108 matches found
Schneider Electric ProClima Version Detection
Binary data 9047.prm...
Schneider Electric ProClima Application Detection
Binary data 9048.prm...
Schneider Electric ProClima Denial of Service Vulnerability
Schneider Electric ProClima is a thermal calculation software from Schneider Electric France. A denial of service vulnerability exists in Schneider Electric ProClima versions prior to 6.2. It allows remote attackers to execute arbitrary code or cause a denial of service via a crafted integer valu...
CVE-2015-8561
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service memory corruption via a crafted integer value to the 1 AttachToSS, 2 CopyAll, 3 CopyRange, 4 CopyRangeEx, or 5 SwapTable method, a...
CVE-2015-7918
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the 1 Attach, 2 DefinedName, 3 DefinedNameLocal, 4 ODBCPrepareEx, 5 ObjCreatePolygon, 6 SetTabbedTextEx, or 7 SetValidationRule...
CVE-2015-7918
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the 1 Attach, 2 DefinedName, 3 DefinedNameLocal, 4 ODBCPrepareEx, 5 ObjCreatePolygon, 6 SetTabbedTextEx, or 7 SetValidationRule...
Buffer overflow
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the 1 Attach, 2 DefinedName, 3 DefinedNameLocal, 4 ODBCPrepareEx, 5 ObjCreatePolygon, 6 SetTabbedTextEx, or 7 SetValidationRule...
Memory corruption
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service memory corruption via a crafted integer value to the 1 AttachToSS, 2 CopyAll, 3 CopyRange, 4 CopyRangeEx, or 5 SwapTable method, a...
CVE-2015-8561
The connected sources confirm CVE-2015-8561 affects Schneider Electric ProClima’s F1BookView ActiveX control (F1 Bookview) in versions before 6.2. The vulnerability is described as a memory corruption issue that could allow remote code execution or a denial of service when a crafted integer is su...
CVE-2015-7918
The F1BookView ActiveX control in Schneider Electric ProClima before 6.2 contains multiple buffer overflows that can be triggered via the methods Attach, DefinedName, DefinedNameLocal, ODBCPrepareEx, ObjCreatePolygon, SetTabbedTextEx, and SetValidationRule, enabling remote code execution. This vu...
CVE-2015-7918
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the 1 Attach, 2 DefinedName, 3 DefinedNameLocal, 4 ODBCPrepareEx, 5 ObjCreatePolygon, 6 SetTabbedTextEx, or 7 SetValidationRule...
CVE-2015-8561
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service memory corruption via a crafted integer value to the 1 AttachToSS, 2 CopyAll, 3 CopyRange, 4 CopyRangeEx, or 5 SwapTable method, a...
CVE-2015-8561: Improper Restriction of Operations within the Bounds of a Memory Buffer
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service memory corruption via a crafted integer value to the 1 AttachToSS, 2 CopyAll, 3 CopyRange, 4 CopyRangeEx, or 5 SwapTable method, a...
CVE-2015-7918: Improper Restriction of Operations within the Bounds of a Memory Buffer
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the 1 Attach, 2 DefinedName, 3 DefinedNameLocal, 4 ODBCPrepareEx, 5 ObjCreatePolygon, 6 SetTabbedTextEx, or 7 SetValidationRule...
PT-2015-7806
Name of the Vulnerable Software and Affected Versions Schneider Electric ProClima versions prior to 6.2 Description The issue allows remote attackers to execute arbitrary code or cause a denial of service due to memory corruption. This can be achieved by providing a crafted integer value to certa...
Schneider Electric ProClima F1BookView ActiveX Control SetTabbedTextEx Method Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the...
Schneider Electric ProClima F1BookView ActiveX Control SetValidationRule Method Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the...
Schneider Electric ProClima F1BookView ActiveX Control AttachToSS Method Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the...
Schneider Electric ProClima F1BookView ActiveX Control CopyAll Method Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the...
Schneider Electric ProClima F1BookView ActiveX Control CopyRange/SwapTables Methods Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaws exist within the...