPSS
Exploits0References3
NVD
NVD
added 2023/01/31 6:15 a.m.28 views

CVE-2022-45789

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert All Versions...

9.8CVSS9AI score0.01443EPSS
Exploits0References1
ATTACKERKB
ATTACKERKB
added 2023/01/31 6:15 a.m.4 views

CVE-2022-45789

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert All Versions...

9.8CVSS7.6AI score0.01443EPSS
Exploits0References2
Prion
Prion
added 2023/01/31 6:15 a.m.24 views

Authentication flaw

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert All Versions...

7.5CVSS9.3AI score0.01443EPSS
Exploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2023/01/31 12:0 a.m.11 views

CVE-2022-45789

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert All Versions...

8.1CVSS9.4AI score0.01443EPSS
Exploits0References1
CVE
CVE
added 2023/01/31 12:0 a.m.98 views

CVE-2022-45789

CVE-2022-45789 is a concrete vulnerability in Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, Modicon M340/M580 CPUs (and variants) where an authenticated Modbus session can be hijacked to bypass authentication and execute unauthorized Modbus functions. Root cause: CWE-...

9.8CVSS9.3AI score0.01443EPSS
Exploits0References1Affected Software2
OSV
OSV
added 2023/01/30 1:15 p.m.3 views

CVE-2022-45788

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

9.8CVSS6AI score
Exploits0References1
ATTACKERKB
ATTACKERKB
added 2023/01/30 1:15 p.m.4 views

CVE-2022-45788

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

9.8CVSS7.7AI score0.01163EPSS
Exploits0References2
NVD
NVD
added 2023/01/30 1:15 p.m.30 views

CVE-2022-45788

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

9.8CVSS8.9AI score0.01163EPSS
Exploits0References1
Prion
Prion
added 2023/01/30 1:15 p.m.21 views

Design/Logic Flaw

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

7.5CVSS9.5AI score0.01163EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2023/01/30 12:0 a.m.23 views

CVE-2022-45788

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...

7.5CVSS9.7AI score0.01163EPSS
Exploits0References1
Rows per page
Query Builder