89 matches found
CVE-2024-28042: Reliance on Insufficiently Trustworthy Component
SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center...
PT-2024-22232 · Unknown · Powersystem Center
Name of the Vulnerable Software and Affected Versions: PowerSYSTEM Center affected versions not specified Description: The issue concerns vulnerabilities in third-party components used in PowerSYSTEM Center. No specific details about the nature of the vulnerabilities, affected devices, or...
SUBNET PowerSYSTEM Center
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION : Low attack complexity Vendor : Subnet Solutions Inc. Equipment : PowerSYSTEM Center Vulnerabilities : Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by...
SUBNET PowerSYSTEM Center 安全漏洞
SUBNET PowerSYSTEM Center is SUBNET's infrastructure for secure, centralized management of the many different intelligent electronic devices meters, relays, RTUs, etc. deployed throughout the transmission and distribution system. A security vulnerability exists in SUBNET PowerSYSTEM Server 2021,...
CVE-2023-6631
PowerSYSTEM Center versions 2020 Update 16 and prior contain a vulnerability that may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges...
Design/Logic Flaw
PowerSYSTEM Center versions 2020 Update 16 and prior contain a vulnerability that may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges...
CVE-2023-6631 Subnet Solutions Inc. PowerSYSTEM Center Unquoted Search Path or Element
PowerSYSTEM Center versions 2020 Update 16 and prior contain a vulnerability that may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges...
CVE-2023-6631
CVE-2023-6631 affects Subnet Solutions PowerSYSTEM Center (PowerSYSTEM Center 2020 Update 16 and earlier; 5.0.x–5.16.x). The vulnerability is an unquoted search path/element in the service path that authorized local users can abuse to insert arbitrary code and achieve privilege escalation. Affect...
CVE-2023-6631 Subnet Solutions Inc. PowerSYSTEM Center Unquoted Search Path or Element
PowerSYSTEM Center versions 2020 Update 16 and prior contain a vulnerability that may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges...
SUBNET PowerSYSTEM Center Code Issue Vulnerability
SUBNET PowerSYSTEM Center is SUBNET's infrastructure for securely and centrally managing the many different intelligent electronic devices meters, relays, RTUs, etc. deployed throughout the transmission and distribution system. A security vulnerability exists in SUBNET PowerSYSTEM Center 2020...
PT-2024-15033 · Unknown · Powersystem Center
Name of the Vulnerable Software and Affected Versions: PowerSYSTEM Center versions 2020 Update 16 and prior Description: The issue allows an authorized local user to insert arbitrary code into the unquoted service path, potentially leading to privilege escalation. Recommendations: For PowerSYSTEM...
CVE-2023-6631: Unquoted Search Path or Element
PowerSYSTEM Center versions 2020 Update 16 and prior contain a vulnerability that may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges...
Subnet Solutions Inc. PowerSYSTEM Center
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center Vulnerability: Unquoted Search Path or Element 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker achieving arbitrary...
CVE-2023-29158
SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity...
CVE-2023-32659
SUBNET PowerSYSTEM Center versions 2020 U10 and prior contain a cross-site scripting vulnerability that may allow an attacker to inject malicious code into report header graphic files that could propagate out of the system and reach users who are subscribed to email notifications...
CVE-2023-32659
SUBNET PowerSYSTEM Center versions 2020 U10 and prior contain a cross-site scripting vulnerability that may allow an attacker to inject malicious code into report header graphic files that could propagate out of the system and reach users who are subscribed to email notifications...
Race condition
SUBNET PowerSYSTEM Center versions 2020 U10 and prior are vulnerable to replay attacks which may result in a denial-of-service condition or a loss of data integrity...
Cross site scripting
SUBNET PowerSYSTEM Center versions 2020 U10 and prior contain a cross-site scripting vulnerability that may allow an attacker to inject malicious code into report header graphic files that could propagate out of the system and reach users who are subscribed to email notifications...
CVE-2023-32659 SUBNET PowerSYSTEM Center Cross-site Scripting
SUBNET PowerSYSTEM Center versions 2020 U10 and prior contain a cross-site scripting vulnerability that may allow an attacker to inject malicious code into report header graphic files that could propagate out of the system and reach users who are subscribed to email notifications...
CVE-2023-32659
SUBNET PowerSYSTEM Center (PowerSYSTEM Center) versions 2020 U10 and prior are affected by CVE-2023-32659, a cross-site scripting (CWE-79) vulnerability in report header graphic file handling. The issue arises from improper input neutralization during web page generation, enabling an attacker to ...