PowerLogic EGX300 is a French Schneider-electric application server an integrated gateway server A security vulnerability exists in PowerLogic's PM55xx, PM8ECC, EGX100, and EGX300 that stems from a weak password recovery from forgotten passwords vulnerability in the PowerLogic PM55xx, PowerLogic...
Schneider Electric PowerLogic 多款产品输入验证错误漏洞
Schneider Electric PowerLogic is an industrial control device from Schneider Electric, France. It provides increased power factor to improve power quality and troubleshoot power failures to protect networks, devices, and operators. An input validation error vulnerability exists in the Schneider...
PT-2021-15205
Name of the Vulnerable Software and Affected Versions PowerLogic EGX100 versions 3.0.0 and newer PowerLogic EGX300 all versions Description A vulnerability exists due to improper input validation, which could cause denial of service or remote code execution via a specially crafted HTTP packet...
PT-2021-15202
Name of the Vulnerable Software and Affected Versions PowerLogic PM55xx affected versions not specified PowerLogic PM8ECC affected versions not specified PowerLogic EGX100 affected versions not specified PowerLogic EGX300 affected versions not specified Description A CWE-287: Improper...
PT-2021-15201
Name of the Vulnerable Software and Affected Versions PowerLogic PM55xx affected versions not specified PowerLogic PM8ECC affected versions not specified PowerLogic EGX100 affected versions not specified PowerLogic EGX300 affected versions not specified Description A Weak Password Recovery...
Unauthorized Access Vulnerability in PowerLogic ION8600 at Schneider Electric (China) Co.
Schneider Electric China Co. Ltd. is a company whose main business includes the business areas of Power, Industrial Automation, Infrastructure, Energy Conservation and Efficiency, Energy, Building Automation and Security Electronics, Data Centers and Smart Living Spaces. An unauthorized access...
Unauthorized Vulnerability in PowerLogic ION7650 for Power Monitoring at Schneider Electric (China) Co.
Schneider Electric China Co. Ltd. is a company whose main businesses include power, industrial automation, infrastructure, energy saving and efficiency, energy, building automation and security electronics, data centers and smart living spaces. An unauthorized vulnerability exists in the PowerLog...
Schneider Electric PowerLogic Buffer Overflow Vulnerability
Schneider Electric PowerLogic is an industrial control device from Schneider Electric, France. It provides increased power factor to improve power quality and troubleshoot power failures to protect networks, devices, and operators. A buffer overflow vulnerability exists in the PowerLogic ION7400,...
Critical Security Bug Can Knock Smart Meters Offline
Critical security vulnerabilities in Schneider Electric smart meters could allow an attacker a path to remote code execution RCE, or to reboot the meter causing a denial-of-service DoS condition on the device. Schneider Electric’s PowerLogic ION/PM smart meter product line, like other smart meter...
CVE-2021-22714
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 All versions prior to V3.0.0, which could cause the meter to reboot or allow for remote code execution...
CVE-2021-22714
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 All versions prior to V3.0.0, which could cause the meter to reboot or allow for remote code execution...
CVE-2021-22713
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...
CVE-2021-22713
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...
Design/Logic Flaw
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...
Design/Logic Flaw
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 All versions prior to V3.0.0, which could cause the meter to reboot or allow for remote code execution...
CVE-2021-22713
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...
CVE-2021-22713
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 see security notifcation for affected versions, which could cause the meter to reboot...
CVE-2021-22713
CVE-2021-22713 affects Schneider Electric PowerLogic meters: PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600. The root cause is a CWE-119 improper restriction of operations within the bounds of a memory buffer, which can cause the meter to reboot. The vulnerability ...
CVE-2021-22714
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 All versions prior to V3.0.0, which could cause the meter to reboot or allow for remote code execution...
CVE-2021-22714
Schneider Electric PowerLogic ION7400, PM8000 and ION9000 (all versions before V3.0.0) are affected by CVE-2021-22714 due to CWE-119 memory-buffer bounds violation. The issue could cause a meter reboot or remote code execution. Remediation: update to firmware V3.0.0 or apply Schneider Electric/SE...