Lucene search
+L

66 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/24 12:00 a.m.•4 views

CVE-2024-4114: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has...

9CVSS6.3AI score0.01349EPSS
SaveExploits0References3
NVD
NVD
•added 2024/02/21 9:15 p.m.•24 views

CVE-2023-24332

A stack overflow vulnerability in Tenda AC6 with firmware version USAC6V5.0reV03.03.02.01cnTDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet...

8.1CVSS7.3AI score0.0055EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/02/21 12:00 a.m.•3 views

CVE-2023-24332: Stack-based Buffer Overflow

A stack overflow vulnerability in Tenda AC6 with firmware version USAC6V5.0reV03.03.02.01cnTDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet...

8.1CVSS6.1AI score0.0055EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2024/02/21 12:00 a.m.•7 views

PT-2024-12027

Name of the Vulnerable Software and Affected Versions Tenda AC6 version US AC6V5.0re V03.03.02.01 cn TDC01 Description A stack overflow issue allows attackers to run arbitrary commands via a crafted POST request to "/goform/PowerSaveSet". This can be exploited by sending a specifically designed...

8.1CVSS6AI score0.0055EPSS
SaveExploits1References5
NVD
NVD
•added 2023/08/30 1:15 p.m.•22 views

CVE-2023-41562

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet...

9.8CVSS9.8AI score0.00838EPSS
SaveExploits1References1
Prion
Prion
•added 2023/08/30 1:15 p.m.•27 views

Stack overflow

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet...

7.5CVSS9.7AI score0.00838EPSS
SaveExploits1References1Affected Software3
CVE
CVE
•added 2023/08/30 12:00 a.m.•71 views

CVE-2023-41562

CVE-2023-41562 affects Tenda routers: AC7 v1.0 (V15.03.06.44), AC9 v3.0 (V15.03.06.42_multi), and AC5 (US_AC5V1.0RTL_V15.03.06.28). The vulnerability is a stack overflow triggered by the time parameter in the /goform/PowerSaveSet API. The NVD entry assigns a CVSS v3.1 base score of 9.8 (CRITICAL)...

9.8CVSS9.7AI score0.00838EPSS
SaveExploits1References1Affected Software1
Vulnrichment
Vulnrichment
•added 2023/08/30 12:00 a.m.•21 views

CVE-2023-41562

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet...

7.9AI score0.00838EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
•added 2023/08/30 12:00 a.m.•16 views

PT-2023-27980 · Tenda · Tenda Ac7 +2

Name of the Vulnerable Software and Affected Versions: Tenda AC7 version 1.0 V15.03.06.44 Tenda AC9 version 3.0 V15.03.06.42 multi Tenda AC5 version US AC5V1.0RTL V15.03.06.28 Description: A stack overflow issue was discovered via the time parameter at the "/goform/PowerSaveSet" API endpoint. Thi...

9.8CVSS9.3AI score0.00838EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/08/30 12:00 a.m.•5 views

CVE-2023-41562: Out-of-bounds Write

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet...

9.8CVSS8.4AI score0.00838EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2023/08/30 12:00 a.m.•42 views

CVE-2023-41562

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42multi, and Tenda AC5 USAC5V1.0RTLV15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet...

9.9AI score0.00838EPSS
SaveExploits1References1
CNNVD
CNNVD
•added 2023/08/30 12:00 a.m.•20 views

Tenda AC7 缓冲区错误漏洞

Tenda AC7 is a wireless router from Tenda, China. A security vulnerability exists in the Tenda AC7, which is caused by a buffer overflow in the time parameter of /goform/PowerSaveSet...

9.8CVSS8.8AI score0.00838EPSS
SaveExploits1References2
Prion
Prion
•added 2023/08/24 6:15 p.m.•31 views

Stack overflow

Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet...

7.5CVSS9.6AI score0.00928EPSS
SaveExploits1References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/08/24 12:00 a.m.•2 views

CVE-2023-40893: Out-of-bounds Write

Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet...

9.8CVSS8.4AI score0.00928EPSS
SaveExploits1References2
CVE
CVE
•added 2023/08/24 12:00 a.m.•74 views

CVE-2023-40893

CVE-2023-40893 affects Tenda AC8 (v4 US_AC8V4.0si_V16.03.34.06_cn). The vulnerability is a stack overflow triggered by the time parameter to /goform/PowerSaveSet. Public documents describe potential for crashing the application and, in some sources, arbitrary code execution in the application con...

9.8CVSS9.6AI score0.00928EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
•added 2023/08/24 12:00 a.m.•43 views

CVE-2023-40893

Tenda AC8 v4 USAC8V4.0siV16.03.34.06cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet...

9.9AI score0.00928EPSS
SaveExploits1References1
NVD
NVD
•added 2023/06/08 3:15 p.m.•34 views

CVE-2023-34568

Tenda AC10 v4 USAC10V4.0siV16.03.10.13cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet...

6.7CVSS6.7AI score0.00316EPSS
SaveExploits0References1
Prion
Prion
•added 2023/06/08 3:15 p.m.•32 views

Stack overflow

Tenda AC10 v4 USAC10V4.0siV16.03.10.13cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet...

4CVSS6.7AI score0.00316EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2023/06/08 12:00 a.m.•15 views

CVE-2023-34568

Tenda AC10 v4 USAC10V4.0siV16.03.10.13cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet...

6.7AI score0.00316EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2023/06/08 12:00 a.m.•41 views

CVE-2023-34568

Tenda AC10 v4 USAC10V4.0siV16.03.10.13cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet...

6.9AI score0.00316EPSS
SaveExploits0References1
Rows per page
Query Builder